Indicator
connection
Adjustment
Remarks
Signal source
adjustment
Level indicator
——
SE
AF-generator to
400 Hz
Fe
: ON
AF-voltmeter to
Record Level
550 mV Output
INPUT LEFT
app. 100 mV
Dolby
: ON
OUTPUT LEFT/
š
clockwise
Record Level
55 mV Output
400 Hz
app. 10 mV
VR 104
VR 104'
Adjust level indicator
to —20 dB
Oszillator, R F-trap
Frequency counter
to Point D
105 kHz
R 145'
Erasing voltage
Met
š
AF-voltmeter to
Record : ON
Point D
RF-magnetic biasing
BASF C 60
Fe
: ON
R 307
At treble emphasis:
Super LH
Record : ON
J6
connect resistor
Sony C 60
Fer
: ON
R 303
At treble de-emphasis :
FeCr Duad
Record : ON
二 学
cut off jumper
Scotch C 45
Met
; ON
R 301
Metafine
Record : ON
J8
Record level
AF-generator
400 Hz
AF-voltmeter to
Record Level
550 mV Output
to INPUT LEFT
app. 100 mV
OUTPUT LEFT/
and RIGHT
RIGHT
VR 107
VR 107'
Cr
: ON
Adjust to 550 mV
BASF C 60
Dolby
: ON
VR 108
Reverse
Chromdioxyd
Record : ON
VR 108' Reverse
BASF C 60
Fe
: ON
R 137
Super LH
Dolby
: ON
R 137'
During test recording don't
Record : ON
change RECORD LEVEL
==)
>550 mV: connect jamper
Sony C 60
FeCr
:ON
FeCr Duad
Dolby
: ON
<550 mV : cut off resistor
Record : ON
SE
Scotch C 45
Met
: ON
Metafine
Dolby
: ON
Record : ON
|
10
Need help?