GmbH reserves all rights to this documentation. The applicable provisions are stipulated in the "imc Software License Agreement". The software described in this document may only be used in accordance with the provisions of the "imc Software License Agreement". Open Source Software Licenses Some components of imc products use software which is licensed under the GNU General Public License (GPL).
This does not, however, guarantee that a component will not fail after longer operation. Therefore, all imc devices are granted liability for a period of two years. The condition for this guarantee is that no alterations or modifications have been made to the device by the customer.
Page 8
In order to comply with the value limits applicable to Class B devices according to part 15 of the FCC regulations, all signal leads connected to the imc BUSDAQflex devices must be shielded. Unless otherwise indicated, no connection leads may be long leads (< 30 m) as defined by the standard IEC 61326-1.
This certification has the sole purpose of releasing imc from the obligation to have the electrical equipment tested prior to first use (§ 5 Sec. 1, 4 of DGUV Regulation 3). This does not affect guarantee and liability regulations of the civil code.
Page 13
Devices from imc have been carefully designed, assembled and routinely tested in accordance with the safety regulations specified in the included certificate of conformity and has left imc in perfect operating condition. To maintain this condition and to ensure continued danger-free operation, the user should pay particular attention to the remarks and warnings made in this chapter.
1x protective cover for the remote control socket type 0B · Getting started with imc BUSDAQflex (one copy per delivery) Note File a claim about every fault as soon as it is detected. Claims for damages can only be honored within the stated claims period.
1. Observe the data in the manual chapter "Technical Specs", to prevent damage to the unit through inappropriate signal connection. 2. If you are using a internal device drive, observe the notes in the imc software manual. Particular care should be taken to comply with the storage device's max. ambient temperature limitation.
Page 16
This option provides the possibility to use the DSUB-9 as an output and to power connected imc CANSAS modules. If it is used as an input it is possible to supply the BUSDAQ via CAN-cable (e.g. OBD). In this case there...
Page 18
Automatic conclusion of measurement and data saving upon power outage imc BUSDAQflex comes with UPS-functionality to ensure the integrity of data in case of power outages. When power outage occurs, this functionality prevents loss of data and is referred to as Power Fail. If the power fails, the measurement stops automatically and the data are saved to the internal bulk memory ("μ-Disk": flash media...
If no measurement is currently running, it takes only approx. 1 sec. for the device to be deactivated. 3.3.2.6 Remote On/Off The imc BUSDAQflex can be activated and deactivated via the Control switch. When the pin Remote On/Off is connected with -Supply via a push-button switch, the device can be activated/ deactivated as with the blue LED- button.
When using the device with a DC-voltage supply and custom-designed supply cable, be sure to take this into account by providing adequate cable cross-section. 3.3.5 Batteries For an uninterruptable power supply (UPS) Super-Caps are used to supply the imc BUSDAQflex device. imc BUSDAQflex devices delivered by imc after November 2022 will have a "battery label"...
Notes on connecting Chapter 3 3.3.8 Storage media in the device This section describes how to handle the storage media of the imc measurement devices and how to use them with imc STUDIO. The storage media are exclusively for data acquisition with imc STUDIO.
If you complete the process within the specified RAM buffer duration, this is certain to work without any loss of data (see in the imc STUDIO manual "Setup pages - Configuring device" > "Storage options and directory structure" > "RAM buffer time"). Note that not only the time for the swap must be buffered, but that the buffered data must also be transferred to the new disk once the swap has been completed.
Page 24
3.3.8.1.2.1 imc Systems - Adding a device (Add) Even if you have already been connected with the device by means of the imc STUDIO software, it is still not listed in the Explorer. It's possible to measure with one device while copying data from another.
Page 25
Start the explorer and enter "ftp://" and the IP address of the device: Note · In general it is a read only operation. If you intend to delete files via FTP, you have to add "imc@" between "ftp://" and the IP address: Example: ftp://imc@10.0.10.219...
Page 26
Note Recommendation · imc recommends formatting in the device: In comparison to formatting by Windows, this provides higher data writing rates for high-speed channels. · Only one(!) partition may be created. Multiple partitions may cause the measuring device not to recognize the storage medium.
PC aid. · If the PC is connected to the measuring device, imc STUDIO documents the error with an message in the Logbook and switches the LED off. Any one-time data overflow only shows up in the Logbook, since the LED is reset afterwards. If data overflow occurs repeatedly, The LED is activated again, the PC records the message again, and as a result the LED blinks intermittently.
Do not allow liquids to enter the housing interior. 4.3 Storage As a rule, the imc BUSDAQflex devices must be stored in a temperature range of -40°C to +85°C. 4.4 Transport When transporting, always use the original packaging or a appropriate packaging which protects the device against knocks and impacts.
/ license). In order to be able to install or uninstall imc STUDIO products, you must be registered with a user account possessing administrator rights to the PC. This applies to the overwhelming majority of all installations of Windows.
(e.g. via 5 GBit Ethernet) and to connect these groups to NAS-components, for instance, via these lines. When such imc devices are included which use network-based PTP-synchronization (e.g. CRXT or CRFX-2000GP), then it is necessary to use network switches which fully support this protocol on the hardware side. Appropriate network components are also available as imc accessories (e.g.
Page 34
"Setting Up - Connect the device" > "Special options for connecting to the device". Step 3: Integrating a device into an experiment Now you are ready to add the device to the imc STUDIO experiment. If your device is unknown to the system, first perform the "device search". Ribbon View Home >...
— — correction 1 Extend serial number range by four digits (three for imc EOS) 2 Max. aggregate sampling rate (see data sheet) 3 2000 via EtherCAT else 400 4 Number of imc STUDIO Monitor-connections or imc REMOTE (as of 14xxxx) connections...
6.2 imc BUSDAQflex device series imc BUSDAQflex is a series of data loggers for CAN, CAN FD, LIN, ARINC, FlexRay, XCPoE, MVB and EtherCAT. The basic configuration with default configuration with 2 CAN-nodes can be expanded to up to 12 nodes in the larger device models for various fieldbuses and vehicle buses.
6.4 CAN Termination Each imc BUSDAQflex (BUSFX) offers 2 CAN nodes as basic equipment. The imc CANSASflex modules (CANFX), which are connected to the BUSFX device via the click connection, are located at the CAN 1 node of slot 1 (see labeling on the device, CAN 1).
DSUB-15 Chapter 7 7 Pin configuration 7.1 DSUB-15 The Standard imc plug is a 1:1 DSUB-15 to screw terminal adaptor. It is offered in a number of variants. Pin configuration Metal connector ACC/DSUBM- DI2-4 DSUB Terminal DIGITAL IN DIGITAL OUT...
The device can be powered on or off by the control-socket's Remote On/Off pin. Therefore, Remote On/Off (Pin 2) has to be connected with -Supply (Pin 1) using a pushbutton. Be aware that BUSDAQflex-2 behaves differently in this situation than the larger model variants: · BUSFX-2(/S), BUSLOG Switch On/Off by briefly jumpering using a pushbutton.
Page 57
The safe handling of measurement devices requires a good knowledge of the system. At our training center, experienced specialists are here to share their knowledge. E-Mail: schulung@imc-tm.de Internet: https://www.imc-tm.com/service-training/imc-academy International partners You will find the contact person responsible for you in our overview list of imc partners: Internet: https://www.imc-tm.com/imc-worldwide/ imc @ Social Media https://www.facebook.com/imcTestMeasurement https://www.youtube.com/c/imcTestMeasurementGmbH https://x.com/imc_de...