16
15
14
204.8
M
8.06
L
204.8
8.06
K
INPUT CORD
LENGTH SEE
IDENTIFICATION
TABLE
J
H
G
TECHNICAL SPECIFICATIONS
UNIT TYPE:
F
ORIENTATION:
OUTLET QTY & TYPE:
(19)C13/C15, (19)C13/C15/C19
INPUT VOLTAGE:
INPUT CURRENT:
BREAKER QTY & TYPE:
(9) 20AMP, DOUBLE-POLE ,10KA
E
INPUT PHASE:
THREE-PHASE (DELTA)
RATED POWER:
INPUT PLUG:
INPUT POWER CORD:
SEE IDENTIFICATION TABLE
D
FEATURES
VOLTAGE(V), CURRENT(A), APPARENT
METERING
POWER(kVA), REAL POWER(kW),
ATTRIBUTES
POWER FACTOR, ENERGY(kWh)
C
METERED COMPONENTS
REMOTE OUTLET SWITCHING
ENVIRONMENTAL CONDITIONS
OPERATING TEMPERATURE
-5 TO 60 C (23 TO 140 F)
STORAGE TEMPERATURE
-20 TO 60 C (-4 TO 140 F)
B
HUMIDITY
5-90% RH / 5-95% RH;
(OPERATING/STORAGE)
MAX OPERATING
ELEVATION, ABOVE MSL
COMPLIANCE
SAFETY & ENVIRONMENTAL
A
16
15
14
13
12
11
(2)PL 24.0
.94
(2)PL 24.0
.94
SEE SHEET 2 FOR ADDITIONAL LAYOUT DETAILS
IDENTIFICATION TABLE
INPUT METERED
MODEL IS SHOWN IN DEFAULT CONFIGURATION. FOR
VERTICAL, 0U
OPTIONAL CONFIGURATIONS, USE ITEM IDENTIFIER
CODE IN PLACE OF EACH ASTERISK. ORDERABLE
BASED ON FORMAT: EN19HA - * * * *
200-240VAC
100A (80A DERATED)
OPTIONS LISTED ON THIS ROW ARE NON STANDARD,
CONTACT SALES FOR ADDITIONAL INFORMATION
28.8kVA(NAM)
NOTES:
SEE NOTE 7
1.
INSTALLATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE
AND LOCAL CODES.
2.
PRIMARY DIMENSIONS ARE IN MILLIMETERS. SECONDARY DIMENSIONS
ARE IN [INCHES]
3.
UNIVERSAL MOUNTING BRACKET IS AN ALTERNATIVE MOUNTING
METHOD TO THE TOOLLESS MOUNT FOR 3RD PARTY ENCLOSURES.
BRACKET IS PROVIDED WITH THE UNIT.
4.
DETAILED INSTALLATION INSTRUCTIONS CAN BE FOUND IN THE QUICK
START GUIDE
INPUT(PHASE)
5.
CONNECT EXTERNAL EARTH GROUND TO THE 10-32 SIZE THREADED NUT
6.
SEE PRODUCT DOCUMENTATION FOR FURTHER INFORMATION
NO
7.
INPUT PLUG CONFIGURATION (SEE IDENTIFICATION TABLE) FOR DUAL-
RATED UNITS, NEMA PLUGS ARE NAM RATED ONLY AND CAPTIVE AUS/NZ
PLUGS ARE EMEA RATED ONLY
NON-CONDENSING
3000M (9840 FT)
THIS DRAWING AND SPECIFICATIONS HEREIN ARE THE PROPERTY OF CIS
GLOBAL AND SHALL NOT BE COPIED, REPRODUCED OR USED IN WHOLE OR IN
PART, AS THE BASIS FOR THE MANUFACTURE OR SALE OF ITEMS WITHOUT
RoHS COMPLIANT
WRITTEN PERMISSION FROM CIS GLOBAL. THIS DRAWING IS BASED UPON
LATEST AVAILABLE INFORMATION AND IS SUBJECT TO CHANGE WITHOUT NOTICE
13
12
11
10
9
8
7
1555.0
61.22
REAR VIEW
1555.0
61.22
SIDE VIEW
1980.0
77.95
NMC SHOWN IN DEFAULT ORIENTATION
FRONT VIEW
*
EN19HA -
INPUT PLUG
(DEFAULT) 4100P9W(IP67) = 0
ECN/ECO
TITLE:
PROJECT:
10
9
8
7
6
5
4
TOOLLESS MOUNTING
BUTTON LOCATIONS(12)PL
*
*
CHASSIS COLOR
CORD OPTION
(DEFAULT) 1.8m [6'] = 0
(DEFAULT) BLACK = 0
BLUE = B
1m [3.2'] = 1
RED = R
WHITE = W
2m [6.6'] = 2
GREEN = G
YELLOW = Y
3m [10'] = 3
0.5m [1.6'] = A
ORANGE = A
1.5m [4.9'] = B
2.5m [8.2'] = C
3.5m[11.4'] = D
E1
INITIAL DRAFT REVIEW
REV.
DESCRIPTION
REVISIONS
UNLESS NOTED, DIMENSIONS ARE IN
MILLIMETERS & TOLERANCES ARE:
X.
1
MM
ADVANTAGE SERIES
X.X
0.5 MM
INPUT METERED
X.XX
0.20 MM
X.X
0.3 MM
X.XX
0.10 MM
BRACKETED DIMENSIONS ARE IN
en
INCHES FOR REFERENCE ONLY
LOGIC
THRID ANGLE PROJECTION
INTERPRET PER ASME Y14.5M-1994
6
5
4
3
2
1
(2)PL
18.4
M
.72
K
(4)PL 48.0
1.89
H
75.0
2.95
56.0
2.20
G
BOTTOM VIEW
*
ORIENTATION
(DEFAULT) TOP FEED = 0
BOTTOM FEED = 2
4.5m[14.7'] = E
1.2m [4'] = G
E
3.65m[12'] = H
4m[13.2'] = 4
D
C
2024/03/20
ZLF
DATE
APPROVED
PART NO:
REV.
E1
B
EN19HA-WXYZ_DA
X
1
DRAWN BY:
ZLF
2024/03/20
X.X
0.5
ENGINEER:
LJB
2024/03/20
APPROVED BY:
Hanson
2024/03/20
SIZE:
SCALE: N/A
SHEET
A3
A
1 OF 3
3
2
1
L
J
F