400 SERIES 400 SERIES -Pre-Installation Check List- PLEASE NOTE THESE SPECIFICATIONS BEFORE PROCEEDING A water test should always be performed in order to determine total water hardness (in gpg) and total dis- solved iron (in parts per million - ppm). This is critical for proper equipment selection, sizing and for deter- OPERATING PRESSURE RANGE : 20 - 125 PSI mining the program for regeneration frequency.
400 SERIES 400 SERIES -Installation Procedure- - Water Supply Connections and Bypass Valve - To allow for softener servicing, swimming pool filling or lawn sprinkling, a manual bypass valve has been in- stalled at the factory. The bypass allows hard water to be manually routed around the softener.
400 SERIES 400 SERIES - Electrical Connection - - Electrical Connection and Battery Back Up- 1. Connect the power cord and plug power supply into a 115 volt / 60 Hz receptacle. 1. Connect one end of power supply into a power cord and the other end into a 115 volt / 60 Hz receptacle.
400 SERIES 400 SERIES - Programming The Control Valve - -Start Up Procedure- Main Menu MENU / ENTER 1. Put unit in bypass using the handles behind the control valve. BUTTON 12:00 2. Start a regeneration by pressing and holding the set change button for 3 seconds.
Page 7
400 SERIES 400 SERIES Start Up Procedure - Final Check - 1. Be certain the bypass valve is in the SERVICE position. 2. Make sure the power supply is connected to an uninterrupted 115-volt outlet. Starting Extra Regeneration Cycle 3. Check that the time of day is set 4.
400 SERIES 400 SERIES Utilizing Bluetooth Control Master Programming Mode To enter Master Programming Mode, press and hold both buttons for 5 seconds. Note: All Master Programming functions have been preset at the factory. Unless a change is desired, it is NOT necessary to enter Master Programming Mode.
400 SERIES 400 SERIES Status and History Change Time of Day (Press “SET” to set time automatically based on device). From the Status and History, all items in ORANGE can be reset. Pressing this icon will show a list of...
Page 10
400 SERIES 400 SERIES Part No. Description Price Ea Front Slide Cover $3.50 Electronics Board SD-1 Encoder SC8 Screw Motor Assembly Drive Plate $2.02 Axial Drive Assembly $5.30 Piston Rod O-Ring Retainer Piston Rod Seal Cam Gear $0.32 Base Plate $2.24...
Page 11
400 SERIES 400 SERIES DESCRIPTION PART NO. Piston Assembly 20018X231 Pinion Gear SS 304 Screw SC12 Seal and Spacer Kit 20561X253 End Spacer 20001X234 40470X001 Flow Control Button 1.5 GPM 20251X266 (Top Cap Cabinet) Flow Control Button 2.0 GPM 20251X267 Flow Control Button 2.4 GPM...
400 SERIES 400 SERIES General Preliminary Instructions PERFORM BEFORE ALL SERVICING OPERATIONS 1. Turn off water supply to conditioner. -If the conditioner installation has a “three valve” bypass system, first open the valve in the bypass line, then close the valves at the conditioner inlet and outlet.
400 SERIES 400 SERIES SYMPTOM PROBABLE CAUSE CORRECTION To Service Injector and Screen Power supply plugged into Connect to constant power source 1. Follow steps A1-A2. intermittentent or dead power 2. Unscrew injector cover screws and remove injector cover. 1. Softener Fails to source 3.
Page 14
400 SERIES 400 SERIES SYMPTOM PROBABLE CAUSE CORRECTION Control Valve Error Code Diagnosis Plugged drain line or drain line con- Check flow to drain. Clean drainline Under normal operating conditions, when your control valve is in the “in service” position, the display should...
Purchasers who buy the ClearionWater Treatment Systems is given to an authorized Clearion Dealer or to Clearion or a equipment for other purposes, and other component parts are designated contractor is provided access to the installation subject to more limited warranties and you should read all of the and to the water treatment equipment.