Page 3
Content English Start-up guide HAYTECH probes Tango M and Tango XN probes Troubleshooting General information Français Guide de démarrage Sondes HAYTECH Sondes Tango M et Tango XN Dépannage Informations générales...
Page 4
The base station sends the measurement data to quanturi.app. This manual walks you through the installation and setup procedure. After going through all the steps in this manual, the Quanturi monitoring system is ready for use. Usage and precautions...
Page 5
Furthermore, the User undertakes to remove the probes from the material before it is used for any purpose other than conservation. Quanturi may not under any circumstances be held liable for any damages arising from the User's negligent use of the material whether this be directly or indirectly, including –...
Page 6
PRODUCT STICKER number etc. You will receive HAYTECH System 10 MADE IN FINLAND an SMS to confirm your phone Activate your system by QNT100-00 PROBE ID X00001, X000002, X000003, X000004, number.
Page 7
220V ADAPTER looking for network connected internal error connection (refer to page 14) The probes start sending data within 1 hour from the base station start-up. Login to: Temperature https://www.quanturi.app 1321 79°C 1232 74°C 1234 68°C 2223 62°C 1112 55°C for the data visualization.
Page 8
Quanturi.app quanturi.app is the service application for visualizing the Quanturi 79°C 27.6.2018 sensor data and for customizing ALARM 74°C Sensor 5498 73°C 68°C 62°C your account settings. The 12.7.2018 ALARM 55°C Sensor 5487 71°C Temperature 49°C 1321 79°C 1232 74°C 45°C...
Page 9
HAYTECH probes Safety instructions Follow the safety instructions to prevent harm or injury to yourself and people near you when using the Quanturi monitoring System. Store at room For professional temperature use only Sharp spike, please Do not store the...
Page 10
200 m 200 m 200 m NETWORK 220V ADAPTER Install the repeater within or near the hay storage, for example hanging on the wall Temperature 1321 79°C 1232 74°C 1234 68°C 2223 62°C 1112 55°C 2333 49°C of the shed.
Page 11
55°C Sensor 5487 71°C 49°C together with the location of 45°C 38 °C 38°C the hay bale on a table. You can 35°C also use Quanturi service plan to Temperature 1321 79°C 1232 74°C register the probe locations. 1234 68°C 2223 62°C...
Page 12
Tango M and Tango XN probes Safety instructions Follow the safety instructions to prevent harm or injury to yourself and people near you when using the Quanturi System. For professional Do not open any of use only the products Do not store the...
Page 13
Please refer to your with QNT-306 base station and Quanturi.app to If the light of the repeater stays ensure your system circulating, it means it is too far is operational. away from the base station. Move it closer to the base station.
Page 14
Unplug and reconnect the device to reboot it. Wait for the base station to initialize and connect to the network. If the problem persists, contact: support@quanturi.com If the light of the base station enters the circulating blue state: Circulating blue light means that the device is trying to connect to the server.
Page 15
A) If you receive some data, it means that your base station is too far away from the other probes in the storage. B) If you don't receive any data, contact support@quanturi.com If you have a repeater, place some of the probes closer to the repeater and wait for 2-3h.
Page 16
General information Repair and Maintenance Quanturi products are designed so that they do not need any maintenance operations during normal use. If you still find something that requires our attention or your product(s) need(s) repair, please contact Quanturi support for further information.
Page 17
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna.
Page 18
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must be at least 20 cm from the user and much not be co-located or operating in conjunction with any other antenna or transmitter.
Need help?
Do you have a question about the HAYTECH and is the answer not in the manual?
Questions and answers