SPECS
Size: 3.5" x 1.5" x 12.75" (40.3 x 38 x 324 mm)
Max Cart Size: 0.5" x 2.4" (14 x 62 mm)
Battery Capacity: 650 mAh
Voltage: 1.8 - 4.2 V (1.8 V Pre-heat)
Charging: USB-C
Resistance: ≥0.8
KIT INCLUDES
1x Pulsar 510 Wizard Pipe Battery
1x Regular Length Stem Cover
1x Wizard Extended Length Stem Cover
1x USB-C Charging Cable
POWER ON/OFF
Before using the Wizard Pipe, fully charge the device using a USB-C charging cable and a standard charging brick.
You will see the LED and screen turn on when the battery is charging. Allow the battery to fully charge before the
first use. When the battery indicator reaches 100%, the device is fully charged and can be unplugged. To power the
device on and off, quickly press the screen (button) 5 times. It enters a standby mode after 10 seconds of not being
used. To wake the device up, press the button 1 time and the screen will turn on and show the current voltage and
puff count. You can also pull from the mouthpiece and the device will be ready to vape.
INSERT CARTRIDGE
With the mouthpiece pointing towards you, twist counterclockwise and pull to remove the stem cover and firmly
screw in the 510-threaded cartridge of your choice. Place the stem cover back over the cartridge and twist it
clockwise to secure the stem.
PRE HEATING
Press the button 2 times to activate the pre-heat function. It will run at 1.8 V for 8 seconds. This function will be
indicated by the flame icon lighting up and blinking. When the timer is fully lit, the pre-heat function is complete.
CHANGE VOLTAGE SETTINGS
Press the button three times to change the voltage settings. The voltage display will begin blinking to show it is
ready to be changed. Once the voltage display is blinking, you can press the button once to cycle through the
voltage setting 1.8 - 4.2 V in 0.1 increments or long press the button and the voltages will cycle through. Once you
have reached your desired voltage, wait for the voltage to stop blinking and it will be set.
CHARGING
Charging will be indicated by the battery's semicircle blinking and the lightning bolt flashing. When the device is fully
charged the battery indicator will read 100% and the flashing lightning icon will stop. When the battery life has fully
expired the light ring will flash red 10 times and enter standby mode to let you know it needs to be charged before
it's used again.
Puff Count Reset: Quickly press the button three times and hold the button on the third press to reset the Puff
Counter to 0000.
PROTECTION FEATURES
Over-voltage/short-circuit protection: When the cartridge resistance is lower than 0.8 ohms, the red light flashes 3
times and the system enters standby mode. The red light flashes 3 times to turn off the output.
CLEANING INSTRUCTIONS
Remove the stem cover from the battery. Use an alcohol swab to wipe any excess residue out of the 510
connection. Clean inside the air pathway with an alcohol swab. Using a circular motion, work your way up and down
the air pathway until you do not see any more oil.
Do not submerge any part of the device in a cleaning solution. Allow all parts to air dry prior to reassembly.
WARNINGS
Do not expose to extreme temperatures or direct sunlight. Do not drop the device or accessories. Do not drop or submerge in any
liquid. Do not modify the electronics in any way. This device is intended for adults only. Do not sell or provide to minors. Keep all
parts, concentrates, herbs, and liquids away from children and pets. This is not a medical device and is not intended to diagnose,
treat, mitigate, cure, or prevent any ailment, disease, or other conditions. Consult a physician before use, especially if you suffer
from heart disease or any other medical condition, or if you are pregnant or breastfeeding. Failure to follow any of these
instructions could result in product damage, property damage, personal injury, and may void warranty.
Visit
PulsarShop.com
for warranty information.
INSTRUCTION
MANUAL
POWER BUTTON/
DIGITAL DISPLAY
SCREEN
WIZARD STEM
MOUTHPIECE
STANDARD STEM
MOUTHPIECE
PulsarShop.com
PU-0778-24

Advertisement

loading
Need help?

Need help?

Do you have a question about the 510 DL WIZARD PIPE and is the answer not in the manual?

Questions and answers

Summary of Contents for Pulsar 510 DL WIZARD PIPE

  • Page 1 SCREEN Resistance: ≥0.8 STANDARD STEM MOUTHPIECE KIT INCLUDES 1x Pulsar 510 Wizard Pipe Battery 1x Regular Length Stem Cover 1x Wizard Extended Length Stem Cover 1x USB-C Charging Cable POWER ON/OFF Before using the Wizard Pipe, fully charge the device using a USB-C charging cable and a standard charging brick.
  • Page 2 INSTRUCTION MANUEL TIGE   D E   M AGICIEN EMBOUCHURE CARACTÉRISTIQUES   T aille :   3 ,5"   x    1 ,5"   x    1 2,75"   ( 40,3   x    3 8   x    3 24   m m) Taille   m aximale   d u   c hariot :   1 4   x    6 2   m m   ( 0,5"   x    2 ,4") Capacité  ...