GT-3704 Analog Input Module
4 ch RTD input, PT100/PT1000/Ni1000LG etc., 12 bit resolution, cage clamp, 10 pt removable
terminal
Doc ID: 133352
2025-02-20

Advertisement

loading
Need help?

Need help?

Do you have a question about the GT-3704 and is the answer not in the manual?

Questions and answers

Summary of Contents for Beijer Electronics GT-3704

  • Page 1 User Manual GT-3704 Analog Input Module 4 ch RTD input, PT100/PT1000/Ni1000LG etc., 12 bit resolution, cage clamp, 10 pt removable terminal Doc ID: 133352 2025-02-20...
  • Page 2 The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB reserves the right to change any information without updating this publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document.
  • Page 3: Table Of Contents

    10.1. Space Requirements ................18 10.2. Mount Module to DIN Rail ..............19 10.3. Mount Removable Terminal Block ............21 10.4. Connect Cables to Removable Terminal Block ..........22 10.5. Field Power and Data Pins ..............23 Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 5: About This Manual

    About This Manual 1. About This Manual This manual contains information on the software and hardware features of the Beijer Electronics GT-3704 Analog Input Module. It provides in-depth specifications, guidance on installation, setup, and usage of the product. 1.1. Symbols Used in This Manual This publication includes Warning, Caution, Note and Important icons where appropriate, to point out safety-related, or other important information.
  • Page 6: Safety

    Before using this product, please read this manual and other relevant manuals carefully. Pay full attention to safety instructions! In no event will Beijer Electronics be responsible or liable for damages resulting from the use of this product. The images, examples and diagrams in this manual are included for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Beijer Electronics cannot take responsibility or liability for actual use based on the examples and diagrams.
  • Page 7: About The G-Series System

    IP, EtherCAT, PROFINET, CC-Link IE Field, PROFIBUS, CANopen, DeviceNet, CC-Link, MODBUS/Serial etc. • Expansion Module - Expansion module types: Digital IO, Analog IO, and Special modules. • Messaging - The system uses two types of messaging: Service messaging and IO messaging. Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 8: Io Process Data Mapping

    Valid parameter data depends on the modules in use. For example, analog modules have settings of either 0-20 mA or 4-20 mA, and temperature modules have settings such as PT100, PT200, and PT500. The documentation for each module provides a description of the parameter data. 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 9: Specifications

    DIN rail Shock operating IEC 60068-2-27 (15G) Vibration resistance IEC 60068-2-6 (4 g) Industrial emissions EN 61000-6-4: 2019 Industrial immunity EN 61000-6-2: 2019 Installation position Vertical and horizontal Product certifications CE, FCC, UL, cUL Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 10: General Specification

    I/O cable max. 2.0 mm² (AWG 14) Weight 60 g Module size 12 mm x 99 mm x 70 mm 4.2.1. Dimensions Module dimensions (mm) 4.3. Input Specification Inputs per 4 channels module Indicators (logic 4 green input status side ) 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 11 RTD Type : ±0.1 ℃ / F , Resistance type: 1 Ω, 100 mΩ, 10 mΩ, 20 mΩ, 50 data mΩ Calibration Not required Diagnostic Sensor open or range over, then conversion data = 0x8000(-32768) Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 12: Wiring Diagram

    Wiring Diagram 5. Wiring Diagram Pin no. Signal description RTD channel 0+ RTD channel 0- RTD channel 1+ RTD channel 1- RTD channel 2+ RTD channel 2- RTD channel 3+ RTD channel 3- AGND AGND 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 13: Led Indicator

    INPUT channel 3 Green 6.1. LED Channel Status Status Indication No signal Input sensor open or input range over Normal operation Normal operation On signal Green Sensor connected and input range valid Normal operation Normal operation Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 14: Mapping Data Into The Image Table

    Analog input Ch 2 high byte Byte 6 Analog input Ch 3 low byte Byte 7 Analog input Ch 3 high byte NOTE If the input of the channel is open or over-ranged, its conversion data will be 0x8000(-32678). 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 15: Configuration Parameter - 10 Byte

    =Others: Reserved Temperature type: 00: Celsius (°C) 0: Celsius (°C) 1: Fahrenheit (°F) Reserved 02 - 03 Data resolution: 00: 0.1 ℃, ℉/bit 01: 1 ℃, ℉/bit 10: 0.01 ℃, ℉/bit * 11: Reserved Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 16 3: More enhanced filter (filter time = 80) Reserved CH0 offset value CH1 offset value CH2 offset value CH3 offset value * Data exceeding 32767 cannot be displayed. ** If fast filter is set, the specification accuracy may not be met. 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 17: Data Value

    Resistance input range Type Input range 1 Ω/bit 0 - 4000 Ω 100 mΩ/bit 0 - 2000 Ω 10 mΩ/bit 0 - 327 Ω 20 mΩ/bit 0 - 620 Ω 50 mΩ/bit 0 - 1200 Ω Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 18: Hardware Setup

    Installation position is valid vertical and horizontal. The drawings are illustrative and may be out of proportion. CAUTION NOT following the space requirements may result in damaging the product. 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 19: Mount Module To Din Rail

    • GT-5XXX • GT-7XXX GN-9XXX modules have three locking levers, one at the bottom and two on the side. For mounting instructions, refer to Mount GN-9XXX Module. Mount to DIN rail Dismount from DIN rail Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 20 10.2.2. Mount GN-9XXX Module To mount or dismount a network adapter or programmable IO module with the product name GN-9XXX, for example GN-9251 or GN-9371, see the following instructions: Mount to DIN rail Dismount from DIN rail 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 21: Mount Removable Terminal Block

    Hardware Setup 10.3. Mount Removable Terminal Block To mount or dismount a removable terminal block (RTB), see the instructions below. Mount a removable terminal block Dismount a removable terminal block Beijer Electronics, Doc ID: 133352 2025-02...
  • Page 22: Connect Cables To Removable Terminal Block

    To connect/disconnect cables to/from the removable terminal block (RTB), see the instructions below. WARNING Always use the recommended supply voltage and frequency to prevent damage to the equipment and ensure optimal performance. Connect cable Disconnect cable 2025-02 Beijer Electronics, Doc ID: 133352...
  • Page 23: Field Power And Data Pins

    Token output port of processor module Serial output Transmitter output port of processor module Serial input Receiver input port of processor module Reserved Reserved for bypass token Field GND Field ground Field VCC Field supply voltage (24 VDC) Beijer Electronics, Doc ID: 133352 2025-02...