  • Page 1 T R miniBTE T R Compatible with: Alpha XT miniRITE T R and miniBTE T R Alpha XT miniRITE T R and miniBTE T R Alpha miniRITE T R and miniBTE T R Alpha miniRITE T R and miniBTE T R...
  • Page 3 Introduction to this booklet This booklet guides you on how to use and maintain your new charger. Ensure you read this booklet carefully, including the Warnings section. This will help you get the most benefit from your charger. Warnings Text marked with a warning symbol must be read before using the device. If you have additional questions about the use of your charger, contact your hearing care professional.
  • Page 4: Intended Use

    Intended use Intended use The charger is intended to recharge the hearing aids and CROS transmitter that contain rechargeable batteries. The product is intended to be used together with the given hearing solution. Indications for use There are no indications for use (diagnoses) for the charger itself.
  • Page 5: Table Of Contents

    Table of contents About Charger Temperature conditions Getting started Prepare charger Charge the hearing aids Charging time Daily use Power the charger using other sources Caring for your charger Warnings General warnings More info Troubleshooting Conditions of use Compliance statements Warranty...
  • Page 6: Charger

    Charger What it is and does USB cable Insert in power plug or Charging ports other power sources For hearing aids when charging Power plug LED light For power socket Status indicator for Power cable (varies from charger ON/OFF Supply power country to country) About Getting started...
  • Page 7: Temperature Conditions

    Temperature conditions Temperature Charging condition Below +5°C No charging due to low temperature (+41°F) +10°C to +35°C Best charging condition. Charging takes up to 3.5 hours. (+50°F to +95°F) +5°C to +10°C and Extended charging. Charging takes up to 5 hours. +35°C to +40°C (+41°F to 50°F and +95°F to +104°F)
  • Page 8: Prepare Charger

    Prepare charger Connect to power source Charger is turned ON 1. Insert the USB plug into the power When the charger is connected to plug. power, the GREEN LED turns ON. 2. Insert the power plug into a power socket. The charger turns ON automatically.
  • Page 9: Charge The Hearing Aids

    Charge the hearing aids Place hearing aids in charger Charging Place the hearing aids in the The hearing aid LED lights turn ON charging ports as shown in the when the hearing aids are correctly picture. Make sure that the hearing placed in the charger.
  • Page 10: Charging Time

    Charging time Ensure you fully charge your hearing aid before first time use. Charge your hearing aid every night. That ensures you start your day with fully charged hearing aid. Be aware that charging time may vary depending on the remaining capacity of the battery and between the left / right side hearing aid.
  • Page 11 If your hearing aid’s battery is completely drained the normal charging time is: miniRITE T R Fully charged 50% charged 25% charged 3 hours 1 hour 0.5 hours miniBTE T R Fully charged 40% charged 20% charged 3.5 hours 1 hour 0.5 hours When the battery is fully charged, the charging process stops automatically.
  • Page 12: Power The Charger Using Other Sources

    Power the charger using other sources You can power the charger from other sources than a power socket. This can be done by using the charger’s USB cable. Ensure that the power source is USB 2.0 compliant, with a minimum of 500mA output.
  • Page 13: Caring For Your Charger

    Caring for your charger Always ensure that the charger is dry and clean before use. Keep the charging ports clean from dust by using a dry cloth. Do not use water or cleaning fluids to clean the charging ports. Store your charger in a dry location, e.g. in the bedroom. Ensure you keep the charger in an environment with a temperature between +5°C and +40°C (+41°F and +104°F).
  • Page 14: General Warnings

    General warnings For your personal safety and to ensure Choking hazards of swallowing small correct usage, you should familiarize parts yourself fully with the following general Keep all small parts (for example, hearing warnings before using your charger. aids, earpieces, batteries, etc.) out of reach Consult your hearing care professional if and sight of children and others who might you experience unexpected operations or...
  • Page 15 Connection to external equipment The safety of the charger, when connected to external equipment with USB cable, is determined by the external signal source. When the charger is connected to external equipment which is plugged into a power socket, this equipment must comply with IEC 62368-1 or equivalent safety standards.
  • Page 16: Troubleshooting

    Troubleshooting Symptom Possible causes The charger LED remains turned OFF when the The charger is not turned ON charger is connected to power The charger LED shows The hearing aid or charger’s temperature is too warm long ORANGE blinks The charger’s temperature is too cold The charger LED repeatedly shows three short ORANGE blinks...
  • Page 17 Solutions Verify that the power plug is correctly connected Ensure that the power source delivers sufficient output for your charger, a minimum of 500mA. Move the charger and hearing aid to a location with a temperature between +5°C and +40°C (+41°F and +104°F) Move the charger to a location with a temperature between +5°C and +40°C (+41°F and +104°F) Contact your hearing care professional...
  • Page 18 Troubleshooting Symptom Possible causes The hearing aid LED blinks GREEN when Hearing aid has not been in use for an extended period of time hearing aid is placed in the charger The charger is not turned ON The hearing aid or charger’s temperature is either too warm or too The hearing aid LED cold remains turned OFF...
  • Page 19 Solutions Depending on how depleted the battery in the hearing aid is, the hearing aid automatically resumes normal charging mode after a timeframe of up to 10 minutes Ensure you leave the hearing aid in the charger during this process Verify that the charger power plug is correctly connected Move the charger and hearing aid to a location with a temperature between +5°C and +40°C (+41°F and +104°F) Reinsert the hearing aid into the charger.
  • Page 20: Conditions Of Use

    Conditions of use Operating conditions Temperature: +5°C to +40°C (+41°F to +104°F) Humidity: 5% to 93%, non-condensing Atmospheric pressure: 700 hPa to 1060 hPa Transportation and Temperature and humidity shall not exceed the below storage conditions limits for extended periods during transportation and storage: Temperature: -25°C to +70°C (-13°F to +158°F) Humidity: 5% to 93%, non-condensing...
  • Page 21: Compliance Statements

    Compliance statements Radiofrequency radiation exposure information For body-worn operation, this device meets Innovation, Science and Economic Development (ISED) Canada’s RF exposure limits and has been tested while in contact with the human body. Use of other accessories not verified by the manufacturer may not ensure compliance with ISED Canada’s RF exposure guidelines.
  • Page 22 Declaration of Conformity is available at the Medical Device Regulation (EU) the headquarters. 2017/745. The device is classified as CISPR 11 Bernafon group 2 class B equipment. This means Kongebakken 9 that the device is using locally generated DK-2765 Smørum...
  • Page 23 Imported and Distributed by Audmet Canada Ltd 1600-4950 Yonge St Toronto, ON M2N 6K1...
  • Page 24 Description of symbols accompanying the product Warnings Text marked with a warning symbol must be read before using the device. Manufacturer The device is produced by the manufacturer whose name and address are stated next to the symbol. Indicates the medical device manufacturer, as defined in EU Regulations 2017/745.
  • Page 25 Description of symbols accompanying the product Serial number Indicates the manufacturer’s serial number so that a specific medical device can be identified. Medical Device The device is a medical device. Nature of supply voltage Indicates that the nature of the device’s power supply voltage shall be DC (direct current).
  • Page 26: International Warranty

    International warranty Your device is covered by an you have bought your device. Your international warranty issued by the hearing care professional may also have manufacturer. This international issued a warranty that goes beyond the warranty covers manufacturing clauses of this international warranty. and material defects in the device Please consult him/her for further itself, but not in accessories such as...
  • Page 27: Warranty

    Warranty Certificate Name of owner: _______________________________________________________ Hearing care professional: _______________________________________________ Hearing care professional’s address: _______________________________________ Hearing care professional’s phone: ________________________________________ Purchase date: ________________________________________________________ Warranty period: _______________ Month: ________________________________ Model: _______________________ Serial no.: ______________________________...