Siemens SB10 Product Information
Siemens SB10 Product Information

Siemens SB10 Product Information

Interface modules for simatic tdc / fm 458-1dp
Table of Contents

Advertisement

Quick Links

Interface modules (for SIMATIC TDC / FM 458-1DP)
Interface modules
(for SIMATIC TDC / FM 458-1DP)
Product Information
04/2024
A5E53479401-AA
Preface
Installation and EMC
guidelines
General technical
specifications
Interface modules
1
2
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SB10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens SB10

  • Page 1 Interface modules (for SIMATIC TDC / FM 458-1DP) Preface Installation and EMC guidelines General technical specifications Interface modules Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information 04/2024 A5E53479401-AA...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    Data protection Siemens respects the principles of data privacy, in particular the data minimization rules (privacy by design). For this SIMATIC product, this means: The product does not process or store any personal data, only technical function data (e.g. time stamps). If a user links this data with other data (e.g.
  • Page 4: Security Information

    This information is provided by the Siemens Industry Online Support in the Internet (https://support.industry.siemens.com). Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
  • Page 5: Table Of Contents

    Electrical protection and safety requirements ..............26 External supply of the SIMATIC TDC / FM458 modules (digital outputs) ....... 26 Mechanical requirements ....................27 Electromagnetic requirements (industry)................27 Interface modules ..........................28 Interface module SB10 ....................... 28 3.1.1 Signals ..........................30 3.1.2 Application notes ....................... 31 3.1.3...
  • Page 6 Table of contents Interface module SB60 ....................... 35 3.2.1 Signals..........................37 3.2.2 Application notes ....................... 37 3.2.3 Technical specifications ..................... 38 3.2.4 Pin assignment ........................39 3.2.5 Block diagram ........................40 Interface module SB61 ....................... 41 3.3.1 Signals..........................42 3.3.2 Application notes .......................
  • Page 7: Installation And Emc Guidelines

    Furthermore, the contents of these Operating Instructions shall not become a part of or modify any prior or existing agreement, commitment, or legal relationship. All obligations on the part of Siemens AG are contained in the respective sales contract which also contains the complete and solely applicable warranty conditions. These contractual guarantee provisions are neither broadened nor restricted by the text in these operating instructions.
  • Page 8: Danger And Warning Information

    Installation and EMC guidelines 1.3 Danger and warning information Danger and warning information WARNING Danger, high voltage During operation of electrical devices, certain parts of these devices are necessarily under dangerous voltage. Ignorance of the safety instructions may result in severe injury or property damage. Particularly the warning notes in the corresponding Operating Instructions must be strictly observed.
  • Page 9: Introduction

    Installation and EMC guidelines 1.4 Introduction Introduction What is EMC ? Electromagnetic compatibility (EMC) is the ability of an electrical device to function, fault-free in a specified electromagnetic environment without influencing the environment in an inadmissible fashion. This design and EMC Directive supplements the documentation on the individual components. The control system SIMATIC TDC / FM458-1DP consists of individual components (e.g.
  • Page 10: Standards, Approvals And Safety Instructions

    Installation and EMC guidelines 1.5 Standards, approvals and safety instructions Standards, approvals and safety instructions Currently valid markings and approvals Note Information on the components of the SIMATIC TDC / FM458-1DP The currently valid markings and approvals are printed on the components of the SIMATIC TDC / FM458-1DP.
  • Page 11 DI FA TI COS TT P.O. Box 1963 D-92209 Amberg The EU declarations of conformity are also available for download from the Siemens Industry Online Support website, under the keyword "Declaration of Conformity". UK Conformity Assessed marking The marked products comply with the designated British Standards (BS) for programmable logic controllers published in the official consolidated list of the British Government.
  • Page 12 Installation and EMC guidelines 1.5 Standards, approvals and safety instructions cULus approval Underwriters Laboratories Inc. in accordance with • UL 508 (Industrial Control Equipment) • CAN/C22.2 No. 142 (Process Control Equipment) cULus HAZ. LOC. approval Underwriters Laboratories Inc. in accordance with •...
  • Page 13 Installation and EMC guidelines 1.5 Standards, approvals and safety instructions ATEX approval According to EN 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") and EN IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General Requirements).
  • Page 14 Installation and EMC guidelines 1.5 Standards, approvals and safety instructions IECEx approval According to IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") and IEC 60079-0 (Explosive atmospheres - Part 0: Equipment - General requirements). Ex nA IIC T4 Gc IECEx DEK 17.0039 X According to IEC 60079-7 (Explosive atmospheres - Part 7: Equipment protection by increased...
  • Page 15: Emc Directive

    Installation and EMC guidelines 1.6 EMC Directive EMC Directive The marked products are designed for use in industrial environments. Industrial environments • Interference emission requirements to EN 61000-6-4: 2007 + A1:2011 • Immunity to interference requirements to EN 61000-6-2: 2005 Low-voltage directive The products listed in the table below fulfill the requirements of EU directive 2014/35/EU, "Low-Voltage Directive".
  • Page 16: Installation

    Installation and EMC guidelines 1.9 Installation Installation SIMATIC TDC / FM458-1DP components are considered open equipment that must be installed in a metallic enclosure with shielding bus and equipotential busbar that meets the requirements of IEC 61131-2 (11.1.2; mechanical strength, flame resistance, stability and touch protection are significant here).
  • Page 17: Schematic Circuit Diagram

    Installation and EMC guidelines 1.12 Equipotential bonding Equipotential busbar An equipotential busbar should be provided in each control cabinet to facilitate wiring. All internal and external components must be interconnected with this equipotential busbar. Schematic circuit diagram Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 18: Practical Application Examples

    Installation and EMC guidelines 1.12 Equipotential bonding Practical application examples Termination of an external shielded cable The shield must be connected to the shielding bus. Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 19 Installation and EMC guidelines 1.12 Equipotential bonding Termination of an external shielded cable with supply via interface module The shield must be connected to the shielding bus. Ground of the external power supply must be wired to the shielding busbar, or to the equipotential busbar.
  • Page 20 Installation and EMC guidelines 1.12 Equipotential bonding Termination of an internal power supply via interface module The shield must be connected to the shielding bus. Ground of the internal power supply must be connected to the shielding busbar, or to the equipotential busbar.
  • Page 21 Installation and EMC guidelines 1.12 Equipotential bonding Example of grounding and potential equalization Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 22: Protective Ground

    The 24 V power supply must also be equipped with lightning/overvoltage protection. For more information, refer to the installation manual "SIMATIC Automation Systems S7-400, Hardware and Installation (http://support.automation.siemens.com/WW/view/en/1117849)". NOTICE Network devices Safe electrical separation according to IEC 61131-2 (11.1.2.1.3) must be ensured for all network devices used to supply power to SIMATIC TDC / FM458-1DP devices and modules.
  • Page 23 Installation and EMC guidelines 1.15 Cables Design and temperature resistance All cables must be made of copper and be able to resist temperatures of up to at least 90 °C. Connection via interface module If interface modules are used, the shields of the plant-side cables and cables from the interface module to SIMATIC TDC / FM458-1DP must be connected directly above or below the interface module.
  • Page 24: Esd Directives

    Installation and EMC guidelines 1.16 ESD Directives 1.16 ESD Directives Almost all of the SIMATIC TDC / FM458-1DP modules contain highly integrated circuits. Due to their technology, these circuits are highly sensitive to overvoltage and, therefore, to ESD. The abbreviation stands for electrostatic discharge Modules equipped with such components are identified by the following warning label on component side: Electrostatic sensitive components can be destroyed by voltages and power levels far below...
  • Page 25 Installation and EMC guidelines 1.16 ESD Directives Measuring and modifying ESD modules • Measurements may only be taken on the modules when – The measuring devices is grounded (e.g. via PE conductor), or – The measuring head has been briefly discharged (e.g. by touching a bright metal part of the control enclosure) prior to measurement with an electrically isolated measuring device.
  • Page 26: General Technical Specifications

    General technical specifications Climatic conditions Table 2- 1 Storage and transport conditions IEC 60721 Part 3-2 Class 2K1, without condensation Storage temperature -40 °C to +70 °C Operating conditions IEC 60721 Part 3-3 Class 3K3, stationary use, weather- protected Operating temperatures 0 °C to +60 °C (air intake temperature) Atmospheric pressure...
  • Page 27: Mechanical Requirements

    General technical specifications 2.4 Mechanical requirements Mechanical requirements The following table provides information on the type and scope of checks regarding mechanical ambient conditions. Tested for Test standard Note Vibrations Vibration test according to Type of vibration: Frequency cycles with a rate of change of IEC 60068-2-6 (sine) 1 octave/minute 10 Hz ≤...
  • Page 28: Interface Modules

    Interface modules Interface module SB10 Article number 6DD1681-0AE2 Description The interface module passes digital signals from SIMATIC TDC / FM458-1DP components to the plant or receives digital signals from the plant and passes them to SIMATIC TDC / FM458- 1DP components. The interface module is connected to SIMATIC TDC / FM458-1DP components via cables SC62 or SC66 and on the plant side via terminals.
  • Page 29 Interface modules 3.1 Interface module SB10 Green LED The SIMATIC TDC / FM458-1DP-side voltage supply is indicated by a green LED (P). Red LED The SIMATIC TDC / FM458-1DP-side voltage supply (1P, 1M) is short-circuited (fault). Test socket By means of the double test socket (G; +), the voltages 1P and 1M can be used to simulate an input signal for SIMATIC TDC / FM458-1DP.
  • Page 30: Signals

    Interface modules 3.1 Interface module SB10 3.1.1 Signals Yellow LED The status of each of the 8 signals (1...8) is displayed by means of a yellow LED. Each signal is provided a screw terminal on the two terminal blocks X2: •...
  • Page 31: Application Notes

    The following figure shows a typical application: Figure 3-2 Application example of an SB10 interface module on the digital I/O module SM500 The plant-side digital signals are connected directly to the SIMATIC TDC / FM458-1DP modules via the interface module. A cable SC62 is used accordingly.
  • Page 32: Technical Specifications

    Interface modules 3.1 Interface module SB10 3.1.3 Technical specifications General data Mounting system Suitable for snap-on mounting on rails Dimensions W x H x D [mm] 45 x 129 x 160 mm Weight 0.3 kg Ambient temperatures Ambient temperatures max. 60 °C...
  • Page 33: Pin Assignment

    The cables SC62 or SC66 are used to connect the interface modules to the SIMATIC TDC / FM458-1DP components. Terminal block X2 Table 3- 1 Pin assignment of the digital I/O of interface module SB10 Terminal Designation Channel 1 (digital input/output 1)
  • Page 34: Block Diagram

    Interface modules 3.1 Interface module SB10 3.1.5 Block diagram Figure 3-3 Block diagram of interface module SB10 Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 35: Interface Module Sb60

    Interface modules 3.2 Interface module SB60 Interface module SB60 Article number 6DD1681-0AF4 Description Interface module SB60 is used to adapt 8 digital input signals with electrical isolation to the signal level of SIMATIC TDC / FM458-1DP by means of an optocoupler. The input signal voltage can amount to 120 V DC or AC.
  • Page 36 Interface modules 3.2 Interface module SB60 Voltage supply on SIMATIC side The SIMATIC TDC / FM458-1DP-side voltage supply is fed to terminal X3: Terminal X3 Voltage on SIMATIC TDC / FM458 side +24 V The cables are connected with the SM11 parts kit "Power supply connector for interface modules"...
  • Page 37: Signals

    Interface modules 3.2 Interface module SB60 3.2.1 Signals Signals up to a maximum of 120 V (nominal value) DC or AC can be connected at the SB60 interface module. Yellow LED The state of the digital outputs of the interface module (digital inputs for SIMATIC TDC / FM458-1DP) is indicated by yellow LEDs (1...8).
  • Page 38: Technical Specifications

    Interface modules 3.2 Interface module SB60 3.2.3 Technical specifications General data Mounting system Suitable for snap-on mounting on rails Dimensions W x H x D [mm] 45 x 129 x 160 mm Weight 0.3 kg Ambient temperatures Ambient temperatures max. 60 °C Power supply Supply voltage (V Rated value...
  • Page 39: Pin Assignment

    Interface modules 3.2 Interface module SB60 3.2.4 Pin assignment Flat connector X1 The cables SC62 or SC66 are used to connect the interface modules to the SIMATIC TDC / FM458-1DP components. Digital inputs terminal block X2 Table 3- 2 Pin assignment of the digital inputs of interface module SB60 Terminal 120 V Channel No.
  • Page 40: Block Diagram

    Interface modules 3.2 Interface module SB60 3.2.5 Block diagram Figure 3-4 Block diagram of interface module SB60 Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 41: Interface Module Sb61

    Interface modules 3.3 Interface module SB61 Interface module SB61 Article number 6DD1681-0EB3 Description Interface module SB61 is used to adapt 8 digital DC signals with electrical isolation to the signal level of SIMATIC TDC / FM458-1DP components. The cables SC62 or SC66 are used to connect the interface modules to the SIMATIC TDC / FM458-1DP components.
  • Page 42: Signals

    Interface modules 3.3 Interface module SB61 3.3.1 Signals Voltage supply on plant side 24/48 V DC is available for the system side signals at terminal block X4: Terminal X4 Voltage on plant side +24/48 V The cables are connected with the SM11 parts kit "Power supply connector for interface modules"...
  • Page 43: Application Notes

    Interface modules 3.3 Interface module SB61 3.3.2 Application notes Plant/system-side signal voltages of 48V or 24V DC can be processed using the interface module. The plant/system side of the module has 8 electrically isolated input channels. Using short-circuit connectors (X11), the connection of each channel can be electrically isolated from one another, or connected to a common reference point: Inputs, electrically isolated Figure 3-5...
  • Page 44 Interface modules 3.3 Interface module SB61 Position of the jumpers The jumpers (short-circuit plugs) are located in enclosure behind the lid section facing away from the LEDs. These are only accessible after the interface module has been removed. The potential assignment between the plant and system side is defined as follows: Table 3- 3 Position of the short-circuit plug (jumper) Reference potential of inputs...
  • Page 45: Technical Specifications

    Interface modules 3.3 Interface module SB61 3.3.3 Technical specifications General data Mounting system The enclosure is suitable for snap-on mounting to rails Dimensions W x H x D [mm] 45 x 129 x 160 mm Weight 0.3 kg Ambient temperatures Ambient temperatures max.
  • Page 46: Pin Assignment

    Interface modules 3.3 Interface module SB61 3.3.4 Pin assignment Flat connector X1 The cables SC62 and SC66 are used to connect the interface modules to the SIMATIC TDC / FM458-1DP components (for more information, refer to the SIMATIC TDC / FM458-1DP documentation).
  • Page 47: Block Diagram

    Interface modules 3.3 Interface module SB61 3.3.5 Block diagram Figure 3-8 Block diagram of interface module SB61 Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 48: Interface Module Sb70

    Interface modules 3.4 Interface module SB70 Interface module SB70 Article number 6DD1681-0AG2 Description Interface module SB70 is used to adapt 8 digital output signals from SIMATIC TDC / FM458- 1DP with electrical isolation to the signal level of the plant by means of relays. The voltage of the output signal may amount up to max.
  • Page 49 Interface modules 3.4 Interface module SB70 Voltage supply on SIMATIC side The SIMATIC TDC voltage supply is fed to terminal X3: Terminal X3 Voltage on SIMATIC TDC / FM458-1DP side +24 V The cables are connected with the SM11 parts kit "Power supply connector for interface modules"...
  • Page 50: Signals

    Interface modules 3.4 Interface module SB70 3.4.1 Signals Yellow LED The status of each of the 8 signals (1...8) is displayed by means of a yellow LED. Terminal block for digital signals Terminal block X2 provides three screw terminals for each signal to the plant side: •...
  • Page 51: Application Notes

    Interface modules 3.4 Interface module SB70 3.4.2 Application notes The interface module is suitable for vertical and horizontal mounting positions Other information For more information on EMC and ambient conditions, refer to section General technical specifications (Page 26). The following figure shows a typical application: Figure 3-9 Application example of an SB70 interface module on digital I/O module SM500 The digital inputs of the interface module are connected to the outputs of SIMATIC TDC /...
  • Page 52: Technical Specifications

    Interface modules 3.4 Interface module SB70 3.4.3 Technical specifications General data Mounting system Housing can be snapped onto mounting rails Dimensions W x H x D [mm] 45 x 129 x 160 mm Weight 0.3 kg Ambient temperatures Ambient temperatures max.
  • Page 53: Pin Assignment

    Interface modules 3.4 Interface module SB70 3.4.4 Pin assignment Flat connector X1 The cable SC62 is used to connect the interface modules to the SIMATIC TDC / FM458-1DP components (for more information, refer to the SIMATIC TDC / FM458-1DP documentation). Digital inputs, terminal block X2 Table 3- 5 Pin assignment of the digital inputs of interface module SB70, terminal block X2...
  • Page 54: Block Diagram

    Interface modules 3.4 Interface module SB70 3.4.5 Block diagram Figure 3-10 Block diagram of interface module SB70 Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 55: Interface Module Sb71

    Interface modules 3.5 Interface module SB71 Interface module SB71 Article number 6DD1681-0DH1 Description Interface module SB71 is used to adapt 8 digital DC signals of the SIMATIC TDC / FM458-1DP system with electrical isolation to the signal level of the plant side. The cable SC62 is used to connect the interface modules to the SIMATIC TDC / FM458-1DP components (for more information, refer to the SIMATIC TDC / FM458-1DP documentation).
  • Page 56 Interface modules 3.5 Interface module SB71 Green LED The SIMATIC TDC / FM458-1DP-side voltage supply is indicated by a green LED (P). Red LED The SIMATIC TDC / FM458-1DP-side voltage supply (1P, 1M) is short-circuited (fault). Voltage supply on plant side The 24/48 V DC power supply voltage for signals on plant side is wired to terminal block X4: Terminal X4 Voltage on plant side...
  • Page 57: Signals

    Interface modules 3.5 Interface module SB71 3.5.1 Signals Yellow LED The status of each of the eight signals is displayed by a yellow LED (1...8). Terminal block for digital signals Terminal block X2 provides two screw terminals for each signal: •...
  • Page 58 Interface modules 3.5 Interface module SB71 The following figure shows a typical application: Figure 3-11 Application example of an SB71 interface module on digital I/O module SM500 Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 59: Technical Specifications

    Interface modules 3.5 Interface module SB71 3.5.3 Technical specifications General data Mounting system The enclosure is suitable for snap-on mounting to rails Dimensions W x H x D [mm] 45 x 129 x 160 mm Weight 0.3 kg Ambient temperatures Ambient temperatures max.
  • Page 60: Pin Assignment

    Interface modules 3.5 Interface module SB71 3.5.4 Pin assignment Flat connector X1 The cable SC62 is used to connect the interface modules to the SIMATIC TDC / FM458-1DP components (for more information, refer to the SIMATIC TDC / FM458-1DP documentation). Digital outputs, terminal strip X2 Table 3- 6 Pin assignment of the digital outputs of interface module SB71...
  • Page 61: Block Diagram

    Interface modules 3.5 Interface module SB71 3.5.5 Block diagram Figure 3-12 Block diagram of interface module SB71 Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...
  • Page 62: Interface Modules Su12 And Su13

    Interface modules 3.6 Interface modules SU12 and SU13 Interface modules SU12 and SU13 Article number SU12 6DD1681-0AJ1 SU13 6DD1681-0GK0 General SU12 SU13 Interface module SU12 is a Interface module SU13 is a 10-pole terminal block that is used to wire the 50-pole terminal block that is used to wire 50 analog or digital signals of a signals of a 50-pole connector (SIMATIC TDC /...
  • Page 63: Function Description

    Interface modules 3.6 Interface modules SU12 and SU13 3.6.1 Function description Through use of interface modules SU12 and SU13, a 1:1 connection is established from the SIMATIC TDC / FM458-1DP-side ribbon cable connector X1 to the plant-side terminals X2, with the exception of the following terminals. The following signal lines are fused at the terminals (0.5 A slow-blow, internal resistance 0.25 Ω): Interface module...
  • Page 64: Additional Components

    Interface modules 3.6 Interface modules SU12 and SU13 3.6.2 Additional components Cables for: The following cables are required to wire the interface modules to the modules: SU12 Table 3- 8 Modules and signal cables as additional components for SU12 Cable Modules Connectors SC62...
  • Page 65: Pin/Terminal Assignment X1/X2

    Interface modules 3.6 Interface modules SU12 and SU13 3.6.4 Pin/terminal assignment X1/X2 The screw terminal numbers of X2 are identical with the numbering of ribbon cable connector in accordance with the pin counting mode. Conductor cross-sections Interface module Minimum conductor cross- Maximum conductor cross sec- section on terminal block X2 tion on terminal block X2...
  • Page 66: Technical Specifications

    Interface modules 3.6 Interface modules SU12 and SU13 SU13 Figure 3-14 SU13 circuit diagram The components are described in section Function description (Page 63). 3.6.5 Technical specifications General data Dimensions W x H x D [mm] 45 x 129 x 160 mm Weight 0.3 kg Ambient temperatures...
  • Page 67: Index

    Additional components, 64 Application notes, 64 Function description, 63 General, 62 SB10 SU12 Application notes, 31 Technical Data, 66 Description of interface module SB10, 28 SU13 Digital signals, 32 Technical Data, 66 Signals, 30 Technical specifications, 32 SB60 Application notes, 37...
  • Page 68 Index Interface modules (for SIMATIC TDC / FM 458-1DP) Product Information, 04/2024, A5E53479401-AA...

Table of Contents