Do you have a question about the DS5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Celestica DS5000

  • Page 1 DS5000 Installation Guide DS5000 Installation Guide...
  • Page 2: Table Of Contents

    ......................1 1 DS5000 DS5000 ....................................................2 2 Pr Preface eface ....................................................3 3 DS5000 System Ov DS5000 System Over erview view ....................................4 4 Hardwar dware Ov e Over erview view ..........................................7 7 F F an Remo an Remov v al al ........................
  • Page 3: Re Revision Hist Vision Histor Ory

    Revision Hist vision Histor ory y This section lists the summary of changes corresponding to each release. Release Release Date Date Change Summar Change Summary y 1.0.0 8/2024 New document 1.1.0 12/2024 Added Revision History 1.2.0 4/2025 Added Ground Lug Assembly (GLA) installation instructions...
  • Page 4: Ds5000

    Disclaimer Copyright © 2025 by Celestica. All Rights Reserved. "Celestica" refers to Celestica Inc. and its subsidiaries. For additional information, please visit our website at www.Celestica.com. All trademarks, trade names, service marks, and logos mentioned belong to their respective owners.
  • Page 5: Pr Preface Eface

    Pr Preface eface Document Scope This document provides a detailed overview of the DS5000 data center switch's design features and offers guidance on its use. Intended Audiences ▪ System architects ▪ Firmware engineers ▪ System application engineers Document Conventions The following table describes various types of notes used within this installation guide.
  • Page 6: Ds5000 System Ov Ds5000 System Over Erview View

    DS5000 System Ov DS5000 System Over erview view The DS5000 offers high availability and performance in a 2U, 800G data center switch form factor. Part of Celestica's family of 800G switches, it stands out for its unparalleled density and performance.
  • Page 7 Regulatory - Safety: UL, CB, CCC The DS5000 is a prominent member of the Celestica 800G switch series, noted for its high density and suitability for sophisticated networks. Up to 16-ports of 30W optics can be supported on the top four leftmost (1,5,9,13) and four rightmost (49,53,57,61) and bottom four leftmost (4,8,12,16) and four rightmost (52,56,60,64) ports.
  • Page 8 Figur Figure 3. e 3. DS5000 Side View DS5000 Side View DS5000 Rear Side View...
  • Page 9: Har Hardwar Dware Ov E Over Erview View

    Field Replaceable Units (FRUs) The DS5000 is designed with redundancy and availability in mind. DS5000 comes with 2+1 redundant fans and 2+2 redundant, hot swappable 2000W PSUs. The following sections cover the removal and installation of these field replaceable units.
  • Page 10: F F An Remo An Remov V Al

    F F an Remo an Remov v al al Pr Procedur ocedure e 1 1 Press silver tab to the left to release the fan tray from the chassis. 2 2 Use handle to pull straight back and remove the fan.
  • Page 11 3 3 Example of Fan module when removed. 4 4 Reverse the steps to reinstall.
  • Page 12: Psu

    CAUTION: UTION: For products with multiple power cords, all power cords must be disconnected   to completely remove power from the system. Not all power cords have the same current ratings. Do not use the power cord CAUTION: UTION: ...
  • Page 13 2 2 Use handle to pull PSU straight out of chassis.
  • Page 14 3 3 Example of PSU when removed. 4 4 Reverse the steps to reinstall.
  • Page 15: Gr Ground L Ound Lug Installation Ug Installation

    Context Context The ground lug assembly (GLA) is used to safely and effectively ground the DS5000's chassis to the rack in which it is installed. This is an important task in the overall installation process of the data center switch.
  • Page 16 2 2 Verify the part numbers as listed within image.
  • Page 17 CAUTION: UTION: The image shows the ground lug assembly and the grounding wire   terminal. The terminal must have a #10 AWG wire (not shown) crimped within it. The other end of the grounding wire must be securely attached to an unpainted metal surface on the rack.
  • Page 18 4 4 Remove both nuts and washers from grounding bracket.
  • Page 19 5 5 Attach the grounding wire terminal and reinstall the washers and nuts.
  • Page 20 6 6 Tighten both nuts to 4.5 inch/pounds (+/- 0.5 in/lb).
  • Page 21 7 7 The GLA installation process is complete.
  • Page 22 8 8 When crimping the 10AWG cable to the lug, remove 0.38" of shielding to expose the metal wire. Slide it into the lug and ensure metal-to-metal contact before crimping. The terminal must have a #10 AWG wire (not shown) crimped within it. CAUTION: UTION: ...
  • Page 23: Chassis Installation

    Chassis Installation Chassis Installation DS5000 is designed to be installed in a standard 19'' four post rack. The bracket kit is only for 19 inch (483mm) wide, with a depth ranging from 22 inches ~ 33.5 inches (558mm ~ 850mm) as measured from rack post to rack post.
  • Page 24: Pr Pre-Installation Information E-Installation Information

    To prevent the rack from tipping during equipment installation, the anti-tilt bar CAUTION: UTION:   on the rack must be deployed. If a standard 19'' rack is not available, DS5000 can be placed on a clean, stable, and level...
  • Page 25 surface. Leave a clearance of 100mm (~4 inches) around the chassis for ventilation. Do not place anything on top of the chassis.
  • Page 26: Unbo Unboxing Xing

    Unbo Unboxing xing Pr Procedur ocedure e 1 1 Unpack the accessory rail kit box. Ensure there is no damage and no parts are missing. 2 2 Identify the front and rear of all four rail components.
  • Page 27: Installation T Installation Tools Ools

    Installation T Installation Tools ools It is recommended to gather the following tools before starting the chassis installation. ▪ Phillips Head (PH#1 and PH#2) slotted screwdrivers ▪ Standard flat blade screwdriver ▪ Anti-static wrist strap ▪ Anti-static overalls ▪ Protective gloves...
  • Page 28: A A Ttaching The Chassis Br Ttaching The Chassis Brack Acket Et

    A A ttaching the Chassis Br ttaching the Chassis Brack acket et Context Context Pr Procedur ocedure e 1 1 Separate the inner and outer brackets. a a Fully extend rail. b b Move white tab to release the two halves of the rail. 2 2 If not installed, attach the M4 standoff screws provided in the accessory kit to both sides of chassis.
  • Page 29 (detail 3) fit in rack square holes. Then, lock them with M6 screws (PH#3 slotted screwdriver). 7 7 Ensure there is adequate clearance around the switch to maintain proper air circulation. 8 8 Repeat for opposite side. 9 9 You have completed installing the DS5000.
  • Page 31: A A Ttaching The Rail T Ttaching The Rail To The Rack O The Rack

    A A ttaching the Rail t ttaching the Rail to the Rack o the Rack Pr Procedur ocedure e 1 1 Pull back the latch on the front of the rail and guide the standoffs into the rack holes. Release the latch to hold it in place. 2 2 Pull back the latch on the rear side of the rails and push the standoffs through the back rack holes.
  • Page 32 3 3 Insert and tighten the set screw to complete installation.
  • Page 33 4 4 Repeat for opposite side.
  • Page 34: Installing Chassis Int Installing Chassis Into Rack O Rack

    Installing Chassis int Installing Chassis into Rack o Rack Pr Procedur ocedure e 1 1 Fully extend the rails from the rack to their locked position. 2 2 Align and insert the chassis onto the rails. Simultaneously slide the blue tabs on each side towards the rack to release the latches and push it all the way into the rack.
  • Page 35: Saf Safety Pr Ety Precautions Ecautions

    Read this section before beginning any procedure. For your safety and the proper maintenance and operation of the DS5000, please follow these precautions when setting up this device. ▪ Follow all cautions and instructions marked on the equipment. ▪ Ensure the voltage and frequency of your power source match the voltage and frequency noted on the system's electrical rating label.
  • Page 36: P P Ower Ower

    P P ower ower Depending on the type of power system your device has, the following symbols may be used. On - On - Connects power to the system. This can be AC or DC power depending on product and model. Off - Off - Disconnects power to the system.
  • Page 37: Power Connection

    NOTE:   This symbol is used when multiple power supplies are installed in a system. This warning label is typically found on the back of the device near the PSU. Power Connection Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians.
  • Page 38: Regulat Regulator Ory Information Y Information

    Any modifications made to this device that are not approved by Celestica may void NOTE:  ...
  • Page 39 In accordance with European Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), the presence of the above symbol on the product or on its packaging indicates that this item must not be disposed of in the normal unsorted municipal waste stream. Instead, it is the user's responsibility to dispose of this product by returning it to a collection point designated for the recycling of electrical and electronic equipment waste.
  • Page 40: Contact Information

    Customers can register and request support (as well as search information in the knowledge base) at: https://customersupport.celestica.com/csm In case there are any questions or issues using the customer portal visit: https://www.celestica.com/contact-us. For immediate questions, please feel free to call your responsible account manager.