    CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY AND KEEP THEM FOR FUTURE REFERENCE Please read this manual carefully to help you understand all of the information and to ensure safe installation, use and servicing. We are not held liable for any damage arising due to a failure to respect the instructions set out in this manual.
  • Page 3 CONTENTS Control box ........................p. 20 Wiring for AQUA1 control box with Wi-Key control ............ p. 21 Wiring for AQUA1 control box with key switch control ..........p. 22 Wiring for MIT 5210-7210 (DL motor) control box with Wi-Key control .....p. 23 Wiring for MIT 5210-7210 (DL motor) control box with key switch ........p.
  • Page 4: Description

    DESCRIPTION COMPONENTS PROVIDED WHITE GOODS 6 x 30 Stainless-steel Screw Joint Joint flange Motor side free side Bag of loose fittings INSTALLATION KIT 6 x 30 8 x 40 10 x 60 Ø8 Stainless- Screw Screw Screw Sleeve steel Joint Free flange bearing...
  • Page 5 DESCRIPTION COUNTERWEIGHTS REEL SYSTEM Counterweight Allen key Quantity variable male No. 4 depending on width of pool Anodised aluminium reel system BEAM SUPPORTS – Model and colour according to order (1 Packing) Pegged Adjustable insert mount façade hanging mount BEAM – Model according to order MIDDLE TELESCOPIC SUPPORT (1 Packing) (1 Packing)
  • Page 6: Tools Required For Assembly

    DESCRIPTION TOOLS REQUIRED FOR ASSEMBLY PACKING LIST ASSEMBLY Example – for a 5.00 x 10.00m pool with roman stairs Deck + Plates+control box: 1 0.65 x 0.45 x 0.25/40kg Packing 2 persons Reel system with motor: 1 0.15 x 0.15 x 5.10 m/40kg Packing Beam: 1 0.15 x 0.15 x 5.10m/34kg Packing Beam support: 1 0.30 x 0.20 x 0.20m/10kg Packing 3 hours...
  • Page 7: Ensuring The Cover Complies With French Standards

    15cm max. 4cm min. • On infinity pools, DEL covers are not compatible unless the pool is equipped with a Viatalia INFINITY control box to automatically lower the water level by at least 2cm when the cover is closed over the pool.
  • Page 8: Installation

    INSTALLATION The walls of the housing must be vertical and parallel with each other. L = Pool length (including stairs and housing) 40 min. Skimmer 150 max. 50 min. Overflow water level regulator / 2) + 25 / 2) - 25 Separating wall made of traditional masonry.
  • Page 9 INSTALLATION < 6 (in m) to 7 to 8 to 9 to 10 to 11 to 12 to 13 to 14 to 15 to 16 to 17 (in mm) Decking Decking 750mm 900mm (in m) to 18 to 19 to 20 to 21 to 22 to 23...
  • Page 10: Motor Housing

    INSTALLATION MOTOR HOUSING The motor housing can be placed to the right or the left of the pool. from 200 to 260mm for standard white goods in mm INSTALLATION OF WHITE GOODS motor free side side motor side pool side the location for the waterproofing (lagging + rolling element bearing) is on the motor housing side...
  • Page 11: Installing The Motor Side Flange

    INSTALLATION INSTALLING THE MOTOR SIDE FLANGE For any other type of waterproofing, do not 6 x 30 Stainless-steel use joint No. 1 Joint Screw flange Liner 75/100ths Membrane 150/100ths - Prime (around 20cm) before fastening the flange. - Pierce the liner with an awl before bolting in. INSTALLING THE FREE SIDE BEARING Free Ø10...
  • Page 12: Installation Of The Reel System

    INSTALLATION INSTALLATION OF THE REEL SYSTEM Ø6 PVC Spacers Allen key switch head washer male No. 4 bolts x 30 Bag of loose fittings switch head Ø6 PVC bolts x 30 washer...
  • Page 13: Installing The Motor

    INSTALLATION MOTOR HOUSING SIDE WATERPROOFING Rolling ele- Spring 6 x 30 Stainless- ment-bearing washer Screw steel flange • The spring needs to rest against the rolling- element bearing • Grease the stainless- Do not use a hammer to steel axis in order to assemble the spring washer put the rolling-element and the rolling-element bearing,...
  • Page 14 INSTALLATION INSTALLING THE MOTOR N° 17 N° 13 MCA120 MCA250 DL6010/7710 DL6010 FASTENING N° 13 Ø10 8 x 40 Ø10 Sleeve Screw Ø8 Washer MCA120 MCA250 DL6010/7710 INSTALLING THE PIN DL6010/7710 MCA120 MCA250 DL6010...
  • Page 15 INSTALLATION INSTALLING THE PROTECTIVE HOOD FOR THE MOTOR N° 10 Ø8 6 x 30 Ø8 Screw Sleeve Ø6 Washer MCA120 MCA250 DL6010/7710 Option: 6-pin connector “page 25”...
  • Page 16: Beam Support

    INSTALLATION BEAM SUPPORT ADJUSTABLE HANGING MOUNT VERSION TF M8x80 For concrete or panel pools stainless Hanging mount steel bolt bracket Ø12 A4 M10 Stainless-steel nut Ø12 nylon Sleeve Fastening on panels: M8 nut Ø8 Washer M8x20 bolts VERSION THAT NEEDS INSERT MOUNT For concrete pools Joint 1 Joint 2...
  • Page 17 INSTALLATION PEGGED FAÇADE VERSION For pools made of concrete and concrete blocks, as Universal Sleeve 12 well as for pools whose walls are 8mm thick or more x 60 Ø8 washer 4 x 24 TH M8x80 Screw Concrete Concrete block Washer Washer Sleeve...
  • Page 18: Installing The Beam

    INSTALLATION INSTALLING THE BEAM Pool cover housing side MIDDLE TELESCOPIC SUPPORT Middle telescopic support For pools that are more than 6m wide, remember to install 1 or 2 intermediate Beam supports in order to support the centre of the beam (see enclosed leaflet). INSTALLING THE COUNTERWEIGHTS The counterweights ensure that the cover is rolled up correctly by “holding”...
  • Page 19: Installation Of The Counterweights

    The use of decking that do not comply with the standard will de facto render the entirety of the installa- tion non-compliant. In order for the duckboard to comply with standard NF P90-308, DEL recommends that the following instructions must be respected: •...
  • Page 20 INSTALLATION ELECTRICAL CONTROL BOX MOUNTING THE CONTROL BOX • The control box must be fixed to the wall of the equipment room in an easily accessible position, between 1 metre and 1.80 metres above the floor. • The box must be securely fixed to the wall using the screws and plugs supplied with it. •...
  • Page 21: Control Box

    INSTALLATION CONTROL BOX The electrical connection of the equipment must only be carried out by a qualified professional, and they must comply with the manufacturer’s instructions in addition to the following applicable standards and regulations: - NF C15-100: Low voltage electrical installations. - CEI 60364: Electrical installations for buildings.
  • Page 22: Wiring For Aqua1 Control Box With Wi-Key Control

    INSTALLATION Ensure that there is no-one in the pool when carrying out the operation. WIRING FOR AQUA1 CONTROL BOX WITH WI-KEY CONTROL *see comments and diagrams on page 25 NO C NC NO C NC Stop Flow 30mA residual circuit breaker.
  • Page 23: Wiring For Aqua1 Control Box With Key Switch Control

    INSTALLATION WIRING FOR AQUA1 CONTROL BOX WITH KEY SWITCH CONTROL *see comments and diagrams on page 25 NO C NC NO C NC STOP FLOW 30mA residual circuit breaker. over contact for 3 x 1.5 mm 2 electrolytic unit OPTION 6-pin connector Connection see page 36...
  • Page 24: Wiring For Mit 5210-7210 (Dl Motor) Control Box With Wi-Key Control

    INSTALLATION WIRING FOR MIT 5210-7210 CONTROL BOX WITH WI-KEY CONTROL *see comments and diagrams on page 25 *Filtration housing contactor 230 V contactor Stop flow 30mA residual circuit breaker Connection Socket 230 Volts Single-phase 50Hz limit switch cable DL6010 / DL7010 motor cable...
  • Page 25: Wiring For Mit 5210-7210 (Dl Motor) Control Box With Key Switch

    INSTALLATION WIRING FOR MIT 5210-7210 CONTROL BOX WITH KEY SWITCH BOX *see comments and diagrams on page 25 *Filtration housing contactor 230 V contactor Stop flow 30mA residual circuit breaker Connection Socket 230 Volts Single-phase 50Hz limit switch cable DL6010 / DL7010 motor cable...
  • Page 26 INSTALLATION * “PUMP” terminal block Piloting the filtration pump. When the cover is moving: Contact C-NO open (stop filtration) and contact C-NC closed (filtration). BEFORE AFTER ** “SALT” terminal block electrolyser control From 80% closed: Contact C-NO closed and contact C-NC open From 20% open: Contact C-NO open and contact C-NC closed The position of the dry contact is saved in the memory in case power to the control box is ever switched off.
  • Page 27: Wiring For 6-Pin Connector - Option

    INSTALLATION WIRING FOR 6-PIN CONNECTOR – OPTION The connector allows you to disconnect the geared motor very quickly, without any need to carry out any operations on the electrical wiring. For Wintering, replace the geared motor with the Wintering lever. 27 27...
  • Page 28: Wi-Key Control

    INSTALLATION WI-KEY CONTROL Flashing red/green = emitter locked See emitter unlocking procedure page 29 Emitter Receiver Manufacturer Reference Wi-Key receiver Wi-Key emitter Category 3 (EN 300220-1) 2 (EN300220-1) 50m open field range 50m open field range Range 25m through a concrete 25m through a concrete wall wall...
  • Page 29 INSTALLATION • It must be located in a place that allows the operator to check that no-one is in the pool during the operation. • It is compulsory for the locking “bar” to be installed and bolted into place. • Before fastening the control box, ensure that the emitter is communicating with the receiver.
  • Page 30 INSTALLATION Emitter Press “STOP” and hold the switch down, then press “O” for more than 3 seconds OK when the “Indicator light” flashes red/green. Indicator light STOP Connection of a new emitter must be carried out within the following 30 seconds. LOCK WI-KEY •...
  • Page 31: Calibrating Limit Switches (Mca120 - Mca250 Motor)

    INSTALLATION CALIBRATING THE LIMIT SWITCHES (MCA120-MCA250 MOTOR) Any person carrying out work on the electrical parts must be qualified and wear PPE (personal protective equipment): gloves, goggles, mat, etc… CHECKING THE POSITION OF THE LIMIT SWITCH UNSCREW THE CAM CAMS LOCKING BOLTS Motor position Allen key...
  • Page 32 INSTALLATION VERIFICATION OF THE CONTROL LOGIC Close pool Contact maintained Open pool If the control logic is not respected, check the wiring of the installation. PUT THE COVER INTO THE “POOL OPEN” POSITION Adjust the position of the cover by using the 2 controls “open and close”.
  • Page 33 INSTALLATION PUT THE COVER INTO “POOL CLOSED” POSITION Adjust the position of the cover by using the 2 controls “open and close”. Warning: the last control used must be to close the pool. If the cover does not close, check the control logic and start the whole limit switch calibration procedure again.
  • Page 34: Automatic Switch (Mca120-Mca250 Motor)

    INSTALLATION AUTOMATIC SWITCH (MCA120-MCA250 MOTOR) The automatic switch protects the system from any potential oversights with regard to the unlocking of the fastening control boxs, when the pool is opened. If the cover is blocked, the motor will stop automatically. The different reasons for a blockage: •...
  • Page 35 INSTALLATION VERIFICATION OF THE CONTROL LOGIC FOR THE AUTOMATIC SWITCH Any person carrying out work on the electrical parts must be qualified and wear PPE (personal protective equipment): gloves, goggles, mat, etc… DEACTIVATING THE AUTOMATIC SWITCH (Switch PROG) Deactivated CHECK WIRING I N D I C A T O R L I G H T S Indicator...
  • Page 36: Rewinder Model Calibration (Settings Switch)

    INSTALLATION REWINDER MODEL CALIBRATION (SETTINGS SWITCH) 2 3 4 CONTROL PERIOD CALIBRATION (SETTINGS SWITCH) L ≤ 12 m L > 12 m L = pool length including stairs 2 3 4 2 3 4 30 seconds 60 seconds TRIGGERING SENSITIVITY CALIBRATION (PROG SWITCH) l = pool width l ≤...
  • Page 37: Important

    INSTALLATION IMPORTANT Contact maintained for more than 3 secs more than 3 secs Close The next opening will be protected less than 3 secs Contact maintained for less than 3 secs Close The next opening will not be protected TEST A - Block the cover manually or use the fastening equipment, and open the pool.
  • Page 38: Calibration Of Limit Switches (Mit5210 - Mit7210 Motor)

    INSTALLATION Any person carrying out work on the electrical parts must be qualified and wear PPE (personal protective equipment): gloves, goggles, mat, etc… Warning: use of the pool cover control switchs present in the housing (Wi-Key receiver) must only be carried out by a person who is absolutely certain that there is no risk and that no-one will enter the pool during the operation.
  • Page 39: Servicing/Maintenance

    SERVICING/MAINTENANCE Any person carrying out work on the electrical parts must be qualified and they must comply with the manufacturer’s instructions in addition to the applicable standards and regulations. During any intervention, the technician must wear PPE (personal protective equip- ment): gloves, goggles, mat, etc…...
  • Page 40: Care & Maintenance

    CARE / MAINTENANCE CARE (responsibility of the customer) • Clean your slatted cover thoroughly twice a year (when opening the pool for the season and when winterising it). This is even more important if your pool water is hard. To do this, use a descaling cleaner (see catalogue) and rinse with a water spray. •...
  • Page 41 SERVICING/MAINTENANCE MAINTENANCE (ONCE PER YEAR MINIMUM) • All interventions must be carried out by a professional, who will contact the manufacturer if necessary (contact details on the back page of this document). • All spare parts must come from the manufacturer or comply with standard NF P90-308. •...
  • Page 42: Maintenance

    MAINTENANCE WINTERING CRANK – OPTION Aim: to allow the motor to overwinter while ensuring that the pool is safe. Motor bolt Motor Crank Unfold the crank buffer...
  • Page 43: Wintering

    SERVICING/MAINTENANCE WINTERING • Position the cover in the closed position and keep the water level constant in accordance with the manufacturer's recommendations. Between 7 and 15 cm • During the winter season, in the event of snowfall, it is essential to remove snow from the roof using a brush with a telescopic handle.
  • Page 44: Safety Advice

    SAFETY ADVICE Dear Customers, Thank you for placing your trust in us by selecting a safety cover made by DEL. Please read the recommendations set out below with care. WARNING Swimming pools can represent a serious danger for your children. Drowning can happen very quickly.
  • Page 45 SAFETY ADVICE • This section is by no means a replacement for common sense or individual responsibility. Its aim is not to replace the vigilance of parents and/or responsible adults, who remain the essential factor in ensuring the protection of young children. •...
  • Page 46: Recycling

    RECYCLING PACKAGING Dispose of the packaging in line with current rules and regulations. END OF LIFECYCLE • Do not put your scrapped equipment or used batteries in with unsorted household waste. • You are responsible for disposing of all of your waste, in particular electrical and electronic equipment by taking it to a collection point where recycling and valorisation are carried out.
  • Page 47: Warranty Condition

    REGULATIONS STANDARD • This cover complies with standard NF P90-308. WARRANTY CONDITION log on to www.del-piscine.fr to consult all our guarantees. https://www.del-piscine.fr/rechercher-une-garantie...
  • Page 48 DEL SAS ZA LA BASSE CROIX ROUGE 35530 BRÉCÉ - FRANCE +33 (0)2 99 00 17 72 STAMP A brand by CF group...