Airssential Home Vitalic InfraRed Instruction Manual

Medical lamp

Advertisement

Quick Links

AIRSSENTIAL
HOME
Health Care Solutions
Vitalic
InfraRed
®
AIRSSENTIAL
HOME
Medical Lamp
Health Care Solutions
Instruction Manual
Read this manual carefully
before use to prevent
incorrect use or injury.
This manual contains
important information for
safe use of the Vitalic Infrared
Medical Lamp.
Keep this manual in a safe
place for future reference.
If you do not understand any
portion of these instructions,
contact Airssential Customer
Care Centre on 1800 026 426.
Model: AI-IRL
www.airssential.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vitalic InfraRed and is the answer not in the manual?

Questions and answers

Summary of Contents for Airssential Home Vitalic InfraRed

  • Page 1 Read this manual carefully before use to prevent incorrect use or injury. This manual contains important information for safe use of the Vitalic Infrared Medical Lamp. Keep this manual in a safe place for future reference. If you do not understand any...
  • Page 2 INSIDE FRONT COVER – BLANK...
  • Page 3: Table Of Contents

    Introduction ....................4 Statement of Intended Use ................. 4 Unpacking the Vitalic Infrared Medical Light ..........5 Parts of the Vitalic Infrared Medical Lamp ..........5 General Electrical Safety Precautions ............6 Using your Vitalic Infrared Medical Light ............ 9 Electrical Safety - Thermal Protector ............
  • Page 4: Introduction

    The Vitalic Infrared Medical Light effectively relieves aches and discomfort caused by muscular pains and joint stiffness. Use the Vitalic Infrared Medical Light as described in this manual or as recommended by your doctor. Use of this device for any other purpose is inappropriate and may be hazardous...
  • Page 5: Unpacking The Vitalic Infrared Medical Light

    Note: Retain the packaging for use in shipping or storing the lamp. Parts of the Vitalic Infrared Medical Lamp Figure 1 identifies the parts of the Vitalic Infrared light. 1. Tilting Lamp Body with Handle The tilting body allows the lamp’s adjustment to suit...
  • Page 6: General Electrical Safety Precautions

    General Electrical Safety Precautions WARNING: Improper use can be dangerous! The Vitalic Infrared Medical Lamp has been independently tested and certified to meet electrical standards. It is however important to observe the following fundamental rules to avoid electrical accidents: Do Not: • Use the lamp if the housing, ceramic filter or power cord are damaged or, if the lamp...
  • Page 7 General Safety Precautions WARNING: Risk of Burns! During use, the ceramic filter and lamp housing become very hot. To avoid the risk of burns do not: • Touch the ceramic filter or lamp housing during operation. • Exceed treatment times. Excessive exposure can result in burns. • Look directly into the lamp for extended periods during therapy. Close, look away or cover the eyes for their protection. • Use the device if the filter is damaged or missing. • Wear any metal items including necklaces, bras, jewellery or piercings from the treatment area prior to commencing therapy.
  • Page 8 Contraindications to Infrared Therapy Infrared therapy is NOT recommended in the following circumstances: Medical Conditions Do not use this device without prior medical consultation if you suffer from: • Severe cardiovascular disease and oedema • Acute inflammatory or auto-immune disease • Thrombosis, bleeding (haemorrhaging) or blood coagulation disorders • Adrenal gland suppression disorders • Malignant disease • Acute injuries where swelling or inflammation is present, as heat may aggravate the complaint.
  • Page 9: Using Your Vitalic Infrared Medical Light

    Vitalic Infrared Lamp Treatment Preparing for Treatment • Place the lamp on a solid, level surface in a vertical position standing on its base. Do not mount the lamp onto walls or ceilings as this may cause overheating. • Fully unwind the power cord before plugging into the power socket. • A clearance of 30cm from the lamp is required to prevent the risk of combustion with flammable items. Do not place the lamp on flammable materials such as tablecloths or carpet.
  • Page 10 Treatment The Vitalic Infrared Medical Lamp is versatile and can treat various parts of the body as described below: • To treat an elbow: Place the lamp on a table and adjust the lamp handle until it is directly angled at the treatment area. Sit comfortably and begin treatment.
  • Page 11: Maintenance

    Maintenance Replacing the Infrared Halogen Bulb WARNING: Danger of electric shock! Only open the lamp housing to change the halogen bulb. Do not attempt any other repair to the lamp, to avoid the possibility of harm during therapy. Procedure: 1. Ensure the lamp is cool and disconnected from the power before commencing any repair of the lamp.
  • Page 12: Troubleshooting

    Cleaning the Infrared Lamp Note: Ensure the lamp is cool and disconnected from power before commencing any cleaning of the device. • Never use scouring pads, abrasive cleaning agents or organic solvents such as petrol or acetone to clean the lamp. • Clean the lamp housing and the base with a damp cloth.
  • Page 13: Device Certification

    Device Certification The Vitalic Infrared Medical Lamp is a Class IIa Medical Device. In compliance with the European standard, this device bears the CE conformity mark 0413 authorised by Intertek Semko AB Sweden according to Annex V of the Medical Devices Directive 93/42/EEC. This device complies with the following international reference standards: • EN 60601: Medical electrical equipment...
  • Page 14: Electromagnetic Information

    Electromagnetic Field Information This complies with all standards regarding electromagnetic fields (EMF). Used in accordance with the instructions in this manual, this device provides safe therapy based on scientific evidence available today. Symbols Used in this Manual The following symbols appear in these instructions: Warning Instruction indicating a risk of injury or damage WARNING: to health...
  • Page 15: Technical Specifications

    Technical Specifications Mains connection AC 220V / 50Hz Power consumption 300 W Timer Settings from 1 to 15 minutes in one-minute intervals Dimensions (W x H x D) 198 x 186 x 295 mm Weight Approx. 1.5 kg Treatment Area 30cm x 40cm at a distance from the lamp of 30cm Operating Conditions Temperature: 10°C to 35°C Relative humidity: 50% ~ 90% Storage and Transport Temperature: -10°C to 50°C...
  • Page 16: Appendix 2

    Appendix 2 Guidance and Manufacturer’s Declaration – Electromagnetic Immunity Ensure this device should is used in the electromagnetic environment specified below. Immunity Test IEC 60601 Compliance Electromagnetic Environment - Test Level Level Guidance Electrostatic ±6 6 kV ±6 kV Floors should be wood, concrete or discharge (ESD) contact contact...
  • Page 17 Immunity Test IEC 60601 Compliance Electromagnetic Environment - Test Level Level Guidance Conducted RF 3 Vrms 3 Vrms Portable and mobile RF IEC 61000-4-6 150 kHz to 80 communications equipment Radiated RF 3 Vrms should be used no closer to any IEC 61000-4-3 3 Vrms part of this device, including 150 kHz to 80...
  • Page 18: Appendix 3: Recommended Separation Distances

    Recommended separation distances between portable and mobile RF communications equipment and the Vitalic Infrared Medical Lamp. The Vitalic Infrared Medical Lamp is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. Users of the Vitalic Infrared Medical...
  • Page 19 INSIDE BACK COVER – BLANK Vitalic Infrared Medical Lamp ®...
  • Page 20 HOME Health Care Solutions AIRSSENTIAL HOME Health Care Solutions Airssential Home Health Care Solutions 486 King Georges Road, Beverly Hills NSW 2209 Freecall: 1800 026 426 Airssential Home Health Care Solutions is a division of Boian Surgical Pty Ltd. ®...