Nebuliser
Instruction Manual
This manual contains important
information for the safe and effective use of
the Airssential AiroMax
Nebuliser System.
®
Read this manual carefully before use to understand all operational and safety information.
Keep this manual in a safe place for future reference. If you do not understand any part of
these instructions, contact the Airssential Customer Care Centre on (02) 9708 5560.
Model: A
I
-MAX
www.airssential.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AiroMax AI-MAX and is the answer not in the manual?

Questions and answers

Summary of Contents for Airssential Home AiroMax AI-MAX

  • Page 1 AiroMax AIRSSENTIAL ® Nebuliser Instruction Manual This manual contains important information for the safe and effective use of the Airssential AiroMax Nebuliser System. ® Read this manual carefully before use to understand all operational and safety information. Keep this manual in a safe place for future reference. If you do not understand any part of these instructions, contact the Airssential Customer Care Centre on (02) 9708 5560.
  • Page 3: Table Of Contents

    Contents Introduction ......................4 Statement Of Intended Use ................4 AiroMax Components and Accessories ............4 ® General Safety Precautions ................6 User Precautions ....................7 Operating Instructions ..................8 Cleaning, Disinfection, Maintenance and Storage ..........9 Cleaning ................... 9 Accessory Disinfection ..............
  • Page 4: Introduction

    Introduction Congratulations on the purchase of your new Airssential AiroMax Aerosol Therapy ® System. This device incorporates the most advanced clinical features for rapid and efficient medication delivery into the lungs. The AiroMax Aerosol Therapy System is suitable for use with all prescribed bronco-therapy ®...
  • Page 5 The Compressor Read these instructions before using the AiroMax compressor. Essential parts of the ® compressor are described in Figure 1. Face Mask On/Off Power Switch Nebuliser Bowl Air Tubing Filter Cover and Filter Ventilation Slots Compressor Air Outlet Nebuliser Bowl Holder The AiroMax Aerosol Therapy System is supplied with an Airssential nebuliser bowl.
  • Page 6: General Safety Precautions

    General Safety Precautions The Airssential AiroMax compressor has been tested and certified to meet international ® electrical standards. It is however important to observe the following rules to avoid electrical accidents: 1. Before using this device, check the integrity of the compressor pump and the accessories.
  • Page 7: User Precautions

    User Precautions 1. Do not operate the compressor on carpets or in very dusty environments (e.g. under a bed) as particulate matter from the environment may be aspirated into the lungs or cause the compressor to malfunction with extended operation. 2.
  • Page 8: Operating Instructions

    Operating Instructions The AiroMax nebuliser is supplied with a variety of accessories to allow ® treatment to be individualised to specific needs. Consult with your doctor to recommend the most suitable accessory to administer your therapy. Do not share accessories. All accessories are for single patient use only. Prior to the initial use of this equipment, clean the accessories as described in the section “Cleaning and Disinfecting”...
  • Page 9: Cleaning, Disinfection, Maintenance And Storage

    Cleaning, Disinfection, Maintenance and Storage Cleaning Follow the procedure below to clean the accessories and compressor’s housing. 1. Switch the compressor off and disconnect the power from the device. 2. Disconnect the air-tubing from the nebuliser bowl. Discard any residual medication remaining in the nebuliser bowl.
  • Page 10: Filter Replacement

    Filter Replacement Replace the air filter immediately if the filter is discoloured, damp or after a maximum of 3 months of regular usage. Do not operate the compressor without a filter installed. To change the air filter: 1. Remove the air filter cover. 2.
  • Page 11: Troubleshooting

    Troubleshooting Check the following if the device should fail during operation. Problem Possible Cause Solution Switch off the device (“O”) and insert Compressor does The power plug is the power plug properly into the not work after incorrectly inserted into the power socket.
  • Page 12: Symbols Used In This Manual

    Nebuliser System is covered by a limited warranty offered by ® Airssential Home Health Care Solutions (“Airssential”), a division of Boian Surgical Pty Ltd., to the original purchaser of this product. Proof of purchase is required to substantiate warranty claims. Airssential warrants that for a period of 5 years from the date of purchase, this product will be free from defects in material and workmanship.
  • Page 13: Technical Specifications

    Technical Specifications Compressor Name: Airssential AiroMax Nebuliser System ® Model: A I -MAX Power supply: 220V ± 22V / 50Hz Power Consumption: ≤ 70W Dimensions: 180 x 205 x 100 mm L*W*H Weight: 1.8 Kg Operation mode: Suitable for continuous use Pressure range: 300-330 kPa;...
  • Page 15: Warranty Registration

    Warranty Registration AIRSSENTIAL Coupon to be returned at time of purchase Product Purchased: ......................... Serial No. (if applicable): ......... Date of Purchase: ........Buyer Registration Name: ............................Address: ...............................................Postcode: ........Email or Phone: ........................This unit was purchased from: Name: ............................
  • Page 16 AIRSSENTIAL Airssential Home Health Care Solutions 122 Gow Street, Padstow NSW 2211 Phone (02) 9708 5560 Airssential Home Health Care Solutions is a division of Boian Surgical Pty Ltd. ® Airssential and AiroMax are the registered trademarks of Boian Surgical Pty Ltd.