lmportant safety instructions Contents lmportant safety instructions 1. Safety Precautions 1.1 Before Connecting Please keep this manual for future reference. 1.2 In Using This manual contains all the safety installation and operation instructions of the rack type energy storage LiFePO battery.
1.1 Before Connecting 1. Safety Precautions Reminding! Warning!!! (1) It is important and necessary to read the user manual carefully before installing or (1) After unpacking, please check product and packing list first, if product is damaged or using battery. Failure to do so or to follow any of the instructions or warnings in this lack of parts, please contact with the local retailer.
2.3 Function description 2. Basic information 2.1 Product overview ES51.2-400BS is composed of 4 battery modules and a cabinet, as shown below. Rack type energy storage battery is mainly used in the field of household power storage. At the same time, it is also suitable for the internal energy storage of RV, household energy storage and temporary buildings.
2.5 Cabinet details 3. Installation instructions 3.1 Installation Steps Install a battery module to the bottom layer of the battery cabinet, and then continue installation from bottom to top in the same way After the battery module is installed, connect the power cable and communication cable in turn, as shown in the figure below: Cabinet front Caster wheels...
3.2 Installation notes Before installation, please read this manual carefully and familiarize the installation steps. (1) Be sure to leave a certain space around for heat dissipation during installation. (2) Avoid sunlight direct and rainwater infiltration during outdoor installation to cause battery damage.
4. Parallel structure diagram 3.5 Necessary Installation Tools One ES51.2-400BS product Insulated Allen Key Set Multimeter + Current clamp Insulated Screwdriver Set Drill+Hammer from 2 mm to 8 mm Insulated Torque Lifting Strap + RS232/USB +Screw Electrician Scissors Terminal (insulated) Wrench Set Mechanical Lifter Two ES51.2-400BS products...
More than Two ES51.2-400BS products Note: 1. When the battery pack is used in parallel, the BMS automatic coding can encode the host to wake up the slave, and the slave can automatically wake up after the host wakes up. Combiner 2.
6.BMS communication settings 6.1 BMS communication and setting 6.2 Communication Instructions When the load (such as inverter) needs to communicate with the battery, in order to establish normal 6.2.1 CAN Communication communication with the load, BMS needs to set the following settings for each brand. The RS485 CAN communication, baud rate 500K.
6.3 Inverter Compatibility List 6.4 Low Voltage Battery to inverter CAN Terminal Pin Out Battery Protocol Battery Modules Inverter brand Model LOW VOLTAGE INVERTER CAN /BMS Selection Pylon Growatt LV ALL Inverter Terminal Inverter SIDE Battery SIDE RJ45 CAN TERMINAL Pylon SRNE LV ALL...
6.5 Low Voltage Battery to inverter RS485 Terminal Pin Out 7. Technical parameter list LOW VOLTAGE INVERTER RS485 Product number ES51.2-100BS Array Mode Inverter Terminal Inverter SIDE Battery SIDE RJ45 RS485 TERMINAL Nominal Capacity (Ah) Type ( PIN Number )
Warranty Card and Warranty Condition 8. Maintenance and conservation Problem description Item Possible causes Solution Product Information 1. The button is damaged 1. Check whether the button is normal; The battery cannot be turned or the button cable is 2. Check whether the voltage of the battery pack is normal; disconnected;...
So please charge the batteries to 80% every 3-6 months. 3. Performance Warranty (Standard) Eastman warrants and represents that the Product retains at least Cycle life of 6000 Times @80% DOD, 25˚C, 0.2C charge and discharge with 80% DOD. Standard for 5 year warranty with 6000 cycle @80% DOD, 25˚C, 0.2C.
Page 16
EASTMAN NEW ENERGY PRIVATE LIMITED Plot No 264, Sector-7, IMT Manesar, District - Gurugram Haryana-122050, India...
Need help?
Do you have a question about the ES51.2-100BS and is the answer not in the manual?
Questions and answers