You will find the exact details specified on the nameplate attached to the connecting cable. Schematic diagram: Special version WEX2… WEX3… without temperature sensor Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025 4 of 19...
ATEX glands are fully sealed. If this cannot be guaranteed, the analysis line must not be put into operation. Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone: +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025...
Include a straight section (5 x hose diameter). A large bending radius will increase the service life of the hose. Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025...
Page 7
Use a counter-wrench during installation to prevent twisting the hose. Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone: +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025 7 of 19...
Page 8
When fixing the hose with clamps or similar it must be ensured that the outer structure is not squeezed. Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025...
They can be very high and are not registered on normal pressure gauges. The operating pressure must never be exceeded. Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025...
WEX2… WEX3... 15. QM-Certificate according to ISO 9001:2015 and to Directive 2014/34/EU Certificate Annex VII Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone: +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025 17 of 19...
Page 18
Instructions for Installation and Operation ATEX heated analysis lines WEX2… WEX3... Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025 18 of 19...
Page 19
Instructions for Installation and Operation ATEX heated analysis lines WEX2… WEX3... Winkler AG ▪ Englerstrasse 24 ▪ 69126 Heidelberg ▪ Germany ▪ Phone: +49 6221 3646 0 ▪ sales@winkler.org ▪ www.winkler.org Issue 03/2025 19 of 19...