TABLE OF CONTENTS X1-8 Door Controller Overview ......1 Apply Power ............7 X1 Door Controller Power �����������������������������������������1 Ground the System �����������������������������������������������������7 X1 Door Controller PCB Components ������������������1 Wire AC Power �������������������������������������������������������������7 XD Module PCB Components ��������������������������������2 Wire the Battery ����������������������������������������������������������7 Door Controller Plug-In Terminals ������������������������2 Wire the Modules ��������������������������������������������������������7 Check the Addresses of the Modules ����������������...
X1-8 DOOR CONTROLLER OVERVIEW The X1 Series is a cloud-based door access controller that is fully programmed in Dealer Admin™ and maintained in Virtual Keypad™� This guide will cover mounting the system, wiring devices to the system, configuring network options, applying power, programming the system in Dealer Admin, and testing the system�...
X1 and XD Headers R2 W2 G2 B2 DS RX Door Controller Plug-In Terminals Insert Wiring terminals on an X1 Series system is done easily by using the plug-in terminals� Plug In 1� Insert the wire into the slot� 2� Tighten the screw on the bottom�...
MOUNT THE SYSTEM The metal enclosure for the X1 Series must be mounted directly to a wall, backboard, or other flat surface in a secure, dry place to protect the system from damage� Do not remove the PCBs from the enclosure�...
WIRE THE INPUTS Door Switch (DS) Connect a door contact or door position switch to indicate the status of the door, whether it is open or closed� Use this terminal if enabling door prop or door force� This terminal is a Normally Closed input� Request to Exit (RX) Connect a motion sensing device or a mechanical switch to provide RX capability to the system�...
WIRE THE ELECTRONIC LOCK Form C Relay The X1 Series system provides a Form C (SPDT) relay for controlling locks and other electronically-controlled barriers� The three relay terminals marked NO C NC allow you to connect the device wiring to the relay for module control�...
DETERMINE COMMUNICATION The options in this section are in the DMP-recommended installation order� If an option is not part of your desired application, move to the next option� Ethernet Port Ethernet Connection Connect an Ethernet cable from the LAN/WAN connection to the X1 PCB Ethernet port�...
APPLY POWER Warning: Refer to your local state regulations before connecting to building power� Wiring methods shall be in accordance with NEC, NFPA72, ANSI, and with all Authority Having Jurisdiction Ground the System Be sure to secure the green wire lead Model 505-12 to an earth ground�...
Check the Addresses of the Modules The Module address is based on its location in the enclosure� XD 1 - Address 2 X1 - Pre-Addressed to Address 1 R2 W2 G2 DS RX XD 7 - Address 8 XD 2 - Address 3 R2 W2 G2 DS RX R2 W2 G2...
Door Controller Wiring Example The diagram here shows the transformer and the battery wiring� It also shows a possible application with an electronic lock wired normally closed with wet contacts� To 505-12 Power Supply +AC/DC- +BAT- R2 W2 G2 DS RX Jumper Set to Wet White Green...
Module Wiring Example A module wires similarly to a Door Controller, except the module locks must be wired in a dry state with power supplied by the built-in 505-12 5 Amp Power Supply� Wiring from Previous X1/XD R2 W2 G2 DS RX 12VDC White...
CONNECTION SETTINGS If not connecting over Ethernet, connect to Wi-Fi at this time� If connecting over Ethernet, skip to Configure Network Settings� Configure Wi-Fi Settings On power up, the X1 broadcasts an SSID of DMPX1 followed by the system’s serial number� No password is required to connect to the SSID�...
PROGRAM IN DEALER ADMIN After you’ve installed the X1 Series Door Controller and configured basic communication settings, follow the steps in each of the following sections to program a system in Dealer Admin: 1� Sign In to Dealer Admin 2� Add a Customer 3�...
6� Turn on additional options as needed� 7� Press Save� Add Card Formats The first card format for any door is defaulted to DMP� Refer to Card Format Options below when programming card formats� 1� In Card Formats, press the Add icon �...
Enable Video Services 1� In Video Services, press the Add icon � 2� Select the types of cameras or NVRs that you want to enable on the system� 3� Select any third-party applications that you want to enable on the system� This allows users to sign in to their services from Virtual Keypad�...
TEST THE SYSTEM Make sure that the Reader LED(s) is on and the Door Controller’s Power LED is on� If connected to Wi-Fi, the Wi-Fi LED is on solid� If connected to network, the Network Port light is blinking� For cell and all communication methods, check that Door Controller is communicating with Dealer Admin and Virtual Keypad after Dealer Admin programming is completed�...
3 Year warranty against defects in materials and workmanship� Visit DMP�com for full details� I N T R U S I O N • F I R E • A C C E S S • N E T W O R K S...