Summary of Contents for Photonic Universe DC1212-90 Series
Page 1
90A 12V DC to DC Battery Charger DC1212-90 series INSTRUCTION MANUAL...
Page 2
Overview This powerful 90A Photonic Universe DC-DC battery charger is fully automatic and ideal for leisure vehicles, commercial and special purpose vehicles, boats, and any other systems with multiple batteries or power sources. The charger operates using an adjustable three-stage charging programme and is suitable for lead acid, AGM, GEL, LiFePO4 and Lithium-ion (NCM) batteries.
Page 3
Reference Description Source battery positive input (+) Common negative (-) Target battery positive output (+) Green terminals Remote meter port DIP switches LED display Bluetooth dongle port Cooling fans Installation Install the battery charger as close to the target (OUT) battery as possible and keep the surrounding area clean, tidy, and well ventilated.
Page 4
Note: DIP switch 2 sets the trigger method to start the charger: • If the trigger is set to D+ signal, the charger will require a D+ signal to operate. If there is no signal applied to the D+ terminal, the charger will not turn on. •...
Page 5
temperatures vary substantially from the baseline temperature of 25°C. The sensor performs two main functions: • Charging voltage adjustment. The charging voltage for the target battery is compensated up or down depending on the ambient temperature to regulate the speed of chemical reaction inside the battery. The voltage will increase in the winter and decrease in the summer at the rate of 18mV for each degree Celsius away from the reference temperature 25°C.
Page 6
• And the source battery (IN) is the vehicle’s starter battery • And DIP switch 2 of the charger is set to “D+” signal (please refer to the DIP switches section for more information). In such case, the charger will only operate at times when the alternator sends a “D+” signal to this “D+”...
Page 7
DIP switches DIP switch 1: select the charging power. DIP switch position Description 1: ON The charger runs at half the rated current. 1: OFF The charger runs at full rated current. DIP switch 2: select the trigger method to start charging. DIP switch position Description Voltage control mode: there is no need to connect “D+”...
Page 8
DIP switches 4, 5, and 6: battery selection. The battery type for the target battery can be selected using DIP switches 4, 5 and 6. This setting will determine the charging parameters used for charging the target battery, such as charging voltage and temperature compensation.
Page 9
Note: the battery type should not be changed whilst the charger is powered. If the battery type needs to be changed, first power off the charger, then change the DIP switch configuration, then turn the charger on again. Note: any lithium battery used with this charger must have a Battery Management System (BMS).
Page 10
Slow flashing Target battery voltage is normal (1 flash / 5 seconds) Fast flashing Target battery over-voltage, high voltage Target (1 flash / 1 second) disconnect (HVD) Target battery low-voltage, low voltage disconnect (LVD) Source (starter) battery charging In addition to charging the target battery, in certain conditions the charger can also trickle charge the source (starter) battery with the current up to 5A to maintain its level and ensure it’s ready to start the vehicle: Trickle charge from...
Page 11
Equalisation: for selected battery types, the charger will perform equalisation charging by timer once a month with a higher charging voltage, in order to bring all battery cells to the same level. Equalisation charging will last for 2 hours. Please refer to the battery types table for more information.
Page 12
Battery type parameters High Voltage Low Voltage Constant Battery type Boost Float Equalisation Disconnect Disconnect voltage (HVD) (LVD) charging time 14.3V 13.8V 15.5V Sealed 14.4V 13.5V 14.6V 15.5V Flooded / 14.7V 13.5V 14.8V 15.5V LiFePO4 13.9V 13.8V 15.5V (13.9V) LiFePO4 14.2V 13.8V 15.5V...
Page 13
< 12.05V > 12.45V < 11.90V Stop charging > 13.20V Specifications Parameter Value Target battery Gel, Sealed, AGM rated voltage LiFePO4 rated voltage 12.8V Lithium-ion (NCM) rated voltage 11.1V Recommended battery capacity 120-800Ah Battery operating voltage range 8V-16V Source battery Rated battery voltage Recommended battery capacity 60-100Ah...
Page 14
Optional surface mounted (CB series) and recess mounted (CBR series) DC circuit breakers can be purchased from Photonic Universe and used instead of fuses when connecting this charger to the source and target batteries. The range of circuit breakers includes 30A – 250A surface mounted, and 40A –...
Page 15
Bluetooth dongle ACDC-BT (optional) Using an optional Bluetooth dongle ACDC-BT, this charger can be connected to a smartphone app to allow the user to monitor charging parameters such as real time battery voltage, charging current, charging Ah, charging Wh and any fault information. To setup the Bluetooth dongle and connection to the smartphone, please install the correct and up-to-date version of the app using the name, links or QR codes for the app provided in a separate user manual for the Bluetooth dongle.
Need help?
Do you have a question about the DC1212-90 Series and is the answer not in the manual?