HESCH HE 5410 Operating Instructions Manual

Differential pressure transmitter

Advertisement

Quick Links

HE 5410
Differential pressure transmitter
Operating instructions
(Original German version)
#341494

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HE 5410 and is the answer not in the manual?

Questions and answers

Summary of Contents for HESCH HE 5410

  • Page 1 HE 5410 Differential pressure transmitter Operating instructions (Original German version) #341494...
  • Page 2: Legal Notice

    AXXERON HESCH electronics GmbH, documentation department Copyrights © Copyright 2025 AXXERON HESCH electronics GmbH. All rights reserved. The content including pictures and the design of these operating instructions are subject to copyright protection and other laws for the protection of intellectual property. The operating instructions may only be distributed as a complete document and only with reference to the source.
  • Page 3: Table Of Contents

    TECHNICAL DATA ............................7 ..........................7 EVICE IDENTIFICATION MOUNTING .............................. 8 ELECTRICAL COMMISSIONING ........................9 ............................10 ONNECTIONS ..........................10 ONNECTION SCHEME INDICATION AND OPERATING ELEMENTS ....................11 MAINTENANCE AND SERVICE ......................... 12 HE 5410 Operating instructions #341494 | Version 2.0...
  • Page 4: Legal Provisions

    Legal provisions Manufacturer AXXERON HESCH electronics GmbH, Boschstraße 8, 31535 NEUSTADT, GERMANY Intended use The differential pressure transmitter HE 5410 is suitable for a 10…36 V DC  connection.  The device can be operated within the operating and environmental conditions approved in these operating instructions without impairing its safety.
  • Page 5: Safety Information

    Indicates a potentially hazardous medium risk situation, which, if not avoided, could result in death or serious injury. CAUTION! Indicates a hazardous low risk situation, which, if not avoided, could result in minor or moderate injury. HE 5410 Operating instructions #341494 | Version 2.0...
  • Page 6: Afety In The Individual Operating Phases

    Secure the device against being unintentionally switched If the device is linked to other devices and/or equipment, consider the impacts and take appropriate precautions before switching it off. Abbreviation for Deutsche Gesetzliche Unfallversicherung (German Social Accident Insurance) HE 5410 Operating instructions #341494 | Version 2.0...
  • Page 7: Technical Data

    KWF according to DIN 40040 ( ≤ 75 % rel. humidity, no Climatic application class: condensation) -20 °C…+55 °C Ambient temperature for operation: Subject to technical changes! Device identification Name plate exemplary with 0…25 mbar HE 5410 Operating instructions #341494 | Version 2.0...
  • Page 8: Mounting

    Do not connect any other loads to the terminals. This may distort the measuring current (see also Figure 3)! Scope of delivery  HE 5410 differential pressure transmitter  Operating instructions Note! Check the delivery upon receipt for completeness and visible defects. In the event of a complaint, contact your responsible representative at AXXERON HESCH electronics GmbH immediately.
  • Page 9: Electrical Commissioning

    The temperature limitations specified for the use of the device must be complied with before and during operation. Note! Do not connect any other loads to the terminals. This may distort the measuring current (see also Figure 3)! HE 5410 Operating instructions #341494 | Version 2.0...
  • Page 10: Connections

    No other loads may be connected to The higher pressure (+) is applied the terminals in order not to distort to the front connection! the measuring current! Connections (pneumatical and electrical) Connection scheme Mains Measuring input Connection scheme HE 5410 Operating instructions #341494 | Version 2.0...
  • Page 11: Indication And Operating Elements

    In case the zero point must be set for some reason, please observe the 30 minute warmup time of the device and contact the service of AXXERON HESCH electronics GmbH, if necessary (see chapter 7 Maintenance and Service).
  • Page 12: Maintenance And Service

    Dispatch metals and plastics for recycling. Electrical and electronic components must be collected separately and disposed of properly. Dispose of assembled printed circuit boards properly. Service AXXERON HESCH electronics GmbH Boschstraße 8 31535 NEUSTADT GERMANY Phone: +49 5032 9535-0 Internet: www.hesch-automation.com Email: info@hesch.de HE 5410 Operating instructions #341494 | Version 2.0...

Table of Contents