These instructions are intended for qualified personnel who are 1. Notes on documentation familiar with the assembly, installation and operation of the ISYGLT system. It is essential that you read these operating instructions through before commissioning and keep them accessible for 1.1.
• supply unit Assembly and installation of the ISYGLT module may only be car- must only be connected in accordance with protection class III • ried out by a qualified electrician. Other activities in connection with...
These are limited to the intended use of the module and refer EU on waste electrical and electronic equipment at the local collec- to the repair or replacement of the ISYGLT module. Please send the tion points for waste electrical and electronic equipment! device with an attached error description to our company address given below.
• Hotel and conference room • Shopping mall and retail shop The LED dimmer can be operated with either the ISYGLT, DMX512 8/16 bit, DMX-RDM 8/16 bit or DALI protocols. The functions and options of the LED-04B-ANA-V2: • Calculation of rise times from 0.5 seconds to 12 hours •...
Page 6
• 4 connections anodes (+) Power-LED • 4 connections cathodes (-) Power-LED Parameterisation with ProgrammDesigner In the ISYGLT ProgrammDesigner there are various parameterisation options: • Channel single operation or coupling • Setting of various dimming curves • Minimum and maximum values...
Page 7
DIP switch DMX512 operation DMX operation with delay (oversampling of 8-bit to 16-bit values) Default 50ms, adjustable by parameterisation from 10ms to 1s, as well as „Soft“ DMX 8-Bit = DIP 1 = ON, DIP 2 = OFF DMX 16-Bit = DIP 1 = ON, DIP 2 = ON Switch Function Description...
DALI - + for LED channel 2 - for LED channel 2 + for LED channel 3 Subnet (BUS A, RS-485) ISYGLT or DMX - for LED channel 3 Subnet (BUS B, RS-485) ISYGLT or DMX + for LED channel 4...