Contents Product liability and warranty ............5 1.1 General ........................ 5 1.2 Warranty ......................5 1.3 Intended purpose ....................6 1.4 Service ......................... 8 1.5 Symbols and Pictograms ................... 8 Safety ....................9 2.1 Selection of the installation site ................ 9 2.2 Risks relating to electrical energy ..............
Page 3
5.4.3.2 Setup or change your own parameters externally (option)........29 5.4.3.3 Select your own tool parameters ................29 5.4.4 List of most used tools: FAVORITES ..............30 Configuration ..................31 6.1 Switching between mm/ inch ................32 6.2 Setting up and configuration of cooling time ..........32 6.2.1 Setting up of cooling time ..................32 6.2.2 Configuration of cooling time ................33 Configuration of cooling time for “parameter shrinking”...
Product liability and warranty Product liability and warranty General These operating instructions are part of the technical documentation for the ThermoGrip induction device ISG2410 / ISG2430. These operating instructions are important so that the device can be used safely, correctly and efficiently.
Product liability and warranty Intended purpose The ThermoGrip induction device ISG2410 / ISG2430 is used for the thermal engagement and disengagement of tools in shrink chucks. Any other use above and beyond this is deemed not in accordance with the intended use. We will not be liable for any resulting damage.
Page 7
Product liability and warranty Place for ferrite discs and tool holders Guiding unit Tool holder Coil Coolant cooler Control panel Guiding unit Coil Control panel Place for ferrite discs and tool holders Tool holder Air cooler Fig. 3 ThermoGrip Induction unit ISG2430-TLK 02/2024 ISG2410 / ISG2430 V3.5...
Product liability and warranty Service We will be happy to help solve problems or perform repairs and modifications that are not described in these operating instructions. For problems or queries, make note of the device and generator serial numbers. The device serial number can be found on the type plate on the left side panel, the generator serial numbers is on the right side of the black generator box.
Safety Safety The induction generator has been built to comply with the state-of-the-art design at the time of delivery and is safe to operate. Nevertheless, there are still risks involved with operating the device if it is used by untrained or unqualified personnel or if it is not used as intended. Therefore, must be observed: Please read the operating instructions carefully and familiarize yourself with the operating elements before commissioning and using the device!
Safety Risks from hot parts The very effective heating function only heats the relevant surface zones of the chuck with the lowest heat input possible. The surface of the heated chucks reaches temperatures of up to 400°C. The coil and the cutting tool hardly heats up at all when operated properly. Caution! Risk of injury caused by burns from hot parts! As a result of the shrinking process the heated tool assembly radiates heat.
Safety Risks relating to electromagnetic radiation If used correctly, the device does not emit any electromagnetic radiation that is dangerous to its environment. The radiation safety of the system is checked and verified through tests performed in accordance with EC Machinery Directive (see 10.6, EC Declaration of Conformity, page 50). The shrinking process must not be operated without the ferrite disc being inserted! If the induction heating is started when there is no ferrite disc being inserted in the coil, the...
Controls and commissioning ISG2410 / ISG2430 Controls and commissioning ISG2410 / ISG2430 Assembly Caution: Please inspect the unit for shipping damages prior to assembly. Ensure that the unit is not damaged during the unpacking process. In particular, the cable system must not be bent or twisted out of its position of movement! Handle the unit with care.
Controls and commissioning ISG2410 / ISG2430 3.1.2.2 Mounting the guide unit Place the guide unit sub-assembly in the bores and fasten with the two enclosed screws (DIN912 M6x20, see Fig. 5). The PE screws at the side must be fastened tightly. (Fig. 6) Fig.
Controls and commissioning ISG2410 / ISG2430 3.1.2.5 Connecting the compressed air supply Compressed air must be oil-free! The compressed air supply must be connected properly to the unit. The pneumatic connection of the ISG2410-WK is located on the left hand side. Fig.
Operating the ISG2410 / ISG2430 Operating the ISG2410 / ISG2430 Operating buttons All the work and adjustment processes are carried out at the operator panel using 7 keys: Button name in Button Function text START Start Start the inductive heating of the shrink-fit chuck Stop the inductive heating of the shrink-fit chuck Acknowledge error messages Stop...
Operating the ISG2410 / ISG2430 Switching on the device ➢ Switch on the main switch The display shows the type of the machine. Now you are in the main menu. Shrinking Configuration Service The ISG2430-TWK / ISG2430-TLK is ready for use now. At ISG2410-WK please note: After selecting Shrinking or Service and pressing the OK button, the compressed air is switched The linear unit moves down initially and then upwards.
Shrinking Shrinking Basic shrink-fitting information Only tools with a ground shank and tolerance h4, h5 or h6 should be used. Tools with shank tolerance h7 cannot be securely clamped. The following shank tolerances are required for the various shank diameters: Shank Ø...
Shrinking Work sequences when clamping or releasing a tool For your own safety, please observe the following rules when working with the ISG2410 / ISG2430: Always observe the safety instructions for all shrink-fit processes! At ISG2430-TWK, after finishing the shrinking procedure, the cooling down must be operated manually through pressing the Cool button.
Shrinking 5.2.2 Clamping By pressing on the tool during the subsequent heating phase you assist the clamping process. If the tool has been inserted and the shrinking time has not yet ended, it is helpful to end the heating process with the Stop button, so as not to continue to heat the tool unnecessarily. After the selected shrinking time runs out or the Stop button is pushed, the coil is brought to the upper end position (ISG2430-TWK / ISG2430-TLK) and the cooling device is pulled upwards (ISG2430- TWK).
Shrinking Shrink-fit operating modes Parameter Manual Tool memory Favorites PARAMETER MANUAL TOOL MEMORY FAVORITES …, if you use a …, if you use another …, if you use chuck of …, if you use a table of chuck or tool and want your own with shrinking the most shrunk tools.
Shrinking 5.4.1 ThermoGrip clamping chucks: PARAMETER The necessary parameters for the ThermoGrip chuck such as the generator output power, heating period, cooling time and disc sizes for the chuck type are programmed in the factory equipment of the ISG2410 / ISG2430 (see 5.4.1.1, Table of factory defined parameters, page 23). Attention: Special ferrite discs for TSF and TER shrink-fit chucks are necessary (see Fehler! Verweisquelle konnte nicht gefunden werden.
Page 22
Shrinking Step 3: Additional options Select with up ▲ and ▼ down additional options and activate or deactivate with OK. The status (bottom line) shows the type of chuck and the assigned shrinking time and output power. The blinking symbol shows the device is ready for shrinking Following options are possible for ISG2410-WK: Deselecting the automatic cooling, This option is always set active after every...
Shrinking 5.4.1.1 Table of factory defined parameters T- chucks (Standard Type according to DIN69882-8) Designation of chuck Txxxx -range -range Ferrite disc Shrinking time Shrinking output in sec power in % in mm in inches ISGS2201-1 5/32 ISGS2201-1 3/16 ISGS2201-1 ISGS2201-2 5/16 ISGS2201-2...
Page 24
Shrinking TER Shrink collets, geometry according ER 11 Designation Ferrite disc Time Power Dwell time in sec in % in sec in mm in inches TER0300/11 ISGS2201-TER11-1 TER0400/11 ISGS2201-TER11-1 5/32 TER0600/11 ISGS2201-TER11-1 TER Shrink collets, geometry according ER 16 ...
Shrinking Shrinking with free “Parameter” selection: MANUAL 5.4.2 This mode is intended for shrinking special tools or special clamping chucks, which only occur in seldom cases. Furthermore, this mode can be used to set the shrinking parameters for frequently used special chucks or tools. Parameter Manual Tool Memory...
Page 26
Shrinking Following options are possible for ISG2410-WK: Deselecting the automatic cooling, This option is always set active after every shrinking. Other options see Chapter 6.2, Setting up and configuration of cooling time, page 32 Start Delay Delay of the beginning of the shrinking. See Chapter 6.3, Enter Start Delay (ISG2410-WK only), page 34 Stop Delay (Dwell time) Delay of the beginning of the cooling process.
Page 27
Shrinking ➢ Especially for smaller tools, do NOT increase the heating time by one second at the same power setting. Instead, increase it by 1s and reduce the output power by 20% at the same time. The product of power x time is the energy input. If a cycle at 3s and 100% (3x1=3) is not successful, increase to 4s/ 80% (4*0.8=3.2) and so forth.
Shrinking 5.4.3 Define your own Parameters: TOOL MEMORY 5.4.3.1 Setup TOOL MEMORY at the machine At the beginning, a similar standard chuck is selected from the existing parameter list. Start with mode PARAMETER similar to standard shrinking (see Chapter 5.4.1, ThermoGrip clamping chucks: PARAMETER, page 21). It is important to define the disc for the new chuck.
Shrinking 5.4.3.2 Setup or change your own parameters externally (option) With the PC based program „ToolMemoryEditor“ you can define tools by yourself and read into the control with an USB memory stick. The USB interface is located at the generator module on the right side. Read in the generated file of tools: ➢...
Shrinking 5.4.4 List of most used tools: FAVORITES A top-ten list of the most used tools is directly available with the function „Favorites“. Select with up ▲ and ▼ down the function "FAVORITES" Activate with OK. A list of the most used tools appears Select with up ▲...
Configuration Configuration With multiple pressings of ESC you come to the main menu. Shrinking Configuration Service Select with up ▲ and ▼ down the function Configuration and activate with OK. If the Configuration is protected by a password you have to enter it first. How to activate/ deactivate the password see Chapter 6.6, Password on/ off or change, page 35 You can increase or decrease the numbers with up ▲...
Configuration Switching between mm/ inch The diameter of the tool can be shown on the display in mm or in inches. Select the desired unit with up ▲ and ▼ down and confirm with OK. Setting up and configuration of cooling time If only the symbol „cooling“...
Configuration 6.2.2 Configuration of cooling time The cooling function can be configured differently for the "parameter shrinking" and / or "manual shrinking" functions. Select the functions with up ▲ and ▼ down and activate with OK. The active function is marked with and confirmed with OK.
Configuration Enter Start Delay (ISG2410-WK only) Around 3 seconds will pass before the generator starts. If this waiting time is too short to insert bulky tools, the Start Delay option can be used to set an additional delay of up to 30s. Select the desired value with up ▲...
Configuration Password on/ off or change Entering "0000" will switch off the password. This is the factory default. Whenever you enter a value unequal to "0000" you switch on the password request. You can enter a password of your choice with up to 4 decimal figures (for e.g.: 3480).
Configuration Lock shrinking operations With the ISG2410 / ISG2430, it is possible to lock the functions “Manual shrinking” and / or “Parameter shrinking” for the operator using a password. The function is only applied when ThermoGrip shrink-fit chucks are used and any overheating occurs as a result of an operating error of the operator must be excluded.
Service Service With multiple pressings of ESC you come to the main menu. Shrinking Configuration Service Select with up ▲ and ▼ down the function Service and activate with OK. Information about the shrink unit Type equipment designation Generator number of the generator installed EEPROM version of the variable memory Software...
Cleaning and Servicing Cleaning and Servicing Maintenance / Visual Inspection Every 6 months, check mains cable for damage (visual inspection), the function of protected earth PE and the earth leakage circuit breaker (GFI, GFCI). To check the GFCI, switch on the pump (see Chapter 7, Service, page 37). Cleaning The unit must be cleaned regularly.
Cleaning and Servicing Filling/ draining the cooling emulsion 1 liter of cooling concentrate (one initial tank filling) is provided with the unit. In general, your plant cooling emulsion with similar contents can be used. Only fill in in an empty and clean tank. 8.3.1 Filling the coolant tank (ISG2430-TWK) Move away flexible cover...
Cleaning and Servicing Checking the float switch ➢ Whenever the coolant is changed, the function of the float switch must be checked. The float must move freely and it will sag down by its own weight, when the coolant tank is empty.
Appendix Appendix 10.1 Error messages and corrective measures Hints are displayed as follows: <Number> Hints serve as information for the operator and can be acknowledged using the Stop button! Errors are displayed as follows: <Number> After troubleshooting, the displayed error can be acknowledged using the Stop button! Errors must only be rectified by trained personnel! Number Type Message...
Page 43
GFCI switch of pump has Turn on GFCI switch 2.42 defective (Version with been released Replace pump Opto-Coupler) Bilz-Reader not No reader connected Connect reader to USB 2.44 recognized on the USB Wrong or defective interface or change it interface...
Page 44
Appendix Number Type Message Possible cause Corrective measures No database connected Connect database Connection to database Connection disturbed 2.46 Check Connection failed Defective Ethernet Change hardware interface Data record from data Create data record for Data carrier ID not found 2.47 carrier has not yet been data carrier ID in the...
Appendix 10.3 Scope of supply Shrinking Unit ISG2410 / ISG2430 incl. coil and 3 ferrite discs, clamping ring, gloves as well as 1 liter coolant concentrate (corresponds to a complete filling of the coolant tank). Ferrite discs one-piece For an optimal shielding of the magnetic field between coil and tool shank Clamping- Ø...
10.3.1 Available additions and optional accessories Expansion options and optional accessories can be found on our homepage or in our product catalogs. www.bilz.de If you have any further questions, please contact your sales representative. 10.3.2 Service pump The service pump can be used to drain the cooling tank of shrink machines with water cooling.
Appendix 10.4 Instructions Safety Glove Description: Heat protection glove, outer layer consisting of para aramide yarn (KEVLAR) Fine knitted fabric lined with aramide felt and 100% Nornex knitted fabric Availability: Size 10 Color: yellow Manufacturer: JUTEC GmbH, Mellumstr. 23-25, D-26125 Oldenburg Description: These gloves have been designed to protect your hands.
Appendix 10.5 Mains Connections Allocation of the CEE socket Pin name Pin designation Wire colour Phase L1 Brown Phase L2 Black/ grey Phase L3 Black Neutral Blue Ground Green-yellow The nominal voltages between the phases are 3x400V (-10/ +10%) The nominal voltage between a phase L1, L2 or L3 and neutral is 230V (-10/ +10%) Further hints: ➢...
EC Declaration of Conformity In accordance with the EC Machinery Directive 2006/42/EC Bilz Werkzeugfabrik GmbH & Co. KG declares, that the machine designated below corresponds to the following relevant directives with regard to its design and construction in the version brought into circulation.
Appendix 10.7 Safety Data Sheets All safety data sheets for the hazardous substances supplied are available on request. 02/2024 ISG2410 / ISG2430 V3.5...
Appendix 10.8 Table of Fuses for 208V units Fuse Phases Rated Voltage Rated Current Frequency Dimensions Tripping Characteristic Location 250V 3.15A 50/60 Hz 5x20 mm fast acting Distribution board 250V 3.15A 50/60 Hz 5x20 mm fast acting Distribution board 250V 3.15A 50/60 Hz 5x20 mm...