Advertisement

Available languages

Available languages

Quick Links

USA office: Fontana
AUS office: Truganina
GBR office: FDS Corporation Limited,Unit 4, Blackacre Road, Great Blakenham,Ipswich, Ip6 0FL,United Kingdom
If you're having difficulty, our friendly
customer team is always here to help.
FRA office: Saint Vigor d'Ymonville
THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION.
USA:cs.us@costway.com
AUS:cs.au@costway.com
PLEASE READ AND KEEP FOR FUTURE REFERENCE.
GBR:cs.uk@costway.com
FRA:cs.f r @costway.com
Portable Air Conditioner
Climatiseur Portable
FP10576US-WH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FP10576US-WH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Costway FP10576US-WH

  • Page 1 GBR office: FDS Corporation Limited,Unit 4, Blackacre Road, Great Blakenham,Ipswich, Ip6 0FL,United Kingdom THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. USA:cs.us@costway.com If you're having difficulty, our friendly AUS:cs.au@costway.com PLEASE READ AND KEEP FOR FUTURE REFERENCE. customer team is always here to help. GBR:cs.uk@costway.com FRA:cs.f r @costway.com...
  • Page 2: Before You Start

    Before You Start Please read all instructions carefully. Retain instructions for future reference. Separate and count all parts and hardware. Read through each step carefully and follow the proper order. We recommend that, where possible, all items are assembled near to the area in which they will be placed in use, to avoid moving the product unnecessarily once assembled.
  • Page 3: Electrical Specifications

    Introduction 8. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard. Thank you for choosing this mobile air conditioner to provide you and 9.
  • Page 4: Identification Of Parts

    6.If any hot work is to be conducted on the refrigerating equipment or sealing materials have not degraded to the point that they no longer any associated parts, appropriate fire extinguishing equipment shall serve the purpose of preventing the ingress of flammable be available to hand.
  • Page 5: Control Panel Operation

    2. Selection operating mode The figures in this manual are based on the external view of a standard model. Consequently, the shape may differ from that of the Press the " " button to select a desired mode shown below: air conditioner you have selected.
  • Page 6: Remote Controller

    Notice: ● operation Each mode working principle 1. The operation is effective when the unit is under mode. mode: 2. Press the button in mode,then the unit will work under sleep mode and the up centrifugal fan will turn to low speed automatically. 1.
  • Page 7 signal receptor BUTTON How to Use Used to set automatic off and automatic on time. To operate the air conditioner, aim the remote controller at the SWING signal receptor. The remote controller will operate the air Press this button to automatically swing left and right. conditioner at a distance of up to 5m ( 16.4 feet ) when SLEEP...
  • Page 8: Appliance Maintenance

    Drain Water Never sprinkle water onto the main unit Special reminder: there is condensing water recycling hidden within this unit. The condensing water is partly kept recycled between the condenser and the water plate. When the water level rises to the upper level, the float switch and water full indicator (E4) lights on to remind draining water.
  • Page 9: Troubleshooting

    Maintenance after using Runs but not cooling ● If the door or window is opened 1.If the appliance will not be used for a long time, be sure to Pull out ● If there is another appliance the primary and the secondary rubber plugs of the drain port, in order heat-working like heater or lamp, etc.
  • Page 10: Installation Accessories

    Before claiming repair, check the machine as follows: LED displays Room temperature Replace the room failure code “E0” sensor fails or temperature sensor. Trouble Analysis Analysis damaged. Machine fails to Power supply failure: 1.Plug in; start up. 1.Not plugged; 2.Replace the power LED displays Water-full warning.
  • Page 11: Using Information

    Install Exhaust Hose and Adapter Using Information How to connect the connectors to the Air exhaust duct 1. Extend the air exhaust duct by drawing out the two ends of the duct. Cautions ● Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference.
  • Page 12 Climatiseur Portable...
  • Page 13: Spécifications Électriques

    Introduction 7. Les enfants ne doivent pas jouer avec l'appareil. Le nettoyage et l'entretien ne doivent pas être effectués par des enfants sans surveillance. 8. Si le cordon d'alimentation est endommagé, il doit être remplacé par le Nous vous remercions d'avoir choisi ce climatiseur mobile pour vous fabricant, son agent de service ou des personnes de qualification similaire apporter, à...
  • Page 14: Identification Des Pièces

    6. En cas de travaux à chaud sur l'équipement frigorifique ou les pièces manière sûre. S'assurer que les joints ou les matériaux d'étanchéité ne sont associées, il convient de disposer d'un équipement d'extinction d'incendie pas dégradés au point de ne plus pouvoir empêcher la pénétration approprié.
  • Page 15: Panneau De Commande

    2.Sélection du mode de fonctionnement Les figures de ce manuel sont basées sur la vue extérieure d'un modèle standard. Par conséquent, la forme peut différer de celle du Appuyez sur le bouton " " pour sélectionner le mode souhaité, climatiseur que vous avez choisi. comme indiqué...
  • Page 16 Remarque: ● opération Principe de fonctionnement de chaque mode 1 L'opération est effective lorsque l'appareil est en mode mode: 2 Appuyer sur le bouton en mode , l'unité fonctionnera en mode veille et le ventilateur centrifuge se mettra automatiquement en basse 1.
  • Page 17: Insertion Des Piles

    Récepteur singal BOUTON Comment utiliser le climatiseur Permet de régler l'heure d'arrêt automatique et l'heure de mise en marche automatique. Pour faire fonctionner le climatiseur, dirigez la BALANCEMENT télécommande vers le récepteur de signaux. La Appuyez sur ce bouton pour vous balancer automatiquement de gauche à télécommande fera fonctionner droite.
  • Page 18: Entretien

    Drainage de l'Eau Ne jamais asperger d'eau l'unité principale Remarque spéciale: cet appareil contient un système de recyclage de l'eau de condensation. L'eau de condensation est partiellement recyclée entre le condenseur et la plaque à eau. Lorsque le niveau d'eau atteint le niveau supérieur, l'interrupteur à...
  • Page 19: Dépannage

    Entretien après utilisation Fonctionne mais ne • Si la porte ou la fenêtre est ouverte 1. Si l'appareil n'est pas utilisé pendant une longue période, veillez à refroidit pas • S'il y a un autre appareil fonctionnant retirer les bouchons en caoutchouc primaire et secondaire de l'orifice à...
  • Page 20 Avant de demander une réparation, vérifiez l'appareil comme suit : La LED affiche le Le capteur de Remplacez le capteur code de défaillance température ambiante de température Défaillances Causes Solutions "E0" est défectueux ou ambiante. endommagé. La machine ne Défaillance de 1.
  • Page 21 Installation du tuyau d'évacuation et de l'adaptateur Informations sur l'utilisation Comment raccorder les connecteurs au conduit d'évacuation d'air ? 1. Déployez le conduit d'évacuation d'air en tirant sur les deux Précautions extrémités du conduit. • Gardez l'appareil à une distance d'au moins 1 mètre d'un téléviseur ou d'une radio pour éviter les interférences électromagnétiques.
  • Page 22 Return / Damage Claim Instructions DO NOT discard the box / original packaging. In case a return is required, the item must be returned in original box. Without this your return will not be accepted. Take a photo of the box markings. A photo of the markings (text) on the side of the box is required in case a part is needed for replacement.

Table of Contents