Download Print this page

Compaq 108164-003 - ProLiant - 800 White Paper page 21

Disk subsystem performance and scalability
Hide thumbs Also See for 108164-003 - ProLiant - 800:

Advertisement

ECG025.0997
W
P
HITE
APER
(cont.)
. .
. .
In Figure 10, our tests show that if you require 24 Gigabytes of storage capacity the
. .
. .
performance gain of 33% is in using twelve 2GB disks instead of six 4GB disks. With
. .
concurrency taking place by using multiple lower capacity drives (twelve 2GB drives),
. .
. .
more requests are being processed; thus improving performance. However, consider the
. .
limitations of this configuration. By having twelve lower capacity drives, you are limiting
. .
. .
the maximum disk capacity on that controller.
. .
. .
. .
. .
. .
. .
. .
. .
20,000,000
. .
. .
18,000,000
. .
. .
. .
16,000,000
. .
. .
14,000,000
. .
. .
. .
12,000,000
. .
. .
10,000,000
. .
. .
8,000,000
. .
. .
. .
6,000,000
. .
. .
4,000,000
. .
. .
. .
2,000,000
. .
. .
0
. .
4
. .
. .
. .
. .
. .
Figure 10: Like Capacity Scaling in a RAID 0 Environment.
. .
. .
Similar test results were found in our RAID 5 environment. Again, when scaling (or using
. .
more drives) in an environment, the like capacity test shows a 54% performance increase
. .
. .
when using eight 2GB drives versus four 4GB drives, as shown in Figure 11.
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
. .
21
Like Capacity Scaling (RAID 0 - 1 Controller)
8
16
20
24
28
Number of Clients
33%
32
36
40
44
48
12 x 2GB
6 x 4GB
3 x 9GB
52
56
57

Advertisement

loading