INSTRUCTION MANUAL
Téléchargez la version Française ici.
Download de Nederlandse versie hier.
Laden Sie die deutsche Version hier herunter.
SPECIFICATIONS
Power
80W or 150W
Display
US 120V / EURO-UK
Tip to Ground
Input Voltage
230V
Impedance
100-500°C
Tip to Ground Voltage
Temp. Range
(212-932°F)
Cable Length
Temp. Stability
±2°C > 200°C
Weight
Temp. Compensation
±50°C (±90°F)
WARNING
This product is classified as an electrical appliance and must be used in accordance
with safety measures to prevent accidents.
Connecting the soldering station incorrectly poses a risk of injury and damage to the
device. Risk of burns from the soldering tool while the soldering station is operating.
The product is tested before despatch, so the tip may contain a small amount of tin
and the tube may have a slight yellowish tinge, this is normal.
• Read the safety instructions and operating instructions all the way through and
observe the specified precautionary measures before operating the soldering station.
• Always place the soldering iron in the safety holder when not in use.
• The tip can reach a high temperature of +150°C in a short time. Be careful to avoid
burns.
• If you are under the age of 18, you must use this product under the supervision of
professionals or an informed adult.
• This appliance is not intended for use by persons (including children) with reduced
physical sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety
• Observing locally applicable accident prevention regulations.
• Do not use the soldering station around combustibles
• Do not use or operate this product with wet hands or in damp environments to
prevent electric shock.
• Do not modify this product and accessories.
• Observing locally applicable accident prevention regulations.
• When replacing parts or soldering tips, ensure the power is turned off and wait for
the device to cool down completely before proceeding.
• Always turn off the iron when the product is not in use or temporarily not needed.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
1
DESCRIPTION
Flexible arms
Display
Selector knob
Brass wool
Tin hole
Sponge
Digital
*Soldering tin is sold separately
<0.1Ω
DISPLAY EXPLANATION
<2mV
120cm
Screen Display
Function
516g
Autosleep
Temp.
Calibration
Temp. Locking
Auto Standby
OPERATION
- Power ON: Connect the power cord to the mains supply, Switch on the ON/OFF
button, now the display lights up.
- Rotate the selector knob to set the desired temperature.
(For example, a temperature of 350°C is reached in about ten seconds.)
- After use, don't forget to switch it off.
FUNCTION DIAGRAM
Press and hold down
the selector knob.
Function
Operating
Menu
Mode
Selection
Press and hold down
the selector knob.
Setting save
Exit setting
Power Switch
Soldering tin
dispenser*
Soldering tip
Replaceable
Soldering Handle
Heater element
Screen Display
Function
Temp. Unit
Software Version
Power OFF
Rotate
Press the selector
Left or Right
button once.
Enter Selection
Mode
Function
Menu
Selection
Press and hold down
Rotate Left or Right
the selector knob.
2
FUNCTIONS
Auto standby/Auto sleep Function
Press and hold the knob button to enter the function settings menu.
Rotate left or right to switch until the screen displays
Press once the knob to enter function. Rotate left or right to select
Once enabling the auto standby/auto sleep mode, the machine will enter standby
status after 3 minutes of inactivity, and the display shows
ature is reduced to 250°C max. If the device remains in standby mode for a further
10 minutes, the heater will switch off. During standby period, if the unit detects any
movement, or if the adjustment knob is short-pressed, it will resume to the working
mode. Short-press the knob button in
status to return to the working mode.
Temperature mode Celsius/Fahrenheit
Press and hold the knob button to enter the function settings menu. Rotate left or right
to switch until the different screen displays
.
Short press the knob to enter the function. Rotate left or right to select Celsius
Fahrenheit
.
Temperature calibration
1. Adjust the temperature to 350°C (662°F). Wait for 1 minute to stabilize the temper-
ature. Use a temperature measuring tool to confirm the current temperature of the
heater.
2. Calculate the compensation temperature: Compensation Temperature = Selected
Temperature 350°C - Actual Measured Temperature. If the result is a positive num-
ber, increase the temperature; if it's a negative number, decrease the temperature.
Temperature compensation range: +50 to -50°C (+90 to -90°F).
3. Long press the knob button to enter the function settings menu. Rotate left or right
to switch until the screen displays
. Short press the knob to enter function selec-
tion. Rotate left or right to input temperature compensation value. Short press the
knob button to exit the function settings menu interface. Long press or short press
the knob to save the current settings and return to the heating interface.
Temperature locking
Long press the knob button to enter the function settings menu. Rotate left or right to
switch until the screen displays
. Short press the knob to enter function selection.
Rotate left or right to switch between
or
to enable or disable the temperature
lock function. *After enabling the temperature lock function, the temperature cannot be
adjusted. When rotating the adjustment knob left or right, the screen displays
Software version
Long press the knob button to enter the function settings menu.
Rotate left or right to switch until the screen displays
3
.
or
.
. The heating temper-
or
.
.
Need help?
Do you have a question about the DSS PRO 80 and is the answer not in the manual?
Questions and answers