Ventless universal hood system for electric cooking appliances (44 pages)
Summary of Contents for Wells WVC46
Page 1
WELLS MANUFACTURING 265 Hobson Street, Smithville, Tennessee 37166 t e l e p h o n e : (800) 264-7827 www.wells-mfg.com OWNER'S MANUAL VENTLESS UNIVERSAL HOOD SYSTEM ELECTRIC OVENS, PROOFERS AND HOLDERS MODEL WVC46 IL2629a Manual Includes INSTALLATION USE & CARE...
Page 2
THE FOLLOWING WILL NOT BE COVERED UNDER WARRANTY. products to be free from defects in material or workmanship, under normal Wells’ sole obligation under this warranty is limited to either repair or and proper use and maintenance service as specified by Wells and upon...
C U S T O M E R S E R V IC E D A T A INTRODUCTION Thank You for purchasing this Wells Manufacturing appliance. Thank You for purchasing this Wells Manufacturing appliance. P r o p e r i n s t al l at i o n , p r o f e s s i...
FEATURES & OPERATING CONTROLS Nam eplate WVC-46 IL2631c Ventilator Section Operating Features & Controls...
Page 5
FEATURES & OPERATING CONTROLS continued FEATURES & OPERATION CONTROLS IT E M D E S C R IP T IO N C O M M E N T VENTILATOR EXHAUST DUCT, FRONT Exit point for ventilator airflow - on front of unit. DO NOT BLOCK VENTILATOR FAN Provides air movement for ventilation HI-EFFICIENCY/CHARCOAL FILTER...
PRECAUTIONS AND GENERAL INFORMATION T h i s v e n t i l a t o r h o o d i s p a r t o f a n e n g i n e e r e d s y s t a n d i s i n t e n d e d f o r u s e i n co m m e r ci a l e s t a b l i s h...
AGENCY LISTING INFORMATION T h i s a p p l i a n ce co n f o r m s t o N S F S t a n d a r d 4 f o r s a n i t a t i o n o n l y i f i n s t a l l e d i n a cco r d a n ce w i t h t h e s u p p l i e d Installation Instructions...
INSTALLATION (continued) UNDER-HOOD APPLIANCE LIMITATIONS: Ap p l i an c e m u s t b e i n s t al l e d p e r m an u f ac t u r e s i n s t r u c t i o n s . Electrical appliances only.
INSTALLATION (continued) SERVICE TECHNICIAN INSTALLATION NOTES Th i s v e n t i l at o r h o o d i s t o b e u s e d w i t h l i g h t - d u t y an d m e d i u m - d u t y electrically powered cooking appliances only.
Page 10
INSTALLATION (continued) Site Preparation 1 . P r o v i d e c l e ar an c e ar o u n d i n s t al l at i o n s i t e t o s a f e t y r i g an d l i f t equipment into its final position.
INSTALLATION (continued) MECHANICAL INSTALLATION Th e f o l l o w i n g i s a s t e p - b y - s t e p p r o c e d u r e f o r i n s t al l at i o n o f t h e Re c i r c u l at i n g H o o d s .
INSTALLATION continued DISCHARGE DIRECTION MODIFICATION The unit comes configured for a front discharge, changing it to a top discharge can be accomplished by f o l l o w i n g t h e s e i n s t r u c t i o n s . Th e u n i t c o m e s w i t h t h e Ve r t i c a l Di s c h ar g e d Ad ap t e r As s e m b l y &...
Page 13
INSTALLATION In s t al l t h e v e r t i c a l ad ap t e r at t h e SLIDE BRACK ET OVER d i s c h ar g e o f t h e b l o w e r . BLOWER DISCH ARG E, SECU RE WITH 8- 32 SCREWS Secure adapter bracket use (6)
INSTALLATION continued The alarm relay is activated by the Ansul® fire detection system. If the DANGER DANGER DANGER i n s t al l at i o n i n c l u d e s a b u i l d i n g al ar m s y s t e m , c o n n e c t...
INSTALLATION continued DANGER DANGER FIRE SUPPRESSION SYSTEM INSTALLATION (continued) BURN HAZARD BURN HAZARD Th e M ANU AL P U LL STATION an d an y s i m i l ar REM OTE M ANU AL An y ad d i t i o n al r e m o t e p u l l PULL STATION will activate the fire suppression system when the s t at i o n m u s t NOT b e i n s t al l e d...
Page 17
BURN HAZARD DO NOT operate any cooking DO NOT operate any cooking Use only genuine Wells replacement parts and filters, ap p l i an c e u n l e s s t h e g r e as e...
OPERATION CAUTION: CAUTION: Control Panel HOT SURFACE HOT SURFACE NOTE: Cooking appliances must Ex p Ex p o s e o s e d s u d s u r f ac e r f ac e s c a n b e h o t s c a n b e h o t b e o p e r at e d i n ac c o r d an c e...
CLEANING INSTRUCTIONS PRECAUTIONS: Di s c o n n e c t u n i t f r o m e l e c t r i c p o w e r an d al l o w t o c o CAUTION: CAUTION: Co v e...
Page 20
CLEANING INSTRUCTIONS PRECAUTIONS: Di s c o n n e c t u n i t f r o m e l e c t r i c p o w e r an d al l o w t o c o CAUTION: CAUTION: Cover cooking surfaces and frypots to prevent...
REQUIRED MAINTENANCE U SE AND M AINTENANCE SH ALL BE IN ACCORDANCE WITH TH E IMPORTANT: STANDARD FOR VENTILATION CONTROL AND FIRE P ROTECTION P e r NFP S 9 6, a s i g n e d an d OF COM M ERIAL COOK ING OP ERATIONS, N.F.P .A.
Page 24
ANSUL A N S U L IN C O R P O R AT E D MATERIAL SAFETY DATA SHEET ® M A R IN E T T E , W I 5 4 14 3-2 54 2 ANSULEX Low pH Q U IC K ID E N TIFIE R (In P la n t C o m m o n N a m e ) E m erg e nc y M a n u fac tu re r’s...
Page 25
ANSULEX Low pH (continued) SECTION 5 - HEALTH HAZARDS Th res h o ld N o ne E s tab lish ed L im it Va lu e : R o u te s o f E n try: Irritan t E ye C o n tac t: S kin C o n ta c t: Irritan t...
Filter pack plugged Replace filter pack Fire damper in exhaust collar has closed Contact an authorized Wells service agent for repairs SERVICE REQUIRED light lit (cooking One or more vacuum sensing lines or ports plugged, or Contact an authorized Wells service agent for repairs appliance not operating) sensing line dislodged.
WIRING DIAGRAM WVC-46 208/ 240 VOLT AC 60 H Z L2 P OWER SWITCH L2 1 2FLA 60RLA 1 20VAC 1 20 VOLT 8FLA 48LRA 250VAC WARNING CH ANG E 1 8A, 27 7 VAC RES BU Z Z ER CH ANG E P REFILTER FILTER...
EXPLODED VIEW & PARTS LIST Filter Maintenance Baf f l e Fi l t e r : 1 6” x 20” P r e - Fi l t e r H o o d P ar t No : 2I- Z 1 6860 P ar t No : 2I- Z 1 6882 G r e as e Cu p...
Page 29
EXPLODED VIEW & PARTS LIST Suppression System Model: WVU-46 Ventless Hood System SK2657 Rev. - 5/28/13 Suppression System WVC-46, Suppression System Fig No Part Number Description 2O-307481 ADAPTER SWIVEL ANSUL 2O-Z14574 NOZZLE, #245 2K-47269 ADAPTER 3/8IN QUICK CON A 2O-302931 NOZZLE 1 W 2O-Z15341 REGULATED ELEC.
Need help?
Do you have a question about the WVC46 and is the answer not in the manual?
Questions and answers