Altitude
2.2.2.
Operating
2.2.3.
Suspended Particulate
Operating
Vibration
2.2.4.
Operating
Non-operating
Shock
2.2.5.
Operating
Non-operating
Acoustic Noise
2.2.6.
The ambient noise level is no greater than 25 dB (A). The sound-meter on (A) scale is located 1m in front of the
center of the drive front panel. (A): A curve weight
Streaming Write/Read
Insert/Eject
EMC
2.2.7.
EMI/EMS
Radiated
Emissions/Conducted
noise Emissions
EMS
ESD
(Front Panel Only,
integrated product)
Orientation
2.2.8.
The SDX-250V can be installed in three different mounting positions as shown in the figure below. Each position has
a maximum tolerance of ±10 degrees.
SONY AIT-E Turbo drive SDX-250V series Ver.1.0
0 to 10,000 feet
Less than 150 microgram/m
Based Sampling period 24 hours
Swept Sine 5 to 500Hz, @0.25G Peak 1 Octave/min.
3 axis, 3 directions
Swept Sine 5 to 500Hz, @ 0.5G Peak 1 Octave/min.
3 axis, 3 directions
No Data Loss
Half Sine
Performance
5 G Peak 3 ms
3 axes, 3 directions
*Interval 10 seconds
No Device Damage
Half Sine
90 G Peak 3 ms
(30 G Peak 11 ms)
3 axes, 3 directions
* Interval 10 seconds
35dB(A)
60dB(A)
EN 55022 (1998) class B
EN 55024 (1998) A1 (2001) +A2 (2003) class B
Discharge Voltage
Less than 15kV: No operation failure
Less than 20kV: No drive damage
3
2.Specification