7000PH Allergy Bagged Congratulations on the purchase of your new Sauber Allergy bagged vacuum cleaner. There are many useful features built into your cleaner and we recommend that you carefully read this instruction manual so that you may take best advantage of them.
Before You Begin This cleaner must be operated in accordance with these instructions and used only for domestic household cleaning. This cleaner is not fit to be used as an industrial cleaner and will void the manufacturer’s warranty if used inappropriately. Please read the manual before operating cleaner This will ensure you obtain full benefit from your new cleaner.
Safety Precautions & Warnings IMPORTANT! Always switch off the wall outlet, cleaner and remove the plug from the electricity power supply before cleaning your appliance, when not in use or attempting any maintenance task. The cleaner must only be connected to an AC power supply at the voltage shown on the rating label.
Page 6
ashes, cigarettes, matches, explosive materials 26. Never attempt to make any modifications or anything burning) or use in areas where such electrically to the vacuum cleaner. substances and items may be present. 27. Always store the appliance indoors in a cool and 14.
Page 7
Assembly IMPORTANT! Always switch off the wall outlet, cleaner and remove the plug from the electricity power supply before fitting or removing accessories! LIVE PARTS within the hose, rod and power head. 1. Flexible Hose Fitting: Insert the flexible hose into the hose inlet of the vacuum. Press until it clicks into position.
Accessories Power head Power head Height Adjustment Button Deeply cleans carpets by effectively lifting and removing deeply embedded dust and dirt. The height of the power head can be adjusted to be used on different types of carpet. Note: not recommended for use on hard floors. WARNING! Seek advice from carpet manufacturers before using the motorised power head on woollen or delicate carpets.
Upholstery Tool For vacuuming furniture and upholstery. Mini Hand Turbo Tool Ideal for removing per hair from upholstery and furniture. This accessory features a transparent case so that you can easily see and remove any blockages that may occur. Safety Precautions: Keep hair, hands and feet away from the rotating brush while the turbo brush is running.
Page 10
Instructions for Use Using the Suction Control Dial The suction power can be regulated by using the Suction Control Dial to achieve optimum cleaning results. To change the suction power to suit a particular cleaning task, simply turn the dial to point at the appropriate symbol.
IMPORTANT! Always switch off the wall outlet, cleaner and remove the plug from the electricity power supply before fitting or removing accessories. Turning On/Off the Cleaner Unwind a sufficient length of cable. The yellow mark on the power cable shows the ideal cable length. DO NOT extend the cable beyond the red mark.
Maintenance IMPORTANT! Always switch off the wall outlet, cleaner and remove the plug from the electricity power supply before fitting or removing accessories! LIVE PARTS within the hose, rod and power head. Vacuum Cleaner Storage When not in use, ensure that the cleaner is disconnected from the power supply and that the cable is fully retracted.
Page 13
Remove the dust bag when it is full and replace with a new dust bag. Reinsert the bracket and dust bag assembly. Gently close the Dust Bag Cover, ensuring it clicks into place. Cleaning and Replacing the Pre-Motor Filter IMPORTANT! Always switch off the wall outlet, cleaner and remove the plug from the electricity power supply before performing any maintenance.
Page 14
Maintenance (continued) IMPORTANT! Always switch off the wall outlet, cleaner and remove the plug from the electricity power supply before fitting or removing accessories! LIVE PARTS within the hose, rod and power head. Cleaning and Replacing the Rear Motor HEPA and Carbon Filter The Rear Motor HEPA and Carbon Filter is installed behind the exhaust grille.
Page 15
Cleaning the Mini Hand Turbo Brush WARNING! Ensure the Mini Hand Turbo Brush is disconnected from the cleaner when performing any maintenance. To remove the clear cover the collar lock must be in unlocked by twisting the collar lock anticlockwise. The rotating bristles must be unlocked and in the upward position.
Page 16
Maintenance (continued) Replacing the Power Head Drive Belt & Agitator Bar WARNING! Always switch off the wall outlet, cleaner and remove the plug from the electricity power supply before before performing any cleaning, maintenance or troubleshooting checks. Failure to do so may result in electric shock or personal injury LIVE PARTS within the hose, rod and power head and rod contain electrical connections.
Page 17
Depending on frequency of use, the motorised power head drive belt will occasionally require changing. Disconnect the power head from the telescopic tube. Turn the power head upside down and turn the three locking rods anti-clockwise to unlock the bottom plate. Firstly lift the side of the rotating brush without the belt attached.
Troubleshooting Problems and Solutions Please contact Godfreys Commercial Customer Support on 131 929 to find your local spare parts provider. Fault Solutions The cleaner will not turn on. Check that the power cable is inserted securely; remove from the power supply and then reinsert into the power supply.
Spare Parts Description Product Code Filter Set (Pre-motor & Rear Motor Filters) 32200931 Dust Bag Bracket Assembly 33151857 Dust Bags (5 Pack) 32420366 Hose 31220490 Power Head 11400129 Agitator Bar 33701796...
Page 20
If Godfreys Commercial decide to repair or replace when the product is used in accordance with the terms and your Sauber Allergy, it will do so at its own cost. Any conditions of this warranty statement. transportation costs involved in a claim under this warranty shall be borne by the claimant.
Need help?
Do you have a question about the ALLERGY and is the answer not in the manual?