Addressable Annunciator AW- D117&
Expansion Board AW-D118
AW- D117Addressable Annunciator
&AW-D118 Expansion Board
Use Manual​
Version: 1.0
Date: Nov 11
, 2024
th
ASENWARE LTD
Zhongshan Guta Fire Equipment Technology CO.,Ltd
WEBSITE: www.asenware.com
EMAIL:
info@asenware.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the AW- D117 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ASENWARE AW- D117

  • Page 1 Addressable Annunciator AW- D117& Expansion Board AW-D118 AW- D117Addressable Annunciator &AW-D118 Expansion Board Use Manual​ Version: 1.0 Date: Nov 11 , 2024 ASENWARE LTD Zhongshan Guta Fire Equipment Technology CO.,Ltd WEBSITE: www.asenware.com EMAIL: info@asenware.com...
  • Page 2: Product Specification

    Addressable Annunciator AW- D117 & Expansion Board AW-D118 Product Specification AW-D117 is Addressable Annuciator that can monitor and display fire/fault status of addressable devices or Zones and can remotely control fire alarm panel such as silence an reset. It is designed to cooperate with AW-FP series addressable fire alarm panel.
  • Page 3: Electrical Parameters

    Addressable Annunciator AW- D117 & Expansion Board AW-D118 3、Point According to the device point display mode: one light represents a device of the fire alarm at one address (when using FP128, only one Addressable Annunciator Main Board plus one Addressable Annunciator zone board is needed. When using FP200,...
  • Page 4: Mounting Diagram

    Addressable Annunciator AW- D117& Expansion Board AW-D118 1.5 Mounting Diagram 1. AW-D117 2. AW-D118 ASENWARE LTD Zhongshan Guta Fire Equipment Technology CO.,Ltd WEBSITE: www.asenware.com EMAIL: info@asenware.com...
  • Page 5: Technical Specification

    Addressable Annunciator AW- D117 & Expansion Board AW-D118 2 Technical specification 1. Addressable Fire Alarm Control Panel AW-FP200/AW-FP128 and the Addressable Annunciator communication mode wiring diagram is as following: 2. Panel and AW-D117 main board communication connection wiring diagram Note: The 120R resister needs to be connected to both ends of the CAN bus 3.
  • Page 6: Function Description

    Addressable Annunciator AW- D117 & Expansion Board AW-D118 4. POWER wiring diagram Please connect the DC power supply 14V-28V, and note that the positive and negative poles cannot be reversed 3 Function Description 3.1​ Communication mode setting Communication mode Display mode...
  • Page 7 Addressable Annunciator AW- D117 & Expansion Board AW-D118 As shown in Table 1 (setting the number of connected zone boards for AW-D117 or the coding address of AW-D118). The address dip switch on the Addressable Annuciator (AW-D117) represents the number of connected zone boards.