Tecno Control AN400/I User Instructions

Gas leak detection in combustion chamber

Advertisement

Available languages

Available languages

Quick Links

I
IST-5400.AA02.01/C
File: IST-5400.AN01.01-C_AN400-I (REV-2012).docx
CONTROLLO FUGHE GAS
IN CAMERA
DI COMBUSTIONE
AN400/I
ISTRUZIONI D'USO
TECNOCONTROL S.r.l.
Via Miglioli, 47 20090 SEGRATE (MI) Italy - Tel. (+39) 02 26922890 - Fax (+39)02 2133734
http:
www.tecnocontrol.it
e-mail:
info@tecnocontrol.it

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AN400/I and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tecno Control AN400/I

  • Page 1 IST-5400.AA02.01/C File: IST-5400.AN01.01-C_AN400-I (REV-2012).docx CONTROLLO FUGHE GAS IN CAMERA DI COMBUSTIONE AN400/I ISTRUZIONI D’USO TECNOCONTROL S.r.l. Via Miglioli, 47 20090 SEGRATE (MI) Italy - Tel. (+39) 02 26922890 - Fax (+39)02 2133734 http: www.tecnocontrol.it e-mail: info@tecnocontrol.it...
  • Page 2: Table Of Contents

    IST-5400.AN01.01/C AN400/I / Istruzioni d’uso Pag. 2/12 NOTA IMPORTANTE Leggere Attentamente e Conservare questa Istruzione. Tutta la Documentazione inerente all’impianto rilevazione Gas deve essere conservata, perché contiene anche le procedure da effettuare durante le operazioni di Verifica e/o Taratura periodiche.
  • Page 3: Desrizione

    Il sensore utilizzato per rilevare il gas è un sensore Pellistor a combustione catalitica, tarato per gas Metano. Il circuito di analisi gas in camera di combustione dell'AN400/I è costituito da un filtro anticondensa a coalescenza, una pompa di aspirazione, una valvola a tre vie, un flussometro , un filtro di protezione e il sensore Pellistor per gas esplosivi.
  • Page 4: Principio Di Funzionamento

    Sull'AN400/I, sono previste due uscite a relè, una con contatti in scambio liberi da tensione corrispondente al preallarme (AL1) regolato ad una concentrazione del 10% LIE Metano e l’altra con contatto normalmente eccitato con contatti liberi da tensione per il blocco del bruciatore (AL3) quando la concentrazione supera il 30% LIE Metano, oppure se si guasta il sensore.
  • Page 5: Installazione

    6x8mm preferibilmente in acciaio inox oppure in PTFE. La distanza tra l'unità AN400/I e il punto di prelievo non dovrebbe superare i 10 metri. In camera di combustione va installato un raccordo per tubo Ø esterno 8 mm.
  • Page 6: Utilizzo Della Centrale

    0,3 l/m. Preriscaldo: quando l’AN400/I viene accceso, inizia anche la fase di preriscaldo del sensore di circa 60 secondi, dopo questo tempo il sensore è in grado di rilevare il gas, ma raggiunge le condizioni di stabilità...
  • Page 7: Sensore Ed Elettronica Di Controllo Ts292Pm - Funzionamento

    (vedi a Pag. 1 Caratteristiche Tecniche). Eseguite le verifiche spegnere e riaccendere l’AN400/I. Se la condizione persiste sarà necessario provvedere alla riparazione. Se i Led Giallo e Verde sono accesi (uscita 0mA): indica probabilmente il guasto della “Cartuccia Sensore”.
  • Page 8: Manutenzione Ordinaria

    AVVERTENZA: Non è possibile eseguire l’operazione se l’uscita in mA è superiore a 10% LIE (5,6 mA) o se è acceso il LED rosso. In questo caso contattare il nostro servizio assistenza. RICAMBI CODICE DESCRIZIONE Cartuccia Sensore Sostituibile per AN400/I (0÷100%LIE) ZSP02/EX Cartuccia a coalescenza ZF004 Filtro di protezione...
  • Page 9: Assistenza

    IST-5400.AN01.01/C AN400/I / Istruzioni d’uso Pag. 9/12 ASSISTENZA Su richiesta la TECNOCONTROL è in grado di offrire contratti di manutenzione programmata da effettuarsi annualmente o semestralmente (ad inizio e/o a metà stagione). L’intervento prevede la sostituzione delle parti di consumo se necessario, la verifica della portata della pompa, la taratura e/o la sostituzione, se necessario della “Cartuccia Sensore”...
  • Page 10: 1- Schema Cablaggio Elettrico E Analisi Gas (Piastra Di Fondo)

    IST-5400.AN01.01/C AN400/I / Istruzioni d’uso Pag. 10/12 1- Schema Cablaggio Elettrico e Analisi gas (Piastra di Fondo) ARMADIO: Vista Interna Piastra di Fondo OUT 2 OUT 2 NA NA ZS067 Alimentatore Portasensore con ZS075 PS120 a 24V Timer TI001 ZSP02 Cartuccia...
  • Page 11: Nota: Variante Cablaggio E Analisi Gas Per Pompa (Lato Destro)

    IST-5400.AN01.01/C AN400/I / Istruzioni d’uso Pag. 11/12 PIASTRADI FONDO: Foro 1(C) 2(NC) Ø2,5mm Maschiato M3 3(NA) ZF076 Elettrovalvola Mandata 3 Vie 230V Pompa EL001 Aspirazione Pompa ZF031 Pompa a Vibrazione 230V PIASTRADI FONDO: Foro Ø2,5mm Maschiato M3 NOTA: Variante Cablaggio e Analisi gas per Pompa (Lato Destro)
  • Page 12: 3-Schema Cablaggio E Analsi Gas Della Porta

    IST-5400.AN01.01/C AN400/I / Istruzioni d’uso Pag. 12/12 3-Schema Cablaggio e Analsi Gas della Porta CONTROPORTA: Vista Lato Interno ID250PM INDICATORE DIGITALE FAULT SENS. AL 2 AL 1 AL 3 + - S C NA NC C NA NC C NA NC C NA NC...
  • Page 13 IST-5400.AN01.02 .docx File: IST-5400.AN01.02_AN400-I (REV-2012-IT) EN GAS LEAK DETECTION IN COMBUSTION CHAMBER AN400/I USER INSTRUCTIONS TECNOCONTROL S.r.l. Via Miglioli, 47 20090 SEGRATE (MI) Italy- Tel. (+39) 02 26922890 - Fax (+39)02 2133734 http: www.tecnocontrol.it e-mail: info@tecnocontrol.it...
  • Page 14: Important Note

    IST-5400.AN01.02 AN400/I/ User Manual Page 2/12 IMPORTANT NOTE Please read and keep care of this manual All documentation relating to gas detection plant should be preserved, because it contains the procedures to be used during the routines verification and / or during the periodic calibration.
  • Page 15: Description

    Pellistor sensor for explosive gas. The AN400/I unit cleans the gas sensor with clean air every time the burner starts up (at the end of each analysis cycle). The cleaning process takes about 3-4 minutes and is controlled by a Timer.
  • Page 16: Operating Principle

    The sensor is enabled only when the burner is turned off and can potentially leak non-combusted gases. The AN400/I has two relay outputs. There is one pre-alarm (AL1) dry contact output configured at a concentration of 10% of the LEL of Methane and a normally energised dry contact output that disables the burner (AL3) when the concentration exceeds 30% of the LEL of Methane or when there is a fault with the sensor.
  • Page 17: Installation

    Install a pipe fitting (with an external diameter of 8 mm) in the combustion chamber. You are advised to assemble the pipe at a slight downwards angle from the AN400/I unit so that any condensate can flow back towards the combustion chamber.
  • Page 18: Using The Unit

    If necessary, set the flowmeter at about 0.3 l/m. Pre-heating: when you power the AN400/I unit, the sensor takes about 60 seconds to warm up; it is then ready to detect gas but requires 4 hours’ continuous operation to reach optimum conditions of stability.
  • Page 19: Sensor And Control Board Of The Ts292Pm - Operation

    Check that the cartridge is connected properly and compatible (refer to Page 1 Technical Characteristics). When you have done, turn the AN400/I unit off and then on again. If the problem persists, the unit may need to be repaired.
  • Page 20: Routine Maintenance

    Coalescent cartridge ZF004 ZF007 Protection filter 230VAC Vibration Pump for AN400/I PO220 3x7mm Silicone Tubing (by the metre) TU135 NOTE: The rate at which you need to replace these parts depends on extent of use of the unit, the type of fuel used, and the execution of routine maintenance.
  • Page 21: Technical Service

    IST-5400.AN01.02 AN400/I/ User Manual Page 9/12 TECHNICAL SERVICE TECNOCONTROL can, on request, offer a maintenance contract for the execution of maintenance on an annual or quarterly basis (at the start and/or half-way through the season). The contract covers the replacement, when necessary, of parts subject to wear, testing of the pump, calibration and/or replacement, when necessary, of the "Sensor Cartridge(s)", and a functional test of...
  • Page 22: 1- Wiring And Gas Analysis Diagram (Base Plate)

    IST-5400.AN01.02 AN400/I/ User Manual Page 10/12 1- Wiring and Gas Analysis Diagram (Base Plate) ARMADIO: Vista Interna Piastra di Fondo CABINET (INSIDE VIEW): BOTTOM PLATE OUT 2 OUT 2 NA NA 24VDC ZS067 Alimentatore Sensor holder with Portasensore con ZS075...
  • Page 23: Note: Wiring And Gas Analysis Version For Pump (Right Side)

    IST-5400.AN01.02 AN400/I/ User Manual Page 11/12 PIASTRADI FONDO: Foro 1(C) 2(NC) Ø2,5mm Maschiato M3 3(NA) ZF076 3Way Solenid Elettrovalvola valve 230VAC Mandata Flow 3 Vie 230V Pompa (EL001) EL001 Aspirazione Suction Pompa ZF031 Pompa a 230VAC Vibrazione 230V Vibrating pump PIASTRADI FONDO: Foro Ø2,5mm Maschiato M3...
  • Page 24: 3- Wiring And Gas Analysis Diagram Of The Door

    IST-5400.AN01.02 AN400/I/ User Manual Page 12/12 3- Wiring and Gas Analysis Diagram of the Door CABINET INNER DOOR, INTERIOR VIEW CONTROPORTA: Vista Lato Interno ID250PM INDICATORE DIGITALE FAULT SENS. AL 2 AL 1 AL 3 + - S C NA NC...

This manual is also suitable for:

An400

Table of Contents