Planning

Survey your garage area to see if any of the conditions
below apply to your installation. Additional materials may
be required. You may find it helpful to refer back to this
page as you proceed with the installation of your opener.
Depending on your requirements, there are several
installation steps which may call for materials or
hardware not included in the carton.
This opener is compatible with:
• Doors that use a torsion bar, springs and a door no
more than 14' (4.2 m) high.
• 4"-6" (10 cm - 15 cm) drums, not to be used on
tapered drums over 6" (15 cm).
• High lift and standard lift sectional doors up to 14'
(4.2 m) high.
• Doors up to 18' wide.
• Doors up to 180 sq. ft.
• 1" (2.5 cm) torsion bar only.
• Review or inspect proposed installation area. Opener
can be installed on left or right side of door. Select the
side that meets the requirements listed below.
- Must have minimum of 2-1/2" (6.4 cm) between the
garage wall and the center of the torsion bar.
- Must have minimum of 3" (7.6 cm) between the
ceiling and the center of torsion bar.
- Must have minimum of 8" (20.3 cm) between the
side garage wall (or obstruction) and the end of
torsion bar.
Motor unit
Power
Door Lock
Safety
Reversing Sensor
Cable Tension
Monitor
Gap between floor
and bottom of door must not exceed 1/4" (6 mm).
• The torsion bar must extend at least 1" to 5"
(2.5 cm to 12 cm) past the bearing plate.
• An electric outlet is required within 6' (1.8 m) of the
installation area. If outlet does not exist, contact a
qualified electrician.
• Depending upon garage construction, extension
brackets or wood blocks may be needed to install
safety reversing sensors.
• Alternate floor mounting of the safety reversing
sensors will require hardware not provided.
• A model 475LM EverCharge
is strongly recommended if there is no access door to
the garage, as this opener cannot be used in
conjunction with an external emergency release
mechanism.
• Any gap between the floor and the bottom of the door
must not exceed 1/4" (6 mm). Otherwise the safety
reversal system may not work properly.
NOTE: Inspect the torsion bar while the door is raised
and lowered. It is important that there is no noticeable
movement up and down or left and right. If this type of
movement is not corrected, life of this opener will be
greatly reduced.
Remote Light
Torsion Spring
Drum
Access Door
Safety
Reversing
Sensor
3
TM
Battery Backup System
Wall-mounted
Control Console

Hide quick links: