Instruction manual - EN Contents 1. Intended use 2. Technical specifications View of instrument plate for boilers with exhaust fan, ATMOS AC32 electronic controller for automatic wood ignition (AIW) Advantages of boilers 3. Technical data Boiler drawings key Technical data...
Page 4
In non-compliance with these instructions the drum’s and the heatproof pipes’ service life may dramatically decrease. The boiler drum may corrode in as little time as 2 years. CAUTION - INSTALLER SHOULD ALWAYS COMPLY WITH LOCAL PLANNING AND BUILDING REQUIREMENTS. www.atmos.eu 4-EN...
Instruction manual - EN 1. Intended use The environmentally friendly boilers ATMOS DC32S and DC40SX are designed for heating family houses, cottages, holiday houses and other similar buildings. Boilers are suitable for buildings with heat loss ranging between 15 - 40 kW, depending on type. The boilers are constructed mainly for burning logs.
When the switch is set to 0, the function is switched off. 9. AC32 electronic controller - the use of the rotary knob allows you to set the time (delay) or temperature of the accumulation tank at which the automatic wood ignition (AIW) will occur.
The blanking chamber /5/ must be inserted into the boiler instead of the ignition cham- ber /3/, whenever we do not use automatic wood ignition. This protects the ignition spiral and the ignition chamber against unnecessary wear (the service life is extended). www.atmos.eu 10-EN...
5. Boiler accessories Steel brush with accessories 1 pc Poker 1 pc Filling-in valve 1 pc Operating and maintenance instructions manual 1 pc Draught regulator - HONEYWELL FR 124 1 pc Removable blanking chamber and pellet filling scoop (with pocket) 1 pc www.atmos.eu EN-11...
3450 14400 INFO - Raw wood does not burn easily, produces a lot of smoke and substantially decreases the service life of your boiler and chimney. Boiler output drops as low as 50 % and fuel consumption doubles. www.atmos.eu 12-EN...
3 - Boiler CAUTION - No other devices may be installed in the boiler room if they could create vacuum at the boiler installation site. Maximum permissible vacuum in the boiler room (boiler installation site) is 0 Pa. www.atmos.eu EN-13...
ČSN 061008. These are appropriate for mobile installations, wooden cottages etc. 1 - Flue gas thermometer 2 - Cleaning aperture 3 - Throttle valve (draught limiter) INFO - In case of excessive chimney draught, install draught regulator (limiter) /3/ or a throttle valve. www.atmos.eu 14-EN...
PVC etc.) the boilers must be put out of operation long enough before the risk occurrence. No items from flammable materials may be placed on the boilers or near them for a distance lower than the specified safe distance (more see ČSN EN 13501-1). www.atmos.eu EN-15...
1 - connector for income cabel (L - brown, N - blue, PE - green/yellow) 2 - connector for pump in boiler circuit - white (L - brown, N - blue, PE - green/yellow) 3 - connector for exhaust fan DCxxS(X) Pocket for thermostats (sensors) Capacitator for exhaust fan UCJ4C52 - 1μF www.atmos.eu 16-EN...
ČSN EN ISO 11202:2010, ČSN EN ISO 3746:2011, ČSN EN 15036-1:2007 CAUTION – the boiler must be installed in compliance with a design prepared in advance. Installation may only be carried out by persons trained by the manufacturer. www.atmos.eu 18-EN...
When installing the boiler, position the rear section 10 mm higher in order to facilitate circulating and air-bleeding. For the heating system regulation we recommend regulation elements provided by the following companies: ATMOS ACD 03 / 04 - Equithermal controller set for solid fuel boilers www.atmos.eu EN-19...
65 °C for water returning to boiler. Another variant is connection of the boiler with a three-way mixing valve with an actuator controlled from the electronic controler (e.g., ATMOS ACD 03 (ACD 04)) to keep minimum temperature of the water returning to the boiler (65 - 75 °C).
If need be, a thermoregulatory valve set to a higher temperature (E.g. 72 °C) may be used. Recommended sizes of the thermoregulatory valve TV 60 °C (65/70/72/77 °C) For boilers: DC32S, DC40SX............... DN32 www.atmos.eu EN-23...
50 - 150 Volume (l) 2000 - 3000 1000 - 1500 1500 - 2000 3000 - 6000 The standard ATMOS accumulation tanks provided TANK TYPE VOLUME ( l ) DIAMETER ( mm ) HEIGHT ( mm ) AN 500 1970...
They can only be operated by adults. INFO - Boilers with automatic fuel ignition enable both classic manual ignition and automatic planned ignition of wood using the integrated ignition device (ignition chamber and ignition spiral). www.atmos.eu EN-25...
Remove the screw lid of the ignition device. Remove the ignition or blanking chamber and clean the space above the ignition spiral plate properly. Example of removing the ignition or blanking Example of cleaning the space above the chamber ignition spiral plate www.atmos.eu 26-EN...
Page 27
Screwing in and tightening the automatic chamber ignition lid CAUTION - For ignition device we use only high-quality pellets of Ø 6 - 8 mm and the length of 10 - 5 mm and the calorific value of 16 - 19 MJ/kg www.atmos.eu EN-27...
Page 28
Insert small kindling chips on the newspaper in the same way as the first layer was laid, i.e. (across the logs with the paper). Filling the space between the logs with Inserting kindling chips across the chamber newsprint paper above newsprint paper www.atmos.eu 28-EN...
Page 29
(80 – 90 °C), see page Closed ignition valve - retracted pulling rod Open (set) valve for combustion air supply to the boiler (set on 80 - 90 °C) www.atmos.eu EN-29...
Tightened locking screw of the stoking door Setting and starting the automatic wood ignition - ATMOS AC32 Controller The ATMOS AC32 electronic controller is designed for a simple setting and control of the automatic wood ignition. The use of the rotary knob...
Page 31
INFO - In case of repeating process of the automatic wood ignition (new START), always switch the switch to position O for at least 2 seconds and then to the desired position I or II. www.atmos.eu EN-31...
Page 32
INFO - The accumulation tank temperature sensor (TV (AIW) (NTC 20 kΩ)) is pulled out through a grommet from the boiler side hood. The sensor conductors (TV and GND) are connected to the connector together with the I-O-II switch www.atmos.eu 32-EN...
Page 33
LED indicator on the boiler panel will flash 3 times briefly. INFO - The AC32 controller is equipped with a battery, thanks to which the controller “re- members” the actions already performed, even in the event of a power failure. If the battery is discharged, the controller alerts you to replace it (after activating the function) with two short flashes.
The outgoing water temperature should be monitored on the thermometer /18/ situated on the control panel. There is also an irreversible safety thermostat on the panel. www.atmos.eu 34-EN...
Basic setting of secondary air: Optimum setting: Fully closed (0 mm) + maximum (completly pulled out) Minimum setting: Fully closed (0 mm) + 5 mm The regulation is carried out by either pulling out (+) or retracting (-) the regulating pulling rod. www.atmos.eu EN-35...
Even if the boiler operates in the slow-burn mode, it has to keep the output water temperature ranging between 80 - 90 °C and returning water minimum temperature 65 °C. www.atmos.eu 36-EN...
The slot of the combustion nozzle to the ash Always remove the decelerator when cleaning chamber must never be blocked! and removing the ash. decelerator only DC40SX) www.atmos.eu EN-37...
Page 38
Sample cleaning of impeller and checking Checking and cleaning regulation of primary- uprightness of vane on extract ventilator secondary air ratio via cleaning lid Example of cleaning the space above the Example of cleaning the ignition chamber ignition spiral plate www.atmos.eu 38-EN...
In general, always use protective equipment. The applicable fire regulations must be observed when handling fuel and ash. In accordance with legislation in force, there must be a suitable fire extinguisher provided within the reach. www.atmos.eu EN-39...
After the heating season is over, clean the boiler thoroughly and replace damaged parts. Do not leave parts replacement for the last moment; prepare your boiler for the heating season as early as Spring. www.atmos.eu 40-EN...
- replace - defective electric cord defective fibreglass cord - replace - adjust the door hinges - the nozzle becomes clogged - do not burn small-particle wood, Doors leaking sawdust, bark - chimney defect - insufficient chimney draught www.atmos.eu EN-41...
Page 42
- check – replace - defective ignition spiral - check – replace - defective AC32 controller - check – replace INFO - In case of failure, check the device and correct the defect. If you are unable to remove the failure, contact the company that installed or commissioned the product (service).
By following these steps in reverse order, you can replace the door. The door lock consists of a lever with a handle and a cam which engages a wheel that is screwed into the boiler and secured by a nut preventing its turning. www.atmos.eu 44-EN...
Instruction manual - EN 34. Environmental protection The ATMOS gasifying boilers comply with the most demanding environmental requirements and were awarded the “Environmentally friendly product” mark, in compliance with directive No. 13/2002 of the Ministry of Environment of the Czech Republic. The boilers are certified in compliance with the European standard EN 303-5 and they fall within class 4 and 5 and comply with EU Regulation 2015/1189.
- company representing ATMOS in the particular country for the particular region - installation company that carried out the installation - Jaroslav Cankař a syn ATMOS, Velenského 487, 294 21 Bělá pod Bezdězem, Czech Republic, Telephone. +420 326 701 404 www.atmos.eu...
Date Date Date Date stamp and signature stamp and signature stamp and signature stamp and signature INFO - Once a year check (review) the technical condition of the boiler room (boiler, chimney, flue duct, control, fittings, etc.). www.atmos.eu 48-EN...
Repair: ..............................Repair: ............................................repair carried out by, date Repair: ..............................Repair: ..............................Repair: ..............................Repair: ............................................repair carried out by, date Repair: ..............................Repair: ..............................Repair: ..............................Repair: ............................................repair carried out by, date www.atmos.eu EN-49...
Page 50
Kotle teplovodní s ruční dodávkou paliva na dřevo / Hot-water boilers for wood with manual fuel supply Název nebo ochranná známka dodavatele: Supplier‘s name or trademark: ATMOS Jaroslav Cankař a syn ATMOS Značka modelu Třída energetické Jmenovitý tepelný Index energetické...
Need help?
Do you have a question about the AC32 and is the answer not in the manual?
Questions and answers