Summary of Contents for BLAUBERG BlauCool BLHP-R-Split Series
Page 1
INSTALLATION AND OPERATION MANUAL AIR TO WATER SPLIT TYPE 12KW HEAT PUMP INDOOR UNIT (HYDRONIC MODULE) 16KW Product Implementation Standards: EN14825-2016...
blaubergventilatoren.de Dear user: Thank you for using our products! This manual is a universal version of our hydronic module for air to water heat pump unit. Although the appearance of the hydronic module you purchased may not match the appearance described in this manual, it will not affect your operation and use. Please read carefully before use and keep this manual in a safe place for your use.
AIR TO WATER SPLIT TYPE HEAT PUMP INDOOR UNIT ACCESSORIES AND LOCAL PURCHASED PARTS Accessories Installation manual Replacement Extended wire Name Wall panel Warranty card Y-type filter & energy efficiency label board & DHW tank sensor Quantity For the connection of the refrigerant system between ×...
Page 4
blaubergventilatoren.de 2. STRUCTURE OF HYDRONIC MODULE Air purge valve Electric heater Heat exchanger Expansion vessel Waterflow switch Safety valve Wired controller Water pump Water pressure gauge Gas-side pipe Water outlet Drainage exit Liquid-side pipe Water inlet This figure is only for explaining the name of each component. Please refer to the actual product for details.
Page 5
AIR TO WATER SPLIT TYPE HEAT PUMP INDOOR UNIT 3. INSTALLATION OF HYDRONIC MODULE 3.1 Space required for installation and maintenance The size of the wall panel mounted on the wall, in mm.(See Figure 3.1) 421.2 Figure 3.1 Space required for installation and maintenance, in mm. (See Figure 3.2 and 3.3) >300 >300 >300...
Page 6
blaubergventilatoren.de 3.3 Handling To avoid damage during shipping, please do not open the carton until installation. The hydronic module is heavy and requires at least two people to handle. When handling the unit, please take the protective measures. When handling the unit, please take protective measures for the surface of the unit to prevent damage to the unit panel. 3.4 Installation diagram of hydronic module Fan coil unit (Cooling/Heating)
Page 7
AIR TO WATER SPLIT TYPE HEAT PUMP INDOOR UNIT Fan coil unit (Cooling/Heating) cool water hot water Radiator unit Expansion (Heating) vessel Outdoor Unit (14, 16 kW) Water inlet Water outlet Filter Circulating Pump Motorized 2-way valve Motorized 3-way valve (SV3 status: ON) (SV4 status: OFF) Buffer tank...
Page 8
blaubergventilatoren.de Fan coil unit (Heating) cool water hot water Radiator unit Expansion (Heating) vessel Outdoor Unit (14, 16 kW) Water inlet Water outlet Filter Circulating Pump Motorized 3-way valve (SV4 status: OFF) Buffer tank Floor heating loop (Heating) Differential pressure Filter water supply valve Filter...
Page 9
AIR TO WATER SPLIT TYPE HEAT PUMP INDOOR UNIT Fan coil unit ( Cooling/Heating) cool water hot water Radiator unit Expansion (Heating) vessel Water inlet Outdoor Unit Water outlet (5, 8 kW) Filter Circulating Pump Buffer tank Floor heating loop (Heating) Differential pressure Filter...
blaubergventilatoren.de 3.5 Installation and connection of hydraulic module and terminal The hydronic module and the terminal water system are recommended to be connected in the same way (the following is a case of a fan coil, the floor heating and radiator are similar) Fan coil Fan coil Fan coil...
Page 11
AIR TO WATER SPLIT TYPE HEAT PUMP INDOOR UNIT 3.8 Water injection and antifreeze measures Water injection and air exhaust 1. The exhaust valve should be installed at the highest point of the water system piping, and the drain valve should be set at the lowest point. 2.
blaubergventilatoren.de 4. ELECTRICAL CONNECTIONS 4.1 Electrical wiring ATTENTION The hydronic module should use a dedicated power supply. The supply voltage should conform to the rated voltage. The external power supply circuit of the hydronic module must be grounded, and the ground wire of hydronic module should be reliably connected to the external ground.
AIR TO WATER SPLIT TYPE HEAT PUMP INDOOR UNIT 4.3 Circuit diagram CN32 (Reserved) PUMP Control (Reserved) T1B heat source (The black part is the dial switch) inlet temp. (Reserved) T7 water tank temp. T1 water outlet temp. DISP1 TW_out water outlet temp. TW_in water inlet temp.
blaubergventilatoren.de 5. TROUBLESHOOTING 5.1 Fault codes Water flow switch fault Communication fault between the hydronic module and outdoor T1 fault of outlet water temperature sensor Outdoor unit fault T7 fault of DHW tank water temperature sensor Tw_in fault of heat exchanger inlet water temperature sensor Tw_out fault of heat exchanger outlet water temperature Communication fault between the hydronic module and wired controller EEPROM protection...
Page 15
AIR TO WATER SPLIT TYPE HEAT PUMP INDOOR UNIT NAMES AND CONTENTS OF HAZARDOUS SUBSTANCES IN THE PRODUCT Hazardous substance Hexavalent Polybrominated Polybrominated Part name Lead Mercury Cadmium chromium biphenyl diphenyl ether (Pb) (Hg) (Cd) (Cr (VI)) (PBB) (PBDE) • • •...