NAVAC NMV1S User Manual

Premium micron vacuum gauge

Advertisement

Available languages

Available languages

Quick Links

NMV1S
Premium Micron Vacuum Gauge
User Manual
Failure to follow warnings could
result in physical injury.
SAVE THIS MANUAL
FOR FUTURE REFERENCE
Empowering you to work smarter
CERTIFICATIONS
1.1 FCC 15.19 Labelling requirements (All other devices)
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
1.2FCC 15.21 Information to user
Please note that changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
1.3FCC 15.105 Information to the user (Class B)
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
—Consult the dealer or an experienced radio/TV technician for help.
1.4RF exposure statement
This equipment complies with radio frequency exposure limits set forth by the FCC for an
uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 cm between
the device and the user or bystanders.
This device must not be co-located or operating in conjunction with any other antenna or
transmitter.

Advertisement

loading
Need help?

Need help?

Do you have a question about the NMV1S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NAVAC NMV1S

  • Page 1 Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause NMV1S undesired operation. 1.2FCC 15.21 Information to user Please note that changes or modifications not expressly approved by the party responsible Premium Micron Vacuum Gauge for compliance could void the user’s authority to operate the equipment.
  • Page 2: Operation

    Empowering you to work smarter Empowering you to work smarter INSTRUMENT OVERVIEW TECHNICAL SPECIFICATIONS Model NMV1S Location Indoor use Altitude ≤5000m Indicator light ≤75% R.H. Humidity Intended Use Pressure Measurement 50 psi / 3.4 bar Maximum Overload Pressure Display area 0~25000 microns, 0~3333.3 Pa, 0~33.3 mBar,...
  • Page 3 4.3. Both evaluation target and delayed target are set to off all alarm prompts will not be triggered. 5. Zero setting calibration Under the atmosphere, press and hold “ ”at same time for more than 2 seconds until the vacuum display area displays "-------", the full calibration is completed. ©NAVAC Inc. - All Rights Reserved...
  • Page 4 Cet appareil est conforme à la partie 15 des règlements de la FCC. Son fonctionnement est soumis aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d'interférences nuisibles, et NMV1S (2) Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant causer un fonctionnement non désiré.
  • Page 5 Empowering you to work smarter Empowering you to work smarter APERÇU DE L'INSTRUMENT SPÉCIFICATIONS TECHNIQUES Modèle NMV1S Lieux Utilisation intérieure Altitude au - dessus du niveau de la mer ≤5000m Voyant lumineux ≤75% R.H. Humidité Utilisation prévue Mesure de pression 500 psi / 34.5 bar...
  • Page 6 5. Calibrage du réglage zéro Sous pression atmosphérique, appuyez et maintenez " " en même temps pendant plus de 2 secondes jusqu'à ce que la zone d'affichage du vide affiche "-------", l'étalonnage complet est terminé. ©NAVAC Inc. - Tous droits réservés...