Nibe ClimateMaster Tranquility SK 024-060 Series Installation, Operation & Maintenance Manual
Nibe ClimateMaster Tranquility SK 024-060 Series Installation, Operation & Maintenance Manual

Nibe ClimateMaster Tranquility SK 024-060 Series Installation, Operation & Maintenance Manual

Advertisement

Quick Links

RESIDENTIAL
TranquiliTy® (SK) PrEMiEr CaSED COil
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
Part#: 97B0177N01 | Created: March 13, 2025
Models: SK 024-060
60Hz – R-454B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ClimateMaster Tranquility SK 024-060 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe ClimateMaster Tranquility SK 024-060 Series

  • Page 1 RESIDENTIAL TranquiliTy® (SK) PrEMiEr CaSED COil INSTALLATION, OPERATION & MAINTENANCE MANUAL Part#: 97B0177N01 | Created: March 13, 2025 Models: SK 024-060 60Hz – R-454B...
  • Page 2: Table Of Contents

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Table of Contents 024-060 Model Nomenclature Tranquility SK Dimensional Data Attentions, Cautions, and Warnings Installation General Information Warranty (U.S. and Canada) Minimum Installation Area Warranty (International) Refrigerant System Servicing Revision History Physical Data and Specifications ClimateMaster works continually to improve its products.
  • Page 3: Model Nomenclature

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Model Nomenclature 024-060 PRODUCT NAME STANDARD S = R-454B Refrigerant S = Standard MODEL TYPE BLOWER MOTOR K = Tranquility (SK) Premier Cased Coil 0 = None FUTURE FUTURE N = Not Applicable N = Not Applicable SIZE...
  • Page 4: Attentions, Cautions, And Warnings

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Attentions, Cautions, and Warnings 024-060 SAFETY WARNING All refrigerant discharged from this unit must be recovered WITHOUT Warnings, cautions, and notices appear EXCEPTION. Technicians must follow industry accepted guidelines and throughout this manual.
  • Page 5 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Attentions, Cautions, and Warnings 024-060 WARNING CAUTION PROPOSITION 65: This appliance contains fiberglass insulation. CUT HAZARD - Failure to follow this caution may result in personal Respirable particles of fiberglass are known to the State of California to injury.
  • Page 6: General Information

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: General Information 024-060 INSPECTION PRE-INSTALLATION Upon receipt of the equipment, carefully check the Installation, Operation, and Maintenance instructions shipment against the bill of lading. Make sure all units are provided with each unit. Horizontal equipment have been received.
  • Page 7 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: General Information 024-060 Work Procedure Checks to the Refrigeration Equipment Work shall be undertaken under a controlled procedure The following checks shall be applied to installations so as to minimize the risk of a flammable gas or vapor using FLAMMABLE REFRIGERANTS: being present while the work is being performed.
  • Page 8 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: General Information 024-060 REPAIR TO INTRINSICALLY SAFE COMPONENTS CASED COIL DESCRIPTION ClimateMaster Tranquility Cased Coils are designed Intrinsically safe components must be replaced. for use with ClimateMaster indoor/outdoor split units and are available for vertical upflow or downflow, CABLING and horizontal left or horizontal right airflow.
  • Page 9: Minimum Installation Area

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Minimum Installation Area 024-060 MINIMUM INSTALLATION AREA Minimum installation area for units that do not have a blower (e.g. w-w) where you do not need mechanical/natural ventilation. Minimum Installation Minimum area where the unit is installed Charge Area ft...
  • Page 10 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Minimum Installation Area 024-060 When the openings for connected rooms or natural ventilation are required, the following conditions shall be applied: The area of any openings above 11.8 inches (300 mm) from the floor shall not be considered in determining compliance with Anv At least 50% of the required opening area Anv shall be below 7.8 inches (200 mm) from the floor.
  • Page 11: Refrigerant System Servicing

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Refrigerant System Servicing 024-060 REFRIGERANT SYSTEM Charging Procedures Verify that air- and water-flow rates are at proper levels before servicing the refrigerant circuit. To maintain In addition to conventional charging procedures, the sealed-circuit integrity, do not install service gauges following requirements shall be followed: unless unit operation appears abnormal.
  • Page 12 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Refrigerant System Servicing 024-060 Leak-detection equipment shall be set at a Before attempting the procedure, ensure that: percentage of the lower flammability limit of the Mechanical-handling equipment is available, refrigerant and shall be calibrated to the refrigerant if required, for handling refrigerant cylinders.
  • Page 13 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Refrigerant System Servicing 024-060 RECOVERY When removing refrigerant from a system, either for In addition, a set of calibrated weighing scales servicing or decommissioning, it is recommended shall be available and in good working order. good practice that all refrigerants are removed safely.
  • Page 14: Physical Data And Specifications

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Physical Data and Specifications 024-060 Tranquility SK Physical Data Model Size Refrigerant Circuit Liquid I.D. (in.) Suction I.D. (in.) Refrigerant Leak Detection System Number of Sensors Cased Coil Dimensions A - Width - in.
  • Page 15: Tranquility Sk Dimensional Data

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Tranquility SK Dimensional Data 024-060 Model Size Refrigerant Circuit Liquid I.D. (in.) Suction I.D. (in.) Refrigerant Leak Detection System Number of Sensors Cased Coil Dimensions A - Width - in. 17 1/2 24 1/2 B - Coil Height (in.)
  • Page 16: Installation

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Installation 024-060 APPLICATIONS The Tranquility SK Premier Cased Coil is designed for upflow, horizontal, and downflow applications. The Tranquility SK Cased coils can be applied in upflow, coils have a dry nitrogen holding charge and are downflow, horizontal-right, and horizontal-left equipped with brazing-stub refrigerant connections applications without modifications.
  • Page 17 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Installation Actual area is 3.5313” w x 8.875”h 024-060 Guides indicate .125” bleed all around Table 2: Coil Applications Figure 3: Installation of a Coil Matched with a Furnace a Size Smaller Furnace Width inch [cm] Coil Down ow or Horizontal-right...
  • Page 18 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Actual area is 3.5313” w x 8.875”h Installation 024-060 Guides indicate .125” bleed all around ClimateMaster split units are shipped with a filter Figure 4: SJ Brazing Instructions drier loose inside the cabinet that must be installed Fully Insulated Suction Line in the liquid line at the line set.
  • Page 19 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Installation Actual area is 3.5313” w x 8.875”h 024-060 Guides indicate .125” bleed all around Figure 7: Air Coil Connection Air Coil To obtain maximum performance of a newly manufactured air coil it should be cleaned before Equalizer Line TXV with Internal...
  • Page 20 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Installation 024-060 Actual area is 3.5313” w x 8.875”h Do not reduce drain-line size less than connection DO NOT OPERATE THE UNIT WITHOUT CONDENSATE- Guides indicate .125” bleed all around size provided on condensate drain pan.
  • Page 21 TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Installation 024-060 Charging the System Actual area is 3.5313” w x 8.875”h WARNING See Compressor Section IOM for charging information. These instructions are intended as an aid to qualified licensed service Guides indicate .125”...
  • Page 22: Warranty (U.s. And Canada)

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Warranty (U.S. and Canada) 024-060 PA G E : 2 2 P a r t # : 9 7 B 0 1 7 7 n 0 1 | C r e a t e d : M a r c h 1 3 , 2 0 2 5 w w w.
  • Page 23: Warranty (International)

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Warranty (International) 024-060 w w w. c l i m a t e m a s t e r. c o m P a r t # : 9 7 B 0 1 7 7 n 0 1 | C r e a t e d : M a r c h 1 3 , 2 0 2 5 PA G E : 2 3...
  • Page 24: Revision History

    TranquiliTy® 30 (SK) aluMinuM TuBE CaSED-COil air HanDlEr – iOM Models: Revision History 024-060 Date Section Description 3/13/25 Created 7300 SW 44 St | Oklahoma City, OK 73179 *97B0177N01* Phone: 800.299.9747 www.climatemaster.com ClimateMaster works continually to improve its products. As a result, the design and specifications of each product at the time of order may be changed without notice and may not be as described herein.

Table of Contents