Wells WVU-31CT Owner's Manual

Countertop ventless universal hood system for countertop electric appliances

Advertisement

Quick Links

IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
2M-Z17951, Rev. A
p/n
WELLS MANUFACTURING
10 Sunnen Dr., St. Louis, MO 63143
telephone: 314-678-6314
fax: 314-781-2714
www.wellsbloomfield.com
VENTLESS UNIVERSAL
COUNTERTOP ELECTRIC
IL2732
OWNERS MANUAL
COUNTERTOP
HOOD SYSTEM
for
APPLIANCES
MODEL
WVU-31CT
Manual Includes
INSTALLATION
USE & CARE

EXPLODED VIEW

PARTS LIST

WIRING DIAGRAM

14
M524
524
0417

Advertisement

Table of Contents
loading

Summary of Contents for Wells WVU-31CT

  • Page 1: Exploded View

    Additional manuals are available from your WELLS DEALER. THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any questions concerning installation, operation or maintenance of this equipment.
  • Page 2: Warranty

    LIMITED WARRANTY STATEMENT Unless otherwise specified, all commercial cooking charged by Wells Manufacturing for its products are based equipment manufactured by Wells Manufacturing is upon the limitations in this warranty. Seller’s obligation warranted against defects in materials and workmanship under this warranty is limited to the repair of defects without...
  • Page 3: Table Of Contents

    EXPLODED VIEW & PARTS LIST 28-33 INTRODUCTION Thank You for purchasing this Wells Manufacturing appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
  • Page 4: Warnings - English

    Additional manuals are available from your WELLS DEALER. THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any questions concerning installation, operation or maintenance of this equipment.
  • Page 5: Warnings - French

    WELLS. TOUTE PERSONNE INSTALLANT OU UTILISANT CET APPAREIL DOIT LIRE CE MANUEL ET S’ASSURER DE L’AVOIR COMPRIS. Veuillez contacter votre CONCESSIONNAIRE WELLS pour toute question concernant l’installation, l’utilisation ou l’entretien de cet équipement. DANGER AVERTISSEMENT : RISQUE D’INCENDIE...
  • Page 6: Clearances

    CLEARANCES ” 3 1 . 1 . 7 2 . 5 2 ” . 3 0 ” ” 1 8 ” 8 ” 8 ” . 7 8 5 ” 4 . 8 ” ” ” 5 6 . 7 .
  • Page 7: Fire Suppression System

    Fire Protection Agent in accordance with the distributor. hood system. DO NOT attempt to modify or This Wells Ventless System includes factory installed piping, plenum, bypass the fire suppression discharge nozzles, thermal detectors. system. An uncontrolled fire can cause serious injury or death.
  • Page 8: Features & Operating Controls

    FEATURES & OPERATING CONTROLS IL2735 Countertop Ventilator Section Operating Features & Controls...
  • Page 9: Features & Operating Controls

    FEATURES & OPERATING CONTROLS continued FEATURES & OPERATION CONTROLS ITEM NO DESCRIPTION COMMENT DISCHARGE NOZZLES Fire suppression media discharges here, (5 places) VENTILATOR FAN Provides air movement for ventilation DETECTION END OF LINE RELAY Prevents appliance operation if a fault is found in detection circuit. VENTILATOR EXHAUST DUCT, FRONT Exit point for ventilator airflow - on front of unit.
  • Page 10: Precautions & General Information

    This appliance is made in the USA. Unless otherwise noted, this of business due to a filter appliance has American sizes on all hardware. related shutdown. Spare filters can be purchased from any authorized Wells servicer or calling Wells.
  • Page 11: Agency Listing Information

    AGENCY LISTING INFORMATION This appliance conforms to NSF Standard 2 for sanitation only if installed in accordance with the supplied Installation Instructions and operated and maintained in accordance with the instructions in this manual. This appliance is ETL listed. UL710B STD 2 Recurculating System INSTALLATION...
  • Page 12: Under-Hood Appliance Limitations

    Electrical appliances only. Not Intended for gas fired units. All appliances under the hood must be connected to the hood appliance interlock circuit. All appliances must meet the requirements outlined in the cooking appliance limitations chart below. EQUIPMENT PARAMETER WVU-31CT Maximum Single Dim A,...
  • Page 13: Service Technician Installation Notes

    INSTALLATION (continued) SERVICE TECHNICIAN INSTALLATION NOTES This ventilator hood is to be used with light-duty and medium-duty electrically powered cooking appliances only. DANGER: • DO NOT attempt to use this ventilator hood with gas-fired units. SUFFOCATION HAZARD • DO NOT use this ventilator hood with electrical appliances whose Do not attempt to use this dimensions or wattage characteristics exceed those defined in the ventilator with gas-fired units.
  • Page 14: Site Preparation

    INSTALLATION (continued) Site Preparation 1. Provide clearance around installation site to safety lift equipment into its final position. Consider general service and installation space when locating unit. 2. Thoroughly review the plans and specification of the project. 3. Determine the exact location in which the cooking hood will be installed and verify that there are no interferences, which will prevent proper installation.
  • Page 15: Mechanical Installation

    INSTALLATION (continued) MECHANICAL INSTALLATION The following is a step-by-step procedure for installation of the Recirculating Hoods. 1. Uncrate the hood, being very careful not to dent or scratch the outer surface. NOTE: Report any damage to the delivering freight carrier and file a claim if appropriate. Check the nameplate on the equipment to make certain it meets the specifications provided by the architect and or engineer.
  • Page 16: Electrical Installation

    INSTALLATION ELECTRICAL INSTALLATION Refer to the nameplate on the ventilator. Verify ELECTRICAL SERVICE POWER. Voltage and phase must match the nameplate DANGER: specifications, and available electrical service amperage must meet or SUFFOCATION HAZARD exceed the listed amperage. Refer to specifications listed on page 1 of this manual.
  • Page 17 INSTALLATION continued The ventilator will operate properly, and the appliance control relay will DANGER be energized, only when: FIRE HAZARD 1. The VENTILATOR POWER SWITCH is “ON”. Fire suppression system 2. The Ansul® Fire Suppression System is charged and armed. must be charged and certified 3.
  • Page 18: Fire Suppression System Installation

    INSTALLATION continued DANGER FIRE SUPPRESSION SYSTEM INSTALLATION BURN HAZARD THE FIRE SUPPRESSION SYSTEM is supplied by the customer with the exception of the piping, nozzles and thermal detectors. Any additional remote pull The hood is not supplied with a field installed MANUAL PULL station must NOT be installed STATION, which must be set-up at the time of installation by an on the front of the cooking...
  • Page 19: Filter Installation

    Moisture dripping onto hot Use only genuine Wells replacement parts and filters, surfaces, oil or grease can call (314) 678-6314 or your authorized Wells service agent. Parts cause splattering. supplied by others will void your warranty and may not provide safe operation.
  • Page 20: Operation

    A failure of incoming electric power will cause a shut down of the unit. cleaned. Reset the unit by turning VENTILATOR POWER SWITCH to OFF, then back to ON. Wells Manufacturing assumes no liability for loss of business Operation Lights due to filter related shutdown.
  • Page 21: Cleaning Instructions

    CLEANING INSTRUCTIONS PRECAUTIONS: Disconnect unit from electric power and allow to cool CAUTION: Cover frypot to prevent oil contamination HOT SURFACE FREQUENCY: Weekly Exposed surfaces can be hot to the touch and may cause TOOLS: Mild detergent, clean non-abrasive towels burns.
  • Page 22 CLEANING INSTRUCTIONS PRECAUTIONS: Disconnect unit from electric power and allow to cool CAUTION: Cover cooking surfaces and frypots to prevent HOT SURFACE contamination. Exposed surfaces can be hot FREQUENCY: Monthly to the touch and may cause burns. Allow unit to cool TOOLS: Mild detergent, clean non-abrasive towels before cleaning.
  • Page 23: Required Maintenance & Maintenance Logs

    REQUIRED MAINTENANCE IMPORTANT: USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION Per NFPA 96, a signed and OF COMMERIAL COOKING OPERATIONS, N.F.P.A. 96 (current dated VENTILATOR HOOD edition). MAINTENANCE LOG must be maintained on the premises, and be made 3-MONTH MAINTENANCE: available for inspection by the...
  • Page 26 ANSUL A N S U L IN C O R P O R AT E D MATERIAL SAFETY DATA SHEET ® M A R IN E T T E , W I 5 4 14 3-2 54 2 ANSULEX Low pH Q U IC K ID E N TIFIE R (In P la n t C o m m o n N a m e ) M a n u fac tu re r’s E m erg e nc y...
  • Page 27 SECTION 5 - HEALTH HAZARDS ANSULEX Low pH (continued) Th res h o ld N o ne E s tab lish ed L im it Va lu e : R o u te s o f E n try: Irritan t E ye C o n tac t: S kin C o n ta c t: Irritan t...
  • Page 28: Troubleshooting Suggestions

    Filter pack plugged Replace filter pack Fire damper in exhaust collar has closed Contact an authorized Wells service agent for repairs SERVICE REQUIRED light lit (cooking One or more vacuum sensing lines or ports plugged, or Contact an authorized Wells service agent for repairs appliance not operating) sensing line dislodged.
  • Page 29: Wiring Diagram

    WIRING DIAGRAM SUPPLIED CUSTOMER N.O. N.C.
  • Page 30: Exploded View & Parts List

    EXPLODED VIEW & PARTS LIST Filter Maintenance Pre-Filter Hood Part No: 2I-302579 Baffle Filter: 12” x 25” Part No: 2I-Z17655 Grease Cup Part No: 2D-Z14672 Filter HEPA/Carbon Pack Part No: N1-WL0422 Model: WVU-31CT Maintenance Parts SK2747 Rev. a, 4/16/2014...
  • Page 31 EXPLODED VIEW & PARTS LIST Suppression System Adapter 3/8” Quick Connect Part No: 2K-47269 Adapter Swivel Ansul Part No: 2D-307483 Nozzel 1W Part No: 2O-302931 O-Ring Part No: 2I-Z18157 Model: WVU-31CT Suppression System SK2748 Rev. A, 4/17/2014...
  • Page 32 EXPLODED VIEW Main Assembly 14 15 4 18 Model: WVU-31CT Main Assembly SK2750 Rev. A, 4/22/2014...
  • Page 33 PARTS LIST Main Assembly Model: WVU-31CT Main Assembly Fig No Part Number Quantity Description N1-Z17756 TOP COVER PANEL, REAR N1-Z17755 TOP COVER PANEL, FRONT N1-Z17687 AIR DEFLECTOR PLATE 2C-6349 SCREW #8X3/8 B THP STL NP 2C-42066 SCREW 6-32X1 PH RD HD NI...
  • Page 34 EXPLODED VIEW Controls Assembly 14 12 Model: WVU-31CT Controls Assembly SK2751 Rev. A, 4/22/2014...
  • Page 35 PARTS LIST Controls Assembly Model: WVU-31CT Control Assembly Fig No Part Number Quantity Description 2M-306719 LOGO WELLS DIECAST SHIELD N1-WL0480 DOOR ASSEMBLY, LEFT N1-WL0245 LED LIGHT W/TERMINALS 2C-Z14619 SCREW 4-40X1/4 PH PAN HD 2C-200014 SCREW 8-32X3/8 THP SS N1-Z18155 TERMINAL BLOCK ASSY...
  • Page 36 NOTE...
  • Page 37 NOTE...
  • Page 38 NOTE...
  • Page 39: Customer Service Data

    IMPORTANT: Use only factory authorized service parts and replacement filters. For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Manufacturing 10 Sunnen Dr. St. Louis MO 63143 USA Service Dept.
  • Page 40 WELLS MANUFACTURING 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.com...

Table of Contents