SMARTWINGS Helix Dial Remote Programming Manual

Hide thumbs Also See for Helix Dial Remote:

Advertisement

Quick Links

Programming & Smart Pairing Guide
Helix Dial Remote
Windproof Shade
INS-102-C078
A-01 March 2025

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Helix Dial Remote and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMARTWINGS Helix Dial Remote

  • Page 1 Programming & Smart Pairing Guide Helix Dial Remote Windproof Shade INS-102-C078 A-01 March 2025...
  • Page 2 After completing the pairing process, please stick one copy of the corresponding QR code in the designated field. Keep a backup to facilitate future maintenance and usage, and store the instruction manual properly. Matter Z-wave Windproof Shade 1 Matter Z-wave Windproof Shade 2 Matter Z-wave...
  • Page 3 Note Important Safety Instructions...
  • Page 4 Motorized Windproof Shades...
  • Page 5: Table Of Contents

    TABLE OF CONTENTS 1. Remote Overview ..........1 2. Motor Interface Cables ........2 3. Helix Dial Remote Programming .......3 .....3 3.1 Pairing Channel & Group Control .........4 3.2 Change Motor Direction ..........5 3.3 Adjust Limits ...........6 3.4 Favorite Position ........7 3.5 Adjust Motor speed ..........8...
  • Page 6: Remote Overview

    Remote Overview FRONT Channel Display STOP/LED CHANNEL Battery Light DOWN Percentage/ Dimming Indicator BACK ON/OFF Type-C Technical specification Function instruction One number of screen means one control channel. Press Input Voltage: 3.7V CHANNEL button to change the channel. On the analogy Transmitting Frequency: of this, loose finger when the screen shows the suitable 433.925MHz...
  • Page 7: Motor Interface Cables

    Motor Interface Cables External Power Supply Port Programming Button Antenna Bundle (DC 24V) on Motor Head (consisting of 3 antennas) * Please do not cut the antenna...
  • Page 8: Helix Dial Remote Programming

    Helix Dial Remote Programming 3.1 Pairing Channel & Group Control The Helix Dial remote features 8 channels, with Channel 0 serving as the default group control channel to operate all shades under its 8 channels simultaneously. To customize a channel for controlling multiple motors, group pairing can be performed by pairing multiple shades to a specific channel.
  • Page 9: Change Motor Direction

    Helix Dial Remote Programming 3.2 Change Motor Direction Verify the motor direction by pressing the UP or DOWN button. If the shade does not function as expected, adjust the motor direction accordingly. Method 1 This method is applicable only during the initial setup before seting limits.
  • Page 10: Adjust Limits

    Helix Dial Remote Programming 3.3 Adjust Limits Hold UP to move the shade Hold UP and STOP together The shade will jog twice to indicate to the desired upper limit for 2 seconds to save the upper limit has been set...
  • Page 11: Favorite Position

    Helix Dial Remote Programming 3.4 Favorite Position The favorite position allows you to set a custom stopping point between the upper and lower limits (one favorite position per shade motor). Press STOP (To Save Position) Press STOP Press UP and CHANNEL...
  • Page 12: Adjust Motor Speed

    Helix Dial Remote Programming 3.5 Adjust Motor speed Note: The motor is set to its highest speed by default from the factory. To Decrease Speed Press DOWN Press DOWN Press UP and CHANNEL Shade will jog once Shade will jog once The motor will jog once or twice.
  • Page 13: Mirror Remotes

    Helix Dial Remote Programming 3.6 Mirror Remotes Follow the steps below to copy settings from an existing remote to a new one. Select channel that operates the shade Note: Select the channel on the existing remote to be copied, and select the channel on the new remote where the existing channel will be copied.
  • Page 14: Reset To Factory Settings

    Helix Dial Remote Programming 3.7 Reset to Factory Settings Press and hold the programming button for 14 seconds until the motor beeps four times in total. Hold the programming button until the motor jogs four times to complete the reset.
  • Page 15: Motor P Button Functions

    Helix Dial Remote Programming 3.8 Motor P Button Functions Entering Matter Pairing Mode Entering Z-Wave Pairing Mode...
  • Page 16: Matter Smart Pairing

    Matter Smart Pairing 4.1 Work With Matter Over Thread...
  • Page 17 Matter Smart Pairing...
  • Page 18: Matter Network Pairing Mode

    Matter Smart Pairing 4.2 Matter Network Pairing Mode Method One: Press and hold the P button on the motor head for 6 seconds until the shade jogs twice, then release the button. The motor will beep twice and jog once, indicating that windproof shade network pairing mode has been activated.
  • Page 19: Z-Wave Smart Pairing

    Z-Wave Smart Pairing 5.1 Z-Wave Technical specifications Technical Specifications Communication Protocol Z-Wave 908.42MHz (US) 868.42MHz (EU) Radio Frequency 921.42MHz (AU) More than 200m outdoors About 70m indoors (depending Wireless Range on building materials) Working current ~25mA Operating Temperature -10°C to + 45°C Operating Humidity Up to 85% non-condensing Z-Wave Specifications...
  • Page 20: Z-Wave Security & Compatibility

    Z-Wave Smart Pairing 5.2 Z-Wave Security & Compatibility This device is a security enabled Z-Wave PlusTM product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. When a node includes into a S2 Z-Wave network, the node supports S2 unauthenticated class, S2 authenticated and so do the supported CCs.
  • Page 21: Commands List

    Z-Wave Smart Pairing Commands List This device requires the following command classes to be supported and recognized by your Z-Wave controller: Command Classes Version Required Security Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 None COMMAND_CLASS_TRANSPORT_SERVICE_V2 None COMMAND_CLASS_SECURITY_2_V1 None COMMAND_CLASS_SUPERVISION_V1 None COMMAND_CLASS_APPLICATION_STATUS_V1 None COMMAND_CLASS_WINDOW_COVERING_V1 Highest granted Security Class COMMAND_CLASS_SWITCH_MULTILEVEL_V4 Highest granted Security Class COMMAND_CLASS_BASIC_V2...
  • Page 22: Z-Wave Network Pairing Mode

    Z-Wave Network Pairing Mode 5.3 Z-Wave Network Pairing Mode Method One: Press UP and CHANNEL (jogs once), then press DOWN (jogs once), and finally press UP and CHANNEL (jogs once) in sequence. The motor will beep thrice and jog once, indicat- ing that windproof shade network pairing mode has been activated.
  • Page 23: Exit Z-Wave Network

    Z-Wave Network Pairing Mode 5.4 Exit Z-Wave Network Press UP and CHANNEL (jogs once), then press DOWN (jogs once), and finally press UP and CHANNEL (jogs once) in sequence. The motor will beep thrice and jog once, indicating that windproof shade has been removed from the network and automatically disconnected from the app.
  • Page 24: Special Rule Of Each Command

    Z-Wave Network Pairing Mode 5.5 Special Rule of Each Command Library Basic Device Class: BASIC_TYPE_ROUTING_SLAVE Generic Device Class: GENERIC_TYPE_SWITCH_MULTILEVEL Specific Device Class: SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL Z-Wave Plus Info Report Command Class Z-Wave Plus Version: 0x02 Role Type: 0x05 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON) Node Type: 0x00 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) Installer Icon Type: 0x1A00 (ICON_TYPE_GENERIC_WINDOW_COVERING_POSITION_ENDPOINT_AWARE) User Icon Type: 0x1A00...
  • Page 25 Z-Wave Network Pairing Mode Association Command Class The Curtain Motor support 1 association group and max 5 nodes. Grouping Identifier Max Nodes Send Commands 1. Switch Multilevel Report. Changings of curtain caused by user action or receiving of Multilevel Set or Basic Set or Window Covering Set will trigger. Group 1 0x05 2.
  • Page 26 Z-Wave Network Pairing Mode Configuration Set Command Class Size Range Description Default Version This parameter can be used to set the motor Set to start open hand start function 0x01 holding hands 0x01 = open 0x00 = close This parameter can be used to set the motor rotation direction.

Table of Contents