Caution: Indicates a potentially hazardous situation which, if not avoided, can result in minor personal injury or equipment damage. Note: Information that may assist in completing a task correctly or for maintaining the machine in good operating condition. CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Caution: Do not paint over or remove unit nameplates, labels, or tags. Caution: Use of any dry acid or chemicals other than the CCH® Dry Acid Plus designed for use with this feeder shall void this warranty and NSF certification.
Water sprays the bottom of the basket through three 90° full cone nozzles. CCH® Dry Acid Plus dissolves and creates a 93% sodium bisulfate solution. 10 lbs of sodium bisulfate is equivalent to 1 gallon of muriatic acid.
2 .2 Process Flow Diagram Figure 1. CCH® Acid Plus feeder with CCH® Elite feeder installation CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
100 - 240V AC / 15 – 20 Amps dedicated outlet – 60 Hz Single phase only (for installing the 1HP booster pump without a CCH® Elite feeder) – 50 Hz systems require locally sourced booster pump (see booster pump section for more info) Determine the inlet and outlet location of the booster pump and venturi loop.
Are all CCH® Acid Plus components on hand? Is all essential equipment supplied by others on hand? Are all COTS tools and other equipment on hand? Is all PPE on hand? CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
11. Complete the 1 ½” piping run from the outlet of the venturi to the outlet nipple on the pool return using as few 90° elbows as practicable. The use of 45° elbows in place of 90° elbows are preferred to minimize backpressure on the venturi outlet. CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Complete assembly on the booster pump discharge prior to the venturi If installing with the CCH® Elite feeder, install the ½” nipple and threaded Tee at the discharge of the booster pump, otherwise skip this step and go to step 1b Install the ½”...
Refer to the schematic in Figure 1 and booster pump and venturi assembly (Figure 4 and Figure 5) for guidance If installing the CCH® Acid Plus dry acid feeder with CCH® Elite chlorine feeders, a dual venturi configuration is required for optimal performance.
If using with a CCH® Elite feeder, is the control box cover closed and screws securely tightened? If the booster pump is wired to a CCH® Elite control box, is dip switch 4 set to the off position for Always On...
When filling the hopper with sodium bisulfate acid, use a scoop dedicated for this purpose. Use a dedicated scooper to add CCH® Dry Acid Plus into the hopper on top of the meshed grid. Plug the solenoid valve power supply into the pH control output of the chemical controller Close hopper lid.
Ensure the booster pump is powered on at the facility breaker if using with a chlorine feeder OTHER than a CCH® Elite. Ensure the CCH® Elite control box is powered on and in ORP mode if the booster pump is wired directly into the control box.
Debris on the DV float or arm can interfere with feeder discharge operation. Remove debris as needed. CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Remove the venturi via the 1 ½” unions and visually inspect and verify it is not clogged with scale build up. If scale buildup is found, refer to cleaning instructions in the CCH® Elite Manual, Section 8.2. Inspect solenoid During feed or wash cycle, if solenoid valves are hot to the touch, consider rebuilding or replacing...
Remove and clear debris from check valve Blocked or clogged venturi Remove and inspect venturi. Clear any debris from suction port. If using with a CCH® Elite feeder, clean if necessary. Refer to CCH® Elite cleaning instructions, section 8.2. Shut inlet valve...
Approximately 220 lbs. [100 kg] Operating Temperature 40°F – 130°F [4.4ºC – 54.4ºC] Feeder Dimensions 17” L x 17” W x 34” H [43.2 cm x 43.2 cm x 86.4 cm] Solenoid Cable 72” [1.8 m] CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
(For guidance only, see notes) Note: The main function of the CCH® Dry Acid Plus is to neutralize the pH increase effects of. 10 lbs of cal hypo needs approximately 1.2 lbs of sodium bisulfate to keep the pH balanced. Consequently, total acid use is dependent on chlorine demand in lieu of physical pool size.
Granular screen assembly 887180 Hinge rod, PVC 0.25 x 5.5L (comes 205477 with set screw) Set screw for hinge rod, Hex 5/16-18 x 0.5L Chemical hopper 887137 Solution base 887138 CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
205450 only Emergency shut off float plate 71539 Rubber gasket for emergency shut 205540 off valve Emergency Shut Off Float Plate PVC 205453 Emergency shut off overflow float 205454 CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Threaded check valve 4721K13 205959 Connector male ½” P8MC8 71890 DV body 206080 DV arm 206079 DV float 79810 Silicone washer, 1.5 OD x ¾” ID x ⅛” 71576 thk (not pictured) CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
(not shown) Solenoid valve, 24 VDC Granzow 73114 Transformer with DIN/LED, 6′ DIN 73113 cord Interchangeable plug for N. America/ 73140 Japan (not shown) CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Limited Warranty The CCH® Acid Plus Feeder is warranted against any manufacturing defects in material or workmanship for a period of 12 months after installation or 18 months after shipping from Solenis, whichever is earlier. This warranty applies only to the original end-user.
Page 29
This page intentionally left blank CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Page 30
This page intentionally left blank CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Page 31
This page intentionally left blank CCH® Acid Plus System Operation and Installation Manual (Model CCH-1AP) Rev 2.1 08/2024...
Need help?
Do you have a question about the CCH-1AP and is the answer not in the manual?
Questions and answers