TempTron 616 User's Manual TEMPTRON 616 OPERATION MANUAL __________________________________________________ Functions 01. Time (not shown on front panel menu) ______________________________ 4 02. Required Temperature ___________________________________________ 4 _________________________________ Stir Fan Error! Bookmark not defined. 03. Stir Fan On ___________________________ Error! Bookmark not defined.
Page 3
TempTron 616 User's Manual ________________________________________________________ Alarm 32. Alarm Low set _________________________________________________ 9 33. Alarm High set ________________________________________________ 10 34. Alarm Type __________________________________________________ 10 35. Alarm Disable ________________________________________________ 10 ________________________________________________ Light program 36. Index ________________________________________________________ 11 37 Light Start ____________________________________________________ 11 38.
Page 4
TempTron 616 User's Manual 87. Op Mode _____________________________________________________ 16 88. Min Fan Off __________________________________________________ 16 89. Heat Sink ____________________________________________________ 16 90. Protocol _____________________________________________________ 16 91. Version Number _______________________________________________ 16 ____________________________________________ Flap Calibration ______________________________________ TROUBLE-SHOOTING ________________________________________ DEFAUT SETTINGS ________________________________________________ Installation info@agrologic.com...
TempTron 616 User's Manual Functions 01. Time (not shown on front panel menu) This is a reading of the current time setting. It is possible here to adjust the time reading. 02. Required Temperature The required temperature is the required temperature in the house. All set points (except the cool temperature set point) are set as a differential above or below the required room temperature.
TempTron 616 User's Manual o 20. Minimum Air Per on page 7, function 21. Minimum Air Per Kg Low on page 8 and function 22. on page 8. o The minimum ventilation is running in a cycle mode as calculated using the fan air capacity (function Error! Reference source not found.
TempTron 616 User's Manual 05. Fan 2 Fan 2 set point is the temperature differential above the requested room temperature that fan 2 will turn on. When fan group 2 comes into operation the inlet will open to its preset opening as set in function 12. Flap Position 2 % on page 6.
TempTron 616 User's Manual 11. Flap Position 1 % Enter here the percentage that the inlet will open each time the corresponding fan group comes into operation. Example; Fan group 1 = Position 1= 10% Flap 1 Position % default: 11 12.
TempTron 616 User's Manual 13. Flap Position 3 % Enter here the percentage that the inlet will open each time the corresponding fan group comes into operation. Fan group 3 = Position 3 Flap 3 Position % default: 33 14. Flap Position 4 % Enter here the percentage that the inlet will open each time the corresponding fan group comes into operation.
TempTron 616 User's Manual 20. Minimum Air Per Hr Enter here the total amount of cubic air per hour that minimum ventilation fan groups can supply. Take the total amount and divide it by 1000. Example: If fan group 1 can supply 20,000 cubic meters of air per minute then enter the value 20.
TempTron 616 User's Manual Cooling System The cooling system will operate in a cycle mode once the average house temperature reaches the set temperature in function 27, Cool Temperature (see below). The cycle will use the On and Off times as set in functions 35 and 36 (on page 4).
TempTron 616 User's Manual Example: Required temperature 25.0 Alarm High: 5.0 If the house temperature rises to 30.0 then the alarm relay will be activated. Alarm High default: 10.0° 34. Alarm Type Shown here is the current alarm displayed as a number. Each number represents a different alarm (see alarm list below).
TempTron 616 User's Manual 38. Light Stop Enter here the light stop time for the chosen program. 39. Trolley Start Enter here the Trolley start time for the chosen program. 40. Trolley Run Enter here the Trolley run time for the chosen program.
TempTron 616 User's Manual 44. Minimum Temperature Minimum temperature recorded over the last 24 hours. 45. Minimum Temperature Time Time that the minimum temperature occurred in the house. 46. Maximum Temperature Maximum temperature recorded over the last 24 hours. 47. Maximum Temperature Time Time that the maximum temperature occurred in the house.
TempTron 616 User's Manual Table Temperature Reduction It is possible to set an automatic temperature reduction table for the Required house temperature. 56. Day 1 Temp Day 1 temperature is the required temperature for the first grow day. It is the temperature that will appear as required temperature (function 02) when 1 is entered in function 76.
TempTron 616 User's Manual Each time day one is entered at Grow Day, the Current Weight will be updated to this weight Important: When Day is equal to 1 it is not possible to change current weight. Weight increase table 67-75.
Number of sensors for average. Enter here up to 4 sensors to be used for calculating the average temperature. 85. Net Name It is possible to connect the Temptron 616 to a PC computer with the help of the "WebChick" software package. Each unit needs an individual net name. 86. Digital input Reading This is a display of the current digital input in use.
Page 18
TempTron 616 User's Manual 87. Op Mode Enter here 0 if the feed is being measured by digital input. Enter 1 if the feed is being measured by pulse. 88. Min Fan Off Enter here the fan groups that will be turned off when Tunnel On Group is passed.
TempTron 616 User's Manual Flap Calibration Flap 1 Calibration (inlet) It will be necessary to calibrate the inlets / curtains before the start of each flock. A. Go to the time function (code 01) B. Push on “PROG” C. Enter “4441” and press "Enter".
Page 20
TempTron 616 User's Manual DEFAUT SETTINGS Function name Page number _______________________________ Required Temperature default: 25.0° _____________________ Stir Fan On default: 30 Error! Bookmark not defined. _____________________ Stir Fan Off default: 30 Error! Bookmark not defined. ___________________________________________ Heat 1 default: 1.0°...
Page 21
TempTron 616 User's Manual __________________________________ Cool Temperature default: 32.0° _____________________________________ Cool On Time default: 01:00 ____________________________________ Cool Off Time default: 05:00 ________________________________ Cool Humidify Set Point default: 90 _______________________________________ Alarm Low default: 10.0° _____________________________________ Alarm High default: 10.0° _____________ Light Maximum Setting default: 90 Error! Bookmark not defined.
Need help?
Do you have a question about the TempTron 616 and is the answer not in the manual?
Questions and answers