EM3405 Manual Contents Ⅰ. Introduction ......................1 Ⅱ. Technical data and functions ................1 Ⅲ. Appearance of the weather station ..............3 Part A - Positive LCD ................... 6 Part B - Function keys and connections ............6 Part C - Wireless remote sensor ................ 6 Ⅳ.
EM3405 Manual Ⅰ. Introduction Thank you for choosing the Uzoli EM3405 weather station. The EM3405 weather station consists of a base station (receiver), a remote sensor and a power adapter with USB type C connector. The following manual contains step-by-step instructions for installation, operation and setting, please read it carefully and keep it.
Page 4
EM3405 Manual Frost point alarm for outdoor 6 weather forecast symbols: sunny, partly cloudy, cloudy, rainy, stormy, snowy 5 levels of brightness for backlight (LV4 to LV1 and then off) Measuring range: - Indoor temperature: -9.9°C to 50°C, accuracy ±1°C (=2°C) - Outdoor temperature: -40°C to 70°C, accuracy ±1°C (=2°C)
EM3405 Manual Ⅳ. Installation instructions 1. Install the base station Firstly, connect the base station to the power supply using the power adapter supplied. It is recommended to equip the base station with 2 AAA batteries together with the power adapter to ensure that the base station can save its settings and function properly even in the event of a power failure.
EM3405 Manual Ⅴ. Default setting 1. The base station switches on all segments of the LCD for 3 seconds after switching on the power supply. After the beep "BI", the unit switches to standard mode and starts measuring the indoor temperature and humidity and air pressure.
Page 11
EM3405 Manual Temperature unit ( ℃ / ℉ ) → Air pressure unit (hpa/ inHg) → (12/ 24)-hour format → Hours → Minutes → Year → Month → Day → Language→ Air pressure (reference value) → Weather forecast (reference value) → Exit ...
EM3405 Manual decreases with increasing altitude, the public weather services always publish the so-called relative air pressure. If you want to match the air pressure to your location, you can ask your local weather service for the air pressure at sea level or get the current value from the Internet.
EM3405 Manual When the setting value flashes at 1 Hz, press the [▲] key briefly to add the value by 1, press and hold the [▲] key to add the value rapidly. When the setting value flashes at 1 Hz, press the [▼] key briefly to decrease the value by 1, press and hold the [▼] key to decrease the value rapidly.
EM3405 Manual In snooze mode, press any key except the [ ] key or press and hold the ] key for more than 2 seconds or do nothing within 1 minute to exit snooze mode. If the snooze function is deactivated, pressing the [ ] key will not switch to snooze mode.
EM3405 Manual 7. Temperature and humidity measurement Indoor temperature measuring range: -9.9°C (+14°F) to +50°C (+122°F), division value 0.1°C/ °F; LL.L °C/ °F is displayed when the value is below -9.9 °C (+14°F); HH.H °C/ °F is displayed when the value is above +50°C (+122°F).
EM3405 Manual : If the humidity has decreased by 5%RH in each measurement compared to the previous data or if the total humidity has decreased by 5%RH within 1 hour, the trend arrow points downwards. No trend: when switching on or when the humidity remains constant.
EM3405 Manual In alarm display mode, press the [▲] key to turn the corresponding alarm on/ off (the default is OFF). When switched on, the corresponding icon " " and " " is displayed. 11. Setting for temperature and humidity limit ...
EM3405 Manual When the outdoor temperature is within the range of -1°C (+30°F) to +3°C (+37°F), the " " icon flashes in the channel data area (but the alarm does not sound). 13. Comfort level and mold risk There are 5 display modes for the comfort level, as follows:...
EM3405 Manual The weather station displays the following 6 weather icon: Partly sunny cloudy rainy stormy snowy cloudy Note: The "snowy" icon is only displayed if the outdoor temperature is below -4°C (+5°F) and the forecast would be rainy or stormy. The outdoor temperature mentioned here is set to the temperature of CH1 by default.
EM3405 Manual 16. Low battery status If the icon " " appears on the display in the indoor area (INDOOR), you need to replace the base station battery as soon as possible. If the icon " " appears on the display in the area of channels (OUTDOOR), you need to replace the battery of the corresponding outdoor sensor as soon as possible.
Page 21
EM3405 Manual When the night mode is set to ON, in the setting mode, press the [ ] key to set the night mode. While pressing the [▲] or [▼] key, you can add or decrease the setting value. The order of setting is as follows: the brightness at night (LV1 to LV3) →...
EM3405 Manual Ⅶ. Additional information MANUFACTURER: Company Name: dongguanshiyouyidianzishangwuyouxiangongsi Address: guangdongshengdongguanshihoujiezhenjiajudadao1108shi IMPORTER: Company Name: dongguanshiyouyidianzishangwuyouxiangongsi Address: guangdongshengdongguanshihoujiezhenjiajudadao1108shi Email: uzoliweather@outlook.com Contact Person: Viola Name: Sea&Mew Consulting GmbH Address: Mittenhuber Straße 4, 92318 Neumarkt Email: Compliance.EU@outlook.com Contact Person: Yuan Li The symbol with the crossed-out wheeled bin means that the product must be disposed of separately from household waste.
Need help?
Do you have a question about the EM3405 and is the answer not in the manual?
Questions and answers