Every effort has been made to supply information within this manual which is correct. Wallgate Limited will not be liable for any damage or loss that arises if the person installing, operating or maintaining the unit has not read or not complied with the manual In any event, and without prejudice to any warranties in Wallgate Limited’s terms and...
Product Manual WHB-200 and WHB-200-IR 2. Conventions Certain conventions are used in this manual to make it easier to read and understand. They are given in the sections below. 2.1 Warning A warning with white text on a red background is used to give information about hazards that can cause injury or death.
A piezo electric touch button converts the force applied button to the face of the touch button into an electrical signal. Piezo electric touch buttons are used in the WHB-200 to operate the hot and cold-water taps. IR Sensor The infrared (IR) sensor detects infrared radiation from your hand, this creates an electrical signal.
Product Manual WHB-200 and WHB-200-IR 4. Overview The WHB-200 is a moulded washbasin with hot and cold-water taps that are operated by piezo electric touch buttons. The WHB-200-IR is a moulded washbasin with hot and cold-water taps that are operated by infrared sensors.
See Table 1 on page 17 for the weight. Refer to Figure 2 on page 10 for a typical installation of the WHB-200-PB or WHB-200-IR. • Hot and cold-water supplies are necessary. See Table 1 on page 17 for the specifications of the water supplies.
Product Manual WHB-200 and WHB-200-IR 5.3 Preparing the Washbasin The washbasin must be prepared before attaching it to the wall. To prepare the washbasin refer to figure 4 & follow the instructions below: 1. Remove the protective paper covers from the two push fit connectors on the water inlets of the basin.
Page 13
Product Manual WHB-200 and WHB-200-IR Figure 4 Components of WHB-200-PB or WHB-200-IR Revision 7...
Product Manual WHB-200 and WHB-200-IR 5.4 Mounting the Washbasin WARNING! To maintain the anti-ligature & anti-vandal properties of this product it must be installed in line with the following points. 1. Ensure product fixings are correctly fitted as detailed in the following instructions.
NOTE: Fit a service isolating tap on the water supply feed to each water solenoid valve. This allows for ease of maintenance when required. The isolating tap is not supplied by Wallgate, and should be purchased separately. NOTE: Use of any pipe sealing compound should be avoided to prevent blockages &...
3. If a thermostatic mixer valve (TMV3) (Not supplied by Wallgate Ltd) is fitted to the plumbing system for the basin hot outlet, you may have to adjust the valve to set the correct hot water temperature.
Any service or repair work must be done by a qualified engineer. During the warranty period, the service or repair must only be done by a Wallgate engineer or appointed service agent. Refer to the Wallgate terms and conditions for warranty information.
Product Manual WHB-200 and WHB-200-IR 2. Operate the cold and hot water nozzles by pressing the piezo touch buttons, or if IR sensors are fitted, by bringing your hand to within 50 mm of the IR sensors. The piezo touch buttons and IR sensors do not have any moving parts and are operated by either lightly pressing them with your finger tip or by bringing your hand to within 50mm of the IR sensors.
Product Manual WHB-200 and WHB-200-IR 7. Related Documentation The WHB-200-PB and WHB-200-IR can be used with any of the following control units: • WDC100. For more information on this control unit, refer to the WDC100 product manual. • WDC200. For more information on this control unit, refer to the WDC200 product manual.
Need help?
Do you have a question about the WHB-200 and is the answer not in the manual?
Questions and answers