Connection set for cosmo 2-line solar station to the cps storage tank with two heat exchangers

Advertisement

Available languages

Available languages

Quick Links

G U T E S K L I M A
B E S S E R L E B E N
M ON TAGE- U N D BET RIEBSA NLE ITUN G
A NS CH LU SSSET FÜR C O S MO 2 -STRA NG SOL ARS TATION
AM C OS M O C P S- SP EIC H ER MIT 2 WÄ RMETAUS CH ERN
INS T RUC T IO NS F O R USE
C O NNE CT I ON SE T FO R CO SM O 2-LINE S OLA R STATIO N
TO TH E C P S STO R AG E TA N K WIT H TWO HEAT EX CH ANG ERS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KBN C2ASM2WTN and is the answer not in the manual?

Questions and answers

Summary of Contents for Cosmo KBN C2ASM2WTN

  • Page 1 G U T E S K L I M A B E S S E R L E B E N M ON TAGE- U N D BET RIEBSA NLE ITUN G A NS CH LU SSSET FÜR C O S MO 2 -STRA NG SOL ARS TATION AM C OS M O C P S- SP EIC H ER MIT 2 WÄ...
  • Page 2: Table Of Contents

    1 I N H A LT S V E R Z E I C H N I S 2 Lieferumfang 2.1 Zu dieser Anleitung 2.2 Produktbeschreibung 3 Technische Zeichnung 4 Vorschriften / Normen / Richtlinien 5 Technische Daten 6 Sicherheitshinweise 7 Montage- und Betriebsanleitung / Installation 8 Inbetriebnahme / Funktionsprüfung / Außerbetriebnahme 9 Wartung...
  • Page 3: Lieferumfang

    2 . 2 P R O D U K T B E S C H R E I B U N G Das Anschlussset ist ein vormontierter Rohrsatz zur Verbindung von COSMO 2-Strang Solarstati- onen am COSMO CPS-Speicher mit 2 Wärmetauschern.
  • Page 4: Technische Zeichnung

    3 T E C H N I S C H E Z E I C H N U N G Maßzeichnung Anschlussset Alle Angaben in mm 4 V O R S C H R I F T E N / N O R M E N / R I C H T L I N I E N Das Anschlussset darf nur in solarthermischen Anlagen zur Verbindung einer C O S M O 2-Strang Solarstation mit einem C O S M O CPS-Speicher mit zwei Wärmetauschern (CPSM2WT...
  • Page 5: Sicherheitshinweise

    A N S C H L U S S S E T F Ü R C O S M O 2 - S T R A N G S O L A R S T A T I O N A M C O S M O C P S - S P E I C H E R M I T 2 W Ä...
  • Page 6: Inbetriebnahme / Funktionsprüfung / Außerbetriebnahme

    8 INBETRIEBNAHME / FUNKTIONSPRÜFUNG / AUSSERBETRIEBNAHME Dämmen Sie den Pufferspeicher, bevor Sie das Anschlussset und die 2-Strang Solarstation montieren. Entnehmen Sie den Rohrsatz aus der Verpackung. Schrauben Sie die kurzen Rohrbögen (1) und (2) mit der kurzen Seite handfest an den Pufferspeicher.
  • Page 7 A N S C H L U S S S E T F Ü R C O S M O 2 - S T R A N G S O L A R S T A T I O N A M C O S M O C P S - S P E I C H E R M I T 2 W Ä...
  • Page 8 ↕“ 19. Bringen Sie den Stellknopf des 3-Wege-Ventil nach links in Position „A 20. Stellen Sie den Stellmotor auf Anschlag links in Position „A“. 21. Stecken Sie den Stellmotor auf das 3-Wege-Ventil und fixieren Sie den Stellmotor mit der beiliegenden Schraube. 22.
  • Page 9: Wartung

    A N S C H L U S S S E T F Ü R C O S M O 2 - S T R A N G S O L A R S T A T I O N A M C O S M O C P S - S P E I C H E R M I T 2 W Ä...
  • Page 10: Pflegehinweise

    1 0 P F L E G E H I N W E I S E Es sind keine Pflegehinweise für dieses Produkt vorhanden.
  • Page 11: Kontaktdaten

    22549 Hamburg Geschäftsführer: Hermann-Josef Lüken Tel: +49 40 80030430 HRB 109633 (Amtsgericht Hamburg) info@cosmo-info.de www.cosmo-info.de 1 2 G A R A N T I E / G E W Ä H R L E I S T U N G / N A C H K A U F G A R A N T I E 1.
  • Page 13 G U T E S K L I M A B E S S E R L E B E N IN S T RUC TIO N S F O R U S E C O NNE CTI ON SET FOR COS M O 2- LIN E SOL AR S TATION TO T HE CP S STOR A GE TA NK WI TH TWO H EAT EXCH A NGERS...
  • Page 14 11 Contact details 12 Guarantee / Warranty / Availability guarantee Item no. 9953331CSM02-mub-ml – Version V01 – Issued 2021/01 Translation of the original instructions We reserve the right to make technical changes without notice! Printed in Germany – Copyright by COSMO GmbH...
  • Page 15: Scope Of Delivery

    C O N N E C T I O N S E T F O R C O S M O 2 - L I N E S O L A R S T A T I O N T O T H E C P S S T O R A G E T A N K W I T H T W O H E A T E X C H A N G E R S ( C P S M 2 W T . . . / C P S H M 2 W T . . . ) 2 S C O P E O F D E L I V E R Y Carefully read these instructions before installation and commissioning.
  • Page 16: Technical Drawing

    3 T E C H N I C A L D R A W I N G Dimensional drawing of the connection set All dimensions in mm 4 R E G U L A T I O N S / S T A N D A R D S / D I R E C T I V E S The connection set may only be used in solar thermal installations to connect a 2-line solar station to a C O S M O CPS storage tank with two heat exchangers (CPSM2WT...
  • Page 17: Safety Instructions

    C O N N E C T I O N S E T F O R C O S M O 2 - L I N E S O L A R S T A T I O N T O T H E C P S S T O R A G E T A N K W I T H T W O H E A T E X C H A N G E R S ( C P S M 2 W T . . . / C P S H M 2 W T . . . ) 6 S A F E T Y I N S T R U C T I O N S The installation and commissioning as well as the connection of electrical components require technical knowledge commensurate with a recognised vocational qualification as a fitter for...
  • Page 18: Commissioning / Function Test / Decommissioning

    8 C O M M I S S I O N I N G / F U N C T I O N T E S T / D E C O M M I S S I O N I N G Insulate the buffer tank before mounting the connection set and the 2-line solar station.
  • Page 19 C O N N E C T I O N S E T F O R C O S M O 2 - L I N E S O L A R S T A T I O N T O T H E C P S S T O R A G E T A N K W I T H T W O H E A T E X C H A N G E R S ( C P S M 2 W T . . . / C P S H M 2 W T . . . ) 10.
  • Page 20 19. Turn the adjusting knob of the 3-way valve to the left to the position „A↕“. 20. Set the actuator to the left limit stop by turning it to the position „A“. 21. Put the actuator onto the 3-way valve and fix the actuator with the enclosed screw. 22.
  • Page 21: Maintenance

    C O N N E C T I O N S E T F O R C O S M O 2 - L I N E S O L A R S T A T I O N T O T H E C P S S T O R A G E T A N K W I T H T W O H E A T E X C H A N G E R S ( C P S M 2 W T . . . / C P S H M 2 W T . . . ) 9 M A I N T E N A N C E 9 .
  • Page 22: Care Instructions

    1 0 C A R E I N S T R U C T I O N S There are no care instructions for this product.
  • Page 23: Contact Details

    22549 Hamburg Managing Director: Hermann-Josef Lüken Phone: +49 40 80030430 HRB 109633 (Local Court Hamburg) info@cosmo-info.de www.cosmo-info.de 1 2 G U A R A N T E E / W A R R A N T Y / AVA I L A B I L I T Y G U A R A N T E E issue January 2021 Subject to technical changes, errors excepted.
  • Page 24 G U T E S K L I M A B E S S E R L E B E N C O S M O GMBH Brandstücken 31 · 22549 Hamburg i n f o @ c o s m o - i n f o . d e w w w .

Table of Contents