Sentera Controls EME5 Mounting And Operating Instructions

Main and emergency on/off switches

Advertisement

Quick Links

EME5
MAIN AND EMERGENCY
ON/OFF SWITCHES
Mounting and operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EME5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sentera Controls EME5

  • Page 1 EME5 MAIN AND EMERGENCY ON/OFF SWITCHES Mounting and operating instructions...
  • Page 2: Table Of Contents

    INTENDED AREA OF USE TECHNICAL DATA STANDARDS SWITCHING DIAGRAMS WIRING AND CONNECTIONS MOUNTING INSTRUCTIONS IN STEPS TROUBLESHOOTING TRANSPORT AND STORAGE WARRANTY AND RESTRICTIONS MAINTENANCE MIW-EME5-EN-000 - 24 / 02 / 2025 2 - 80 www.sentera.eu back to the table of contents...
  • Page 3: Safety And Precautions

    If there are questions that are not answered, contact your technical support or consult a professional. MIW-EME5-EN-000 - 24 / 02 / 2025 3 - 80 www.sentera.eu...
  • Page 4: Product Description

    PRODUCT DESCRIPTION EME5 are surface mountable rotary isolator switches intended for commercial/ industrial applications. The switchgear is housed in a moulded enclosure with an IP65 sealing. The EME5 series includes variants providing additional contacts (NO and NC type). ARTICLE CODES...
  • Page 5: Switching Diagrams

    Output, neutral (if connected to N the circuit is not broken when the switch is in OFF position) Protective earth 13, 14 Normally open contacts 21, 22 Normally closed contacts MIW-EME5-EN-000 - 24 / 02 / 2025 5 - 80 www.sentera.eu back to the table of contents...
  • Page 6: Mounting Instructions In Steps

    MAIN AND EMERGENCY ON/ OFF SWITCHES MOUNTING INSTRUCTIONS IN STEPS Before you start mounting the EME5, read carefully “Safety and Precautions”. Then proceed with the following mounting steps: Remove and open the top of the enclosure. Remove any of the pre-stamped cable entries (knockouts) to insert the wires.
  • Page 7 The position of the switch can be signalled to the control panel / room via the NO T E additional NO and NC contacts (if available). MIW-EME5-EN-000 - 24 / 02 / 2025 7 - 80 www.sentera.eu back to the table of contents...
  • Page 8: Troubleshooting

    In case of heavy pollution, clean with a non-aggressive product. In these circumstances the unit should be disconnected from the supply. Pay attention that no fluids enter the unit. Only reconnect it to the supply when it is completely dry. MIW-EME5-EN-000 - 24 / 02 / 2025 8 - 80 www.sentera.eu...