Advertisement

Available languages

Available languages

Quick Links

psi
psi
bar
bar
Oct
Oct
Trinkwasserfilter/Water filter
psi
psi
bar
bar
Oct
Oct
Apr
Apr
Apr
Apr
RFF24P/RFF24
Installation/User Manual
psi
psi
bar
bar
psi
psi
Oct
Oct
Apr
Apr
bar
bar
Oct
Oct
Apr
Apr
Deutsch
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RFF24P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Magnetic RFF24P

  • Page 1 Deutsch English RFF24P/RFF24 Trinkwasserfilter/Water filter Installation/User Manual...
  • Page 2: Table Of Contents

    DEUTSCH RFF24P/RFF24 Allgemeines, Sicherheitshinweise, Haftungsausschluss, Einsatzgebiet ......Daten & Maße ........................... Hauswasserstation (RFF24P) ......................Rückspülfilter (RFF24) ........................Einbau ..............................Hinweise ............................Montage ............................Inbetriebnahme ..........................Hinterdruck-Einstellung ......................... Rückspülen ............................Instandhaltung ..........................Druckminderer ..........................Filter ..............................Service & Zubehörteile........................Entsorgung ............................
  • Page 3: Allgemeines, Sicherheitshinweise, Haftungsausschluss, Einsatzgebiet

    Schäden, einschließlich Folgeschäden, die aus falscher Installation oder falschem Gebrauch des Produktes ent- stehen können. Einsatzgebiet Die magnetic Filter sind bestens für den Einsatz im Trinkwassersystem geeignet. Der maximal Vordruck liegt bei 16 bar. Der Hinterdruck kann zwischen 1,5  bis 6 bar nach eigenem Bemessen eingestellt werden. www.magnetic-online.de...
  • Page 4: Daten & Maße

    DEUTSCH RFF24P/RFF24 Daten & Maße | Hauswasserstation RFF24P Länge in mm DN25 DN32 Daten und Maße | Rückspülfilter RFF24 Länge in mm DN25 DN32 www.magnetic-online.de...
  • Page 5: Einbau

    DEUTSCH RFF24P/RFF24 Der richtige Einbau Hinweise › Die Montage des Filters ist in waagrechten als auch senkrechten Rohrleitungen möglich. › Den Einbau zweier Absperrhähne mit einplanen. › Achten Sie darauf, dass der Filter leicht zugänglich ist, sodass der Manometer und der Verunreinigungsgrad der Filtertasse ersichtlich sind.
  • Page 6: Inbetriebnahme

    DEUTSCH RFF24P/RFF24 Inbetriebnahme Hinterdruck-Einstellung › Den Absperrhahn vor dem Filtereingang schließen. › Ausgangsseitig den Druck (bspw. durch Wasserentnahme) reduzieren. › Ausgangsseitigen Absperrhahn schließen. › Mittels Schraubenzieher die Schraube am Regler lösen (nicht komplett herausdrehen). › Druckfeder durch Drehung des Druckminderer-Reglers gegen den Uhrzeigersinn bis Anschlag entspannen.
  • Page 7: Rückspülen

    DEUTSCH RFF24P/RFF24 Rückspülen › Eingangsdruck von mindestens 1,5 bar gewährleisten. › Die Rückspülung ist nur mit montiertem Wasserauslass möglich. › Empfehlung: Rückspülung 1x monatlich durchführen. › Bei fehlender Rückführung des Spülwassers einen Auffangbehälter unter den Filter stellen. › Rückspülknopf gegen den Uhrzeigersinn bis Anschlag drehen.
  • Page 8: Instandhaltung

    DEUTSCH RFF24P/RFF24 Instandhaltung Druckminderer › Zeitintervall: 1 bis 3 Jahre. › Eingangsseitige Absperrarmatur schließen. › Druck ausgangsseitig ablassen. › Absperrhahn am Ausgang absperren. › (1) Schlitzschraubenzieher in die seitlichen Vertiefungen der Haube drücken. › Sobald alle Schnappverbindungen gelöst wurden, unteres Gehäuse abnehmen.
  • Page 9: Filter

    DEUTSCH RFF24P/RFF24 Instandhaltung Filter › Zeitintervall: alle 2 Monate. › Führen Sie regelmäßig die Rückspülung durch (siehe Seite 7). Das Unterlassen des Rückspülprozesses kann zu einer Verstopfung des Filter führen. Hieraus resultiert ein Abfalls des Drucks und sinkender Durchfluss des Wassers.
  • Page 10: Störungen & Fehlerbeseitigung

    DEUTSCH RFF24P/RFF24 Störungen & Fehlerbeseitigung Hauswasserstation (RRF24P) Störung Fehlerbeseitigung Kein bzw. zu niedriger Prüfen Sie, ob die vor bzw. nach dem Filter installierten Absperrhähne komplett geöffnet sind. Wasserdruck Prüfen Sie, ob am Filtersieb Verschmutzungen erkennbar sind. Falls vorhanden, Filter wie auf Seite 7 beschrieben, rückspülen.
  • Page 11: Explosionszeichnung

    DEUTSCH RFF24P/RFF24 Explosionszeichnung Pos. Bezeichnung Verstellgriff Federhaube Gleitring Feder (Druckminderer) Ventileinsatz Dichtscheibe Düsenkante Sieb Manometer oberes Gehäuse Nutring Führungsstück O-Ring Impeller Filtereinheit Feder (Filtereinheit) Filtertasse inkl. Rückspülregler unteres Gehäuse inkl. Kalenderdrehknopf O-Ring (Ablauftrichter) Ablauftrichter www.magnetic-online.de...
  • Page 12 ENGLISH RFF24P/RFF24 General information, safety instructions, liability disclaimer, area of use ..... Data & dimensions ......................... Domestic water station (RFF24P) ....................Backwash filter (RFF24) ........................ Installation ............................Instructions ............................ Assembly ............................Commissioning ..........................Outlet pressure adjustment ......................Backwashing ..........................Maintenance ...........................
  • Page 13: General Information, Safety Instructions, Liability Disclaimer, Area Of Use

    Area of use The magnetic filters are ideally suited for use in drinking water systems. The maximum inlet pressure is 16 bar. The outlet pressure can be set between 1.5 and 6 bar according to your own assessment.
  • Page 14: Data & Dimensions

    ENGLISH RFF24P/RFF24 Data & dimensions | Domestic water station RFF24P Length in mm DN25 DN32 Data and dimensions | Backwash filter RFF24 Length in mm DN25 DN32 www.magnetic-online.de...
  • Page 15: Installation

    ENGLISH RFF24P/RFF24 The right installation Instructions › The filter can be installed in both horizontal and vertical pipelines. › Plan for the installation of two stop cocks. › Make sure that the filter is easily accessible so that the pressure gauge and the contamination level of the filter cup are visible.
  • Page 16: Commissioning

    ENGLISH RFF24P/RFF24 Commissioning Outlet pressure adjustment › Close the stop cock in front of the filter inlet. › Reduce the pressure on the outlet side (e.g. by withdrawing water). › Close the stop cock on the outlet side. › Loosen the screw on the controller with a screwdriver (do not remove it completely).
  • Page 17: Backwashing

    ENGLISH RFF24P/RFF24 Backwashing › Ensure an inlet pressure of at least 1.5 bar. › Backwashing is only possible with the water outlet fitted. › Recommendation: Perform a backwash once a month. › If the rinsing water is not recirculated, place a collection container under the filter.
  • Page 18: Maintenance

    ENGLISH RFF24P/RFF24 Maintenance Pressure reducer › Time interval: 1 to 3 years. › Close the stop cock on the inlet side. › Release the pressure on the outlet side. › Close the stop cock on the outlet. › (1) Press a flat-blade screwdriver into the side recesses of the cap.
  • Page 19: Filter

    ENGLISH RFF24P/RFF24 Maintenance Filter › Time interval: every 2 months. › Carry out the backwash regularly (see page 17). Failure to carry out the backwash process can cause filter blockage. This results in a drop in pressure and a decreasing water flow.
  • Page 20: Faults And Troubleshooting

    ENGLISH RFF24P/RFF24 Faults and troubleshooting Domestic water station (RRF24P) Fault Troubleshooting No water pressure or pres- Check that the stop cocks installed upstream and downstream of the filter are fully open. sure too low Check whether the filter screen is visibly soiled. If existent, backwash the filter as described on page 17.
  • Page 21: Exploded Diagram

    ENGLISH RFF24P/RFF24 Exploded diagram Pos. Description Adjustment handle Spring cover Sliding ring Spring (pressure regulator) Valve core Sealing disc Nozzle edge Sieve Pressure gauge Upper housing Groove ring Guiding piece O-ring Impeller Filter unit Spring (filter unit) Filter bowl incl. backwash regulator Lower housing incl.
  • Page 22 DEUTSCH/ENGLISH RFF24P/RFF24 Datum Date Rückspülung Backwashing Sonstiges Other www.magnetic-online.de...
  • Page 23 DEUTSCH/ENGLISH RFF24P/RFF24 Datum Date Rückspülung Backwashing Sonstiges Other www.magnetic-online.de...
  • Page 24 GmbH & Co. KG Am Richtbach 5 74547 Untermünkheim Deutschland Tel. +49 7944 94199-0 Fax +49 7944 94199-19 E-Mail: info@magnetic-online.de www.magnetic-online.de...

This manual is also suitable for:

Rff24

Table of Contents