Page 1
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow instructions to use a product exactly. The Guide is for reference only. If there is inconsistency between the Guide and the actual product, the actual product shall prevail. GUARDEON SECURITY SYSTEM...
GUARDEON SECURITY SYSTEM 72170028 Product Information FRONT REAR Night vision Display Anti-tamper button Camera Card read area Terminal 10 12 Indicator light Speaker Microphone Reset button Step 1 Step 2 Long press the RESET button Reset for 5 seconds,...
GUARDEON SECURITY SYSTEM 72170028 Wiring diagram LOCK NO POWER LOCK COM LOCK NC GATE NO Gate GATE COM INPUT 1 Door Contact INPUT 2 Exit Button 2 Wire Converter Family...
GUARDEON SECURITY SYSTEM 72170028 System wiring diagram Family 1 Family 2 Family 3 Family 4 2 Wire Converter Family 9 Family 10 DC36V, 2A Family 11 Family 12 Family 13 Family 14 Family 19 Family 20 DOOR 1 (Address 1)
GUARDEON SECURITY SYSTEM 72170028 Outdoor panel operation 1. Password setting It is recommended to change default passwords immediately and choose a strong password. Regularly change the password to your panel to help ensure that only authorized engineer are able to access the system.
GUARDEON SECURITY SYSTEM 72170028 DEVICE MANAGEMENT CONFIGURATION APARTMENT NUMBER DOOR 1 DOOR 2 CAM1 ROOM NUMBER DOOR 3 CAM2 ADD NEW DEVICES CAM3 DOOR 4 CAM4 DOOR 5 DOOR 6 CAM5 DOOR 7 CAM6 CAM7 DOOR 8 CAM8 Step 3: Click BATCH ADD PANEL TO MONITOR of outdoor panel No.1, then outdoor panels No.
GUARDEON SECURITY SYSTEM 72170028 3. Click Refresh, the IP address of the outdoor panel and indoor monitors in the same local area network will display in the list. 4. Click Config followed Apartment No. of second private outdoor panel, then input the Apartment No.
GUARDEON SECURITY SYSTEM 72170028 18/08/2022 15:12 18/08/2022 15:12 18/08/2022 15:12 SETTINGS SETTINGS LANGUAGE ENGLISH LANGUAGE ENGLISH CALL MODE CALL MODE NAME CALL NAME CALL USERS SETTINGS NAME CALL ADDRESS ADDRESS KEYPAD MASTER APARTMENT NUMBER MASTER APARTMENT NUMBER DEBUG MODE...
GUARDEON SECURITY SYSTEM 72170028 3.1.3 Verifying configuration Click DETECT AND ADD APARTMENT NUMBER, the apartment number interface is displayed. Duplicate apartment numbers are not allowed, and each apartment number cannot be the same. Click , select all apartment numbers, click , add the selected apartment number to the users list.
GUARDEON SECURITY SYSTEM 72170028 18/08/2022 15:12 18/08/2022 15:12 18/08/2022 15:12 NEW USER NAME Shelly APARTMENT NUMBER USERS SETTINGS Mar y Dolly PASSWORD DOOR Nancy Jane Barbara CARD NETWORK Tommy ENGLISH ?123 Picture 1 Picture 2 Picture 3 3.2.2 Configure related number 1.
GUARDEON SECURITY SYSTEM 72170028 4. Register SIP Click , then click SIP, input SIP ACCOUNT, PASSWORD, SERVER, click SAVE, if registered successfully, the SIP word will be shown in the upper left corner. 18/08/2022 15:12 18/08/2022 15:12 18/08/2022 15:12...
GUARDEON SECURITY SYSTEM 72170028 Calling monitor from panel 1. Calling user monitor a. After the installation and configuration is complete, click the user name to call or input apartment number, click on the outdoor panel to call the indoor monitors.
GUARDEON SECURITY SYSTEM 72170028 17:49 16-05-2020 MULTI VIDEO MONITOR CALL CAMERA Picture 1 Picture 2 Door setting The system management page is displayed. Select , and set the unlocking time and door status sensor. 18/08/2022 15:12 18/08/2022 15:12 18/08/2022 15:12...
GUARDEON SECURITY SYSTEM 72170028 Setting item Selection Note The outdoor panel does not detect if the door is open. AUDIO ALARM If the door is open after the open set time, the door station will alarm with beep sound.
GUARDEON SECURITY SYSTEM 72170028 Setting item Selection Note 1. Enter the apartment number and click to delete all user cards under this DELETE apartment number. 2. Swipe the user card directly in the swipe area and delete the user card separately.
GUARDEON SECURITY SYSTEM 72170028 Unlock operation 1. Unlock from indoor monitor During the conversation, the user clicks the LOCK to open the door, clicks the GATE to open the gate. 12-01-2021 08:00:00 CAM1 2. Password unlock A. Door Unlock: Default UNLOCK password: 123456.
GUARDEON SECURITY SYSTEM 72170028 System information Enter Settings and set the local parameters. For details, see the following table. 18/08/2022 15:12 18/08/2022 15:12 18/08/2022 15:12 SETTINGS SETTINGS LANGUAGE ENGLISH TIME SCREEN CALL MODE TIME UNTIL SCREEN STANDBY NAME CALL...
GUARDEON SECURITY SYSTEM 72170028 Setting item Selection Note Time screen saver. TIME SCREEN Turn off time screen saver. TIME UNTIL Screen saver time setting, the default time is 15S, can be SCREEN STANDBY set as 15s-4h. SPEAKER VOLUME Set the speaker volume 0-9.
GUARDEON SECURITY SYSTEM 72170028 Specifications Operation system Embedded linux operation system Display resolution 1024x600 Operation method 7" touch screen Angle of view H:125°, V:72° Video compression standard H.265 (default), H.264 Noise reduction 3D noise reduction Supplement light IR supplement...