Wisy ZETA 02 Instructions For Installation And Operation Manual

Automatic transmission
Hide thumbs Also See for ZETA 02:

Advertisement

Machine Translated by Google
k
• For all common
pumps can be used
• Reduction of
CO2 emissions by
up to 97%
• Energy savings of up
to 128 kWh/
Year
• Energy cost savings
of up to 32,- E per year
• ZETA 02 switches
the pump
on and off as
needed and
protects the pump from
dry running
•Deutsches
utility model
DGM 2020 13011
190.9
• energy-efficient and
programmable
electronics,
Standby less than 0.2
watts
Instructions for installation and operation
Z
ZETA 02
WISY
rainwater harvesting
automatic transmission
ZETA 02
valid from number ZT 17 1
automatic transmission
Original
WISY-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZETA 02 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wisy ZETA 02

  • Page 1 97% • Energy savings of up to 128 kWh/ Year • Energy cost savings of up to 32,- E per year • ZETA 02 switches the pump on and off as needed and protects the pump from dry running •Deutsches...
  • Page 2 Machine Translated by Google ZETA 02 automatic gearshift Installation and use requires detailed knowledge of these operating instructions! Installation instructions and technical information for the highly efficient WISY pump controls ZETA 02 and ZETA 02/V key to symbols Failure to follow Failure to...
  • Page 3: Safety Instructions

    These operating instructions must be read carefully and kept for future reference. The supply voltage for ZETA 02 must be between 100 V and 240 V (50 Hz / 60 Hz). Please check whether the pump connected to ZETA 02 is suitable for the existing mains voltage! ZETA 02 must never be lifted or pulled by the power cable.
  • Page 4 The WISY pump control ZETA 02 is equipped with: ÿ integrated Schuko socket ÿ 1.5 m long power cable with Schuko plug ÿ only ZETA 02/V: Adjustment screw for switch-on pressure (top ÿ Input external thread: 1” (bottom ÿ Output external thread: 1” (side ÿ...
  • Page 5: Installation Requirements

    (ready-to-use light, power). If the pump is no longer supplied with enough water during operation, ZETA 02 registers the lack of water flow and the pump is switched off. If the tap is still open, the pump starts again automatically twice after 10 seconds each, then twice after 3 minutes each and then 48 times at one-hour intervals.
  • Page 6 Switching to programming mode: If the reset button is pressed and held, all three LEDs light up after 6 seconds. After a total of 10 seconds, Zeta 02 is in programming mode 1 (green LED flashes quickly). To get to programming mode 2, the reset button must be pressed for a total of 20 seconds (green LED flashes slowly).
  • Page 7: Expansion Tank

    Machine Translated by Google Pump stop during cycles (more than 25 starts / hour) / pump stop during continuous operation (longer than 10 minutes) Mode 2 - LED Power (green) flashes slowly Press the reset button for 20 seconds until the Power LED (green) changes to the slower flashing mode. Release the button.
  • Page 8: Maintenance & Repair

    For ZETA 02/V to function properly, the pump must be able to achieve a delivery head 8 m (0.8 bar) higher than the set switch-on pressure.
  • Page 9: Troubleshooting Tips

    The pump constantly a) Leak in the system. a) Process water network according to switches on and off. Check ZETA 02 for water losses due to unclosed or dripping taps, toilet flushing systems that do not close and broken garden hoses, close taps or replace them.
  • Page 10 Disposal / recycling of transport packaging The packaging of the ZETA 02 is recyclable and can be recycled as waste paper! Disposal / recycling of the old device Old electrical and electronic devices often still contain valuable materials that can be reused. However, they also contain harmful substances that were necessary for the device to function and be safe.
  • Page 11 Machine Translated by Google Due to its structure, technology and design, the control unit ZETA 02 / ZETA 02/V complies with the requirements of the following EC directives: Directive 2004/108/EC on the electromagnetic compatibility of electronic products in the version of 15 December 2004...
  • Page 12 Machine Translated by Google WISY AG D-63699 Kefenrod, Oberdorfstraße 26 Telephone +49 (0) 60 54-91 21 - 0, Fax +49 (0) 60 54 - 91 21-29 Internet: www.wisy.de • E-Mail: info@wisy.de...