ML Accessories EX1THWH Installation & Maintenance Manual

Advertisement

INSTALLATION & MAINTENANCE MANUAL
EX1THWH

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EX1THWH and is the answer not in the manual?

Questions and answers

Summary of Contents for ML Accessories EX1THWH

  • Page 1 INSTALLATION & MAINTENANCE MANUAL EX1THWH...
  • Page 2: General Instructions

    These instructions should be read carefully and retained after installation by the end user for future reference and maintenance. These instructions should be used to aid installation of the following products: EX1THWH SAFETY • This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations.
  • Page 3: Installation

    SAFETY This product must be installed in accordance with the latest edition of the IEE Wiring Regulations • (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician • Please isolate mains prior to installation or maintenance •...
  • Page 4 Fig. 2 Fig. 2 If required, carefully remove the cable knock-out on the rear of the baseplate and guide the • If required, carefully remove the cable knock-out on the rear of the baseplate and guide the mains cable mains cable through. Alternatively, the cable can be surface mounted via the cut-out on through.
  • Page 5 Fig. 2 If required, carefully remove the cable knock-out on the rear of the baseplate and guide the mains cable Adjust the overrun timer with the aid of a small screwdriver, turn anti-clockwise to reduce • through. Alternatively, the cable can be surface mounted via the cut-out on the bottom of the product. If (to a minimum of 2 minutes) and clockwise to increase (to a maximum of 30 minutes) (see surface mounted, the cable must be secured under the cable clamp provided Ensuring correct polarity is observed, wire as shown in Fig.
  • Page 6: Dip Switch Settings

    DIP SWITCH SETTINGS DIP SWITCH SETTINGS nterval function Interval function Interval function With the interval function on, the fan operates irrespective of With the interval function on, the fan operates irrespective o With the interval function on, the fan operates irres humidity.
  • Page 7: Humidity Function

    Humidity function Humidity function The humidistat causes the fan to operate when the humidity level reaches the set level (+1 The humidistat causes the fan to operate when the humidity level reaches the set le Humidity function Humidity function Humidity function Humidity function Humidity function Humidity function...
  • Page 8 Factory settings Interval function Interval time 4 hours Humidistat 60% RH Timer 1 min. Start-up timer function • Check all electrical connections are secure with all exposed copper within the terminal and • Check all electrical connections are secure with all exposed copper within the terminal and no loose no loose strands of cable strands of cable •...
  • Page 9: Warranty

    ML Accessories does not accept responsibility for any installation costs associated with the replacement product. Your statutory rights are not affected. ML...
  • Page 10 SUPPLIED BY: (UK) MANUFACTURER ML ACCESSORIES LTD, UNIT E CHILTERN PARK, BOSCOMBE ROAD, DUNSTABLE LU5 4LT, WWW.MLACCESSORIES.CO.UK (EU) AUTHORISED REPRESENTATIVE SLV LIGHTING GROUP, DAIMLERSTRASSE 21-23, 52531 ÜBACH-PALENBERG, GERMANY EMAIL: EPREL@GROUP.SLV.COM MADE IN CHINA 230V IP45 50Hz JBJUNE24_V1...