C4-DIN-8REL-E 8-Channel Relay
Introduction
The Control4® 8-Channel Relay controls up to eight (8) devices from one (1)
module in the Control4 system. It installs in a panelized backbox using typical
wiring standards and communicates to the Control4 system using a CAT5 Ethernet
connection.
Box Contents
8-Channel Relay
Warranty Card
Specifications and Supported Fixtures
The specifications are described below.
Model Number
Power Requirements
Line Feeds (Circuits)
Power Consumption
Supported Load Types
Control Communcations
Module Max
Line-In 1 Max
Line-In 2 Max
Line-In 3 Max
Line-In 4 Max
Individual Channel Max
Sixteen (16) Line Voltage
Screw Terminals (Line 1, Line
2, Line 3, Line 4, Neutral,
Earth Ground, Loads 1-8, Aux
In, Aux Out, unused)
One (1) Ethernet
8-Channel
Relay
Installation Guide
(this document)
C4-DIN-8REL-E
100-277VAC, 50/60 Hz
4
3W
Incandescent, Halogen, Electronic Low Voltage
Transformers (ELV); Magnetic Low Voltage
Transformers (MLV); Fluorescents; Compact
Fluorescents; LEDs; Motors.
Ethernet
Load Ratings
120V
240V
64A
64A
16A
16A
16A
16A
16A
16A
16A
16A
16A
16A
1HP
2HP
Connectors
One (1) 26AWG to 12AWG (.12mm
per terminal
RJ-45
™
Operational Temperature
Humidity
Storage
H x W x D
DIN Module Width
Weight
Shipping Weight
Warnings and Considerations
WARNING!
the panel before installing or servicing this product. Improper use or
installation can cause SERIOUS INJURY, DEATH or LOSS/DAMAGE OF
PROPERTY.
ATTENTION!
d'alimentation à le panneau avant d'installer ou de réparer ce produit. Une
mauvaise installation ou utilisation peut entraîner des blessures graves,
décès ou perte / dommages à la propriété.
WARNING!
ATTENTION!
WARNING!
panel for adequate grounding. Use the device's ground terminal to make a
secure connection to the safety ground of the electrical system.
ATTENTION!
avec un panneau métallique de mise à la terre adéquate. Utilisez la borne
de terre de l'appareil d'établir une connexion sécurisée à la terre de
sécurité du système électrique.
IMPORTANT!
accordance with all national and local electrical codes.
IMPORTANT!
in a location where the vented cover is not blocked. At least 12 inches
(30cm) clearance is required away from the front of the panel. Some local
codes may require as much as 30 inches clearance.
IMPORTANT!
277V
64A
IMPORTANT!
16A
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See "Troubleshooting."
16A
16A
IMPORTANT!
16A
Control4 could void the user's authority to operate the equipment.
16A
2
2
to 4mm
)
Environmental
32˚ F - 104˚ F
(0˚ C - 40˚ C)
5% - 95%
Non-condensing
-4˚ F - 158˚ F
(-20˚ C - 70˚ C)
Dimensions
8.5" x 4.3" x 2.3" (215 mm x 109 mm x 57 mm)
12M
2.9 lbs. (1.3 kg)
3.3 lbs. (1.49 kg)
Turn OFF electrical power to all circuit breakers feeding into
Coupez l'alimentation électrique à tous les disjoncteurs
This device must be protected by a circuit breaker (20A max).
Cet appareil doit étre protègè par un disjoncteur (20A max.)
DO NOT rely solely upon the device's contact with a metal
NE COMPTEZ PAS uniquement soley au contact de l'appareil
This device must be installed by a licensed electrician in
The panel used with this device is air cooled. Install the panel
Only install this device indoors.
Using this product in a manner other than outlined in this