Saurya ATEXOR SLAM Hornet Neos 1LED Instructions For Safe Use

Hide thumbs Also See for ATEXOR SLAM Hornet Neos 1LED:

Advertisement

Quick Links

(Certification N:o CML 22 ATEX 3188X & IECEx CML 22.0026X)
Thank you for choosing SLAM
light for your job site. Purpose of this manual is to provide you all the necessary safety and
product information to conduct your job conveniently and without any risks for health and
(Certification N:o CML 22 ATEX 3188X & IECEx CML 22.0026X)
Contents
Instructions for Safe Use .....................................................................................................................................1
1.
1.1 Technical data ...........................................................................................................................................4
1.2 Certification of equipment ..........................................................................................................................5
1.3 Standard unit construction .........................................................................................................................6
1.4
Quality guaranteed ..............................................................................................................................8
1.4.1 General ...............................................................................................................................................8
1.4.2 Individual testing reports .....................................................................................................................8

Instructions for Safe Use

®
Hornet Neos or SLAM FIXED
®
®
safety.
®
Novo .........................................................................3
Atexor Oy Seinäjoki • P.O.Box 89 • FIN-60101 Seinäjoki • FINLAND
www.a texor.co m • Tel: +3 58 20 734 3250 • Trade Reg. No. 486 .515 • VAT No. FI08 37082 3
9.11.2022
Novo -portable or fixed work

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ATEXOR SLAM Hornet Neos 1LED and is the answer not in the manual?

Questions and answers

Summary of Contents for Saurya ATEXOR SLAM Hornet Neos 1LED

  • Page 1: Table Of Contents

    9.11.2022 Instructions for Safe Use (Certification N:o CML 22 ATEX 3188X & IECEx CML 22.0026X) Thank you for choosing SLAM ® Hornet Neos or SLAM FIXED ® Novo –portable or fixed work light for your job site. Purpose of this manual is to provide you all the necessary safety and product information to conduct your job conveniently and without any risks for health and safety.
  • Page 2 2/26 Prior to use ..............................9 2.1 Selection of right equipment ........................9 2.1.1 Intended purpose of equipment ......................9 2.1.2 Application of use (Zone XX) in accordance with equipment category ..........9 2.1.3 Explosion group (IIA, IIB or IIC) in accordance with Equipment group (IIA, IIB or IIC) ......9 2.1.4 Temperature class of the equipment....................
  • Page 3: Introduction To Slam ® Hornet Neos Or Slam Fixed ® Novo

    3/26 Introduction to SLAM Hornet Neos or SLAM ® FIXED Novo ® (Certification N:o CML 22 ATEX 3188X & IECEx CML 22.0026X) This instruction manual guides you through the process of selecting and adopting SLAM ® ® Hornet Neos or FIXED Novo work light at your work site.
  • Page 4: Technical Data

    4/26 1.1 Technical data ® SLAM Hornet Neos 1LED ® SLAM Hornet Neos 2LED ® SLAM Hornet Neos Linear 2LED SLAM Hornet Neos EM 1LED ® SLAM FIXED Novo 1LED A ® SLAM FIXED Novo 2LED A ® SLAM FIXED Novo 1LED B (throughwired) ®...
  • Page 5: Certification Of Equipment

    5/26 1.2 Certification of equipment The SLAM ® Hornet Neos or SLAM FIXED ® Novo–series has been designed, tested and certified for portable or fixed use. There is “X” –mark in the certificate for special conditions of safe use of the equipment. Special conditions of safe use specifies: ...
  • Page 6: Standard Unit Construction

    6/26 specific hazardous athmosphetic mixture). This definition is analogues to the term “intrinsically safe” applied to electrical circuits IIC = Equipment group (including explosion hazardous areas of IIA, IIB and IIC gases) T4 = Maximum inside temperature of the unit is 135 °C (within the ambient temperature range -40°C - +55°C) Gb = Explosion Protection Level (EPL) marking for “HIGH”...
  • Page 7 7/26 the unit tough and durable in severe conditions. Moreover, the frame derives excessive heat out from the luminary thereby extending lifetime of the unit. Electronic control gear: The control gear in controlling the supply of energy to the light source of the luminaire.The contol gears are independent from each others.
  • Page 8: Quality Guaranteed

    8/26 1.4 Quality guaranteed 1.4.1 General ® ® The SLAM Hornet Neos or SLAM FIXED Novo series is designed, certified, manufactured and tested under ISO 9001:2008 quality system as well as additional requirements of the ® ® Directive 2014/34/EU (ATEX) or IECEx scheme. The SLAM Hornet Neos or SLAM FIXED Novo series is designed and tested according to the latest directives and standards.
  • Page 9: Prior To Use

    9/26 Prior to use 2.1 Selection of right equipment You need to be sure that the equipment you intend to take into explosion-hazardous area matches up with the zone classification and other safety requirements related. The operator is solely responsible for the correct selection and use of the equipment at his site. At least the following points should be notified prior to use: 2.1.1 Intended purpose of equipment Please keep in mind what the actual application of equipment is.
  • Page 10: Temperature Class Of The Equipment

    10/26 This information is vital because the substances require different amount of energy to be ignited. Safety requirements for equipment are not the same for different substances (e.g. static electricity requirements).Therefore making the selection easier the gases are divided to three different groups (IIA, IIB and IIC).
  • Page 11 11/26 Selection and use of equipment is always under the responsibility of the operator. Please note that all of the aforementioned criteria are to be fulfilled when selecting the equipment. Please do not take any unnecessary risks!
  • Page 12: Operating Instructions

    12/26 Operating instructions 3.1 Personnel The use of the equipment is to be controlled and accepted by the operator. The personnel using the unit have to be authorized by the operator or his representative. In case of further training of using the equipment please contact the local supplier of this equipment. 3.2 Storage of the Neos EM Neos EM units should be stored in normal operating temperatures -20°C…+40°C.
  • Page 13: Connection To The Supply

    13/26 plastic parts or equipped with plastic covers in order to avoid electrostatic charging and a consequent risk of explosion. This process can only be done by manufacturer because the certification of the product. Please inform us about your requirement for 2-pole use when placing the order. Products originally manufactured for 3-pole use can not be modified later for 2-pole use by the operator.
  • Page 14: Electrical Installation And Connections For Throughwired Luminaries

    14/26 3.6.2 Electrical installation and connections for throughwired luminaries 1. Open connection box cover by unscrewing four torx T20 screws. 2. Install the cable throught the cable gland. 3. Select the desired phase (L1, L2 tai L3). 4. Strip connection wires for 12mm length. Connect the phase wire to the terminal block to the selected phase, which is going to be used for supplying the luminaire or luminaire chain.
  • Page 15: Adding Accessories To Slam® Hornet Neos Or Slam Fixed® Novo

    15/26 3.7 Adding accessories to SLAM® Hornet Neos or SLAM FIXED® Novo Atexor provides a number of different accessories but in case you afterwards want to add ® ® accessories of your own for the SLAM Hornet Neos or SLAM FIXED Novo –unit, please note the following points: 1.
  • Page 16: Pole Installation For Slam Fixed ® Novo

    16/26 3.7.3 Pole installation for SLAM FIXED Novo ® In pole fixing, the bracket can be installed above (fixing 70908, pictures 4 and 5) or below (fixing 70908_1, pictures 6 and 7) the pole centerline. Install the luminary to the fixing brackets 3. and tighten with the screw 6 on those brackets. Install the fixing brackets 2.
  • Page 17 17/26 Picture 6. Pole fixing bracket 70908_1 Picture 7. Pole fixing bracket 70908_1 installed below the pole centerline In case you do not want to do your own risk assessment for the accessories please view the whole range of accessories at http://www.atexor.com...
  • Page 18: Linking In Series

    18/26 3.8 Linking in series Certain SLAM ® Hornet Neos units may be equipped with ATX or Ceag Ex –certified socket in the factory. Sockets are considered as one option so they are added to the unit upon customer’s special request. In-built sockets are recommended when the illuminated area is notably large, complex or not enough wiring points are available.
  • Page 19 19/26 Table 2, Special conditions for CEAG sockets (apply only in +55°C and +54°C ambient for CEAG) Ambient Number of Supply voltage Cable length temperature Type of luminary luminaries in (°C) series SHN-1LED (25VA) SHN-1LED (21VA) SHN-1LED (21VA) SHN-1LED (21VA) SHN-1LED (25VA) SHN-1LED (21VA) SHN-1LED (21VA)
  • Page 20 20/26 Table 4, Special conditions for ATX & CEAG sockets Ambient Supply voltage Cable length Number of luminaries in series temperature Type of luminary (°C) CEAG Socket ATX Socket SHNL-2LED (50VA) SHNL-2LED (42VA) 55 - 53 SHNL-2LED (42VA) SHNL-2LED (42VA) SHNL-2LED (50VA) SHNL-2LED (42VA) SHNL-2LED (42VA)
  • Page 21: Special Operating Features Of Neos Em

    21/26 3.10 Special operating features of Neos EM Connect luminaire to the mains/transformer. Push the power button on the end part to turn the luminaire on and off. Power button has an integrated standby/power LED to ease finding the button at dark enviroments and indicating that the luminaire is powered. All EM -units are equipped with Li-Ion battery backup to allow the LED module to illuminate at up to 15% of the normal light output during power failures.
  • Page 22: Inspection & Maintenance

    22/26 4.Inspection & Maintenance 4.1 After use ® Take the following steps after the SLAM®Hornet Neos or SLAM FIXED Novo –unit has been taken out from Ex –area: 1) Clean the unit with a damp cloth (do not use detergents or solvents) 2) Change the anti-static film if only little light comes through it or it is damaged 3) Have a visual check on the unit (condition of cable, PC –tube, tightness of parts) 4) Let the unit dry in open air...
  • Page 23: Testing

    23/26 4.3 Testing Tests are to be done according to EN/IEC 60079-19 until returning the repaired unit back to operation. Below mentioned tests shall be done in addition to the tests specified in EN/IEC 60079-19. For acceptance criteria please refer to the original test report of the equipment which is included in the delivery ...
  • Page 24 24/26 This page intentionally left blank...
  • Page 25 25/26 This page intentionally left blank...
  • Page 26: Helpdesk

    Under any doubt or question, please contact your local distributor or the manufacturer. Contact details: Phone: +358 20 734 3250 Distributed by: Saurya HSE Pvt Ltd HO: C-112A Kailash Business Park, Fax: +358 20 734 3299 Veer Sawarkar Marg, Vikhroli West, Mumbai 400079, India T: +91 22 4065 5555 | E: info@sauryahse.com | W: sauryahse.com...

Table of Contents