Friax SPC-HEVA2 Ceos Technical Installation Manual

Gch air condensing unit

Advertisement

Quick Links

Technical installation manual
SPC-HEVA2 Céos
GCH air condensing unit
The characteristics given in this technical sheet may change without
prior notice, with the improvements that «FRIAX Industrie» always in-
tends to make to its production.
EN-NT-SPC-HEVA2-CSX-0125

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPC-HEVA2 Ceos and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Friax SPC-HEVA2 Ceos

  • Page 1 Technical installation manual SPC-HEVA2 Céos GCH air condensing unit The characteristics given in this technical sheet may change without prior notice, with the improvements that «FRIAX Industrie» always in- tends to make to its production. EN-NT-SPC-HEVA2-CSX-0125...
  • Page 2 Warning Read the manual carrefully before using the device and keep it for futur reference. This symbol indicates that the installation manual should be read carrefully. This symbol indicates that a technician must handle this equipment in referring to the installation manual. This symbol indicates that information are available, such as the manual operating instructions or installation manual.
  • Page 3: Table Of Contents

    Summary Presentation ................................. 4 Receipt of the package ............................... 4 Technical data ..............................5 Electrical connections ............................6 Schematic diagram ..............................6 Indoor unit ................................7 Dimensions ................................... 7 Product presentation ..............................8 Installation of the Up/Down EVA2 mounting fan ....................... 9 Set up ..................................
  • Page 4: Presentation

    Presentation Thank you for choosing a Friax cellar system to control the aging of your wines. Take the time to read this user manual. It will allow you to understand and master the operations to install and adjust your device.
  • Page 5: Technical Data

    Technical data Technical data +32°C EXT Fluid R513A R513A R513A R513A R513A 1130 1470 2370 2750 1266 1433 Max Intensity Amax 6.09 6.19 9.59 11.84 13.56 C.O.P Air conditioner 1.43 1.62 1.66 1.87 1.92 Outdoor unit 50HZ 230V/1+T 230V/1+T 230V/1+T 230V/1+T 230V/1+T m3/h 1025...
  • Page 6: Electrical Connections

    Electrical connections Models SPC GCH 30-48-82 Voltage/Frequency 230V / 50Hz 230V / 50Hz 230V / 50Hz Protection Power supply to control Box 3g1.5² 3g1.5² 3g2.5² Indoor Unit ==> Control box 1 x (5g1.5²) 2 x (5g1.5²) 2 x (5g1.5²) Max length 6 meters 1 x (3 x 1mm²) 2 x (3 x 1mm²) 2 x (3 x 1mm²)
  • Page 7: Indoor Unit

    Indoor unit Indoor unit Dimensions Dimensions SPC 30 SPC 48 SPC 82 SPC 122 SPC 170 Number of evaporators Down blowing COUPE B-B COUPE A-A Upward blowing...
  • Page 8: Product Presentation

    Product presentation Blowing side view Extension, grille and screws delivered in a bag Breakable part for assembly Breakable part for tube passage grille in UP assembly only by the top water solenoid valve Liquid line connection Suction line connection Fan position UP Fig 1 Breakable part for passage Breakable part for connection...
  • Page 9: Installation Of The Up/Down Eva2 Mounting Fan

    Installation of the Up/Down EVA2 mounting fan Your EVA2 evaporator is delivered to you in the UP version without the assembly of the grid and its extension. UP mounting N°1 Fig 1 Fig 2 Down mounting Follow the following steps for fan positioning Fig 4 Fig 3 upwards and pull it out towards you.
  • Page 10: Set Up

    Set up Cabinets with clas- Cabinets with sic bottle racks VisioRack mini 40 mini 80 mini Recessed into 20mm furniture blow down or up Down blowing Provide access to the evaporator for maintenance Up blowing mini mini Top view Glass door...
  • Page 11: Drain Connection

    Drain connection Connect the drain tube (ø 15) to the end of the elbow and tighten with a stainless steel collar Ø 15mm Ø 15mm drain tube (ø 15) Water connection for Vintage Electro-Valves connection (20/27 mm) Pre-cut facade for klpwsecu tube passage In case of water pressure greater than 2.8 bars, the use of a pressure limiter kit is essential...
  • Page 12: Outdoor Unit Gch Air Group

    Outdoor unit GCH air group Dimensions GCH 30-48 Groups 4 x Ø11 Baton safety ~116°...
  • Page 13: Dimensions Gch 82-122 Groups

    Dimensions GCH 82-122 Groups 4 x Ø11 Baton safety ~116°...
  • Page 14: Dimensions Gch 170 Groups

    Dimensions GCH 170 Groups 4 x Ø11 Baton safety...
  • Page 15: Fixing Gch Groups 30 To 170

    Advice: -Raise the unit to avoid leaves and snow. -Favour open areas, out of the sun -Check the solidity of the supports. -Beware of noise for neighbours. Installation with KS2M kit (list of accessories) 133 mm 100 mm 100 mm minimum minimum...
  • Page 16: Cover Removal

    Cover removal...
  • Page 17: Refrigeration Connection

    Refrigeration connection Be sure to read this carefully before installing your FRIAX equipment if the outdoor unit is above the evaporator. hauteur maxi...
  • Page 18: Refrigeration Diagram Spc 30-48-82 Eva2

    Refrigeration diagram SPC 30-48-82 EVA2 SPC 30-48-82 3/8“ 1/4“ 1/4“ EVA2 1/4“ 3/8“ SPC 122 Refrigeration diagram SPC 122 EVA2 1/2“ 1/4“ 1/4“ EVA2 1/4“ 3/8“ EVA2 1/4“ 3/8“...
  • Page 19: Refrigeration Diagram Spc 170 Eva2

    Refrigeration diagram SPC 170 EVA2 SPC 170 5/8“ 3/8“ 3/8“ EVA2 1/4“ 3/8“ EVA2 1/4“ 3/8“...
  • Page 20: Shaping Refrigeration Pipes

    pipe in Compliant Improper 1-Cut the copper pipe correctly with a pipe cutter copper 90° (Fig1, 2). 2- Deburr gently while holding the pipe downwards to Fig.1 Fig.2 3-Remove the “FLARE” nuts attached to the device pipe in copper Flaring Tool slip them onto the pipes after removing all burrs.
  • Page 21: Using The Vacuum Pump

    Using the vacuum pump 1-Remove the charging port caps (Schrader) from the service valves of the gas lines and liquid lines of the outdoor unit (Fig8). 2-Connect the charging pipes to the schraders of the gas (Blue) and liquid (Red) side service ports. 3-Connect the charging hose (yellow) to the vacuum pump nozzle.
  • Page 22: Handling Of Valves

    Handling of valves Once the vacuum is complete, 1- Fully open the control rods by turning them outwards but do not try to open them beyond the stop. (Start with the liquid side then the gas side). 2-Start the air conditioner and wait for a while, check the gas charge, the liquid indicator should not be bub- bling.
  • Page 23: Electrical Connection

    Electrical connection 4 x Ø6.2 Cellar T° probe COND=Condenser probe 1=Casing resistance 3L= EV Pump Down SPC170-230 3 pole connector Evaporator fan control 2N=Neutral EXT group 5=Compressor supply spc170-230 4=Condenser fan 7-8-9 = Condenser fan control 5 pole connector N-L 230V box power supply 3L=Compressor spc evaporator supply 30-48 82-122...
  • Page 24: Probe Placement And Connection

    Probe placement and connection The remote control box comes with: - a remote control and its support - 2 LR03 batteries - A probe installed in its support supplied with: - screws and their plugs (wall mounting) The class 6 RJ straight cable with a length of 6 m is supplied with the regulation box Connector RJ45 probe...
  • Page 25: Installing The Connectors

    Installing the connectors 3 connectors are delivered to you in a bag in the evaporator box, for be connected to your cables following the assembly below. 1. Stripping length = 30 mm (2 poles), 37 mm (3 poles), 45 mm (4 and 5 poles) 2.
  • Page 26: Air Group Spc 30-48-82-Heva2 Céos

    Air group SPC 30-48-82-HEVA2 Céos Control box COND/ AMB Cable RJ12 Switch 7 8 9 N L 2N2N 3L PEPE 3G1,5² Power Supply 20A 230V+T 3 2 1 3 2 1 Hygo-temperature probe 5 G 1,5² 2 x 0.5² 3x1² Drain pump 5 G 1.5²...
  • Page 27: Air Group Spc 122-Heva2 Céos

    Air group SPC 122-HEVA2 Céos Control box COND/ AMB Cable RJ12 Switch 7 8 9 N L 2N2N 3L PEPE 3G1,5² Power Supply 20A 230V+T 1 2 3 1 2 3 Hygo-temperature probe 5 G 1,5² 1 2 3 1 2 3 2 x 0.5²...
  • Page 28: Air Group Spc 170-Heva2 Céos

    Air group SPC 170-HEVA2 Céos Control box COND/ AMB Switch Cable RJ12 7 8 9 N L 2N2N 3L PEPE 3G2,5² Power Supply 20A 230V+T 1 2 3 1 2 3 2 x 0.5² Hygo-temperature probe 5 G 2,5² 1 2 3 1 2 3 3x1²...
  • Page 29: Lighting Function

    The card is equipped with an auxiliary contact COM-NO-NC 2 functions can be associated with the auxiliary contact: 16 A max - ECL lighting function - Alarm reporting function The card is basically programmed for lighting function. Lighting function: To turn on the lighting, refer to the RSF2 Commissioning & Use instructions, ==>Summary==>Menu architecture==>Menu 3 FUNC Lig ON/OFF command.
  • Page 30: Maintaining Your Cellar Air Conditioner

    Maintaining your cellar air conditioner The following maintenance operations, repeated every 6 months, will ensure that your air conditioner re- tains its optimum performance and lasts as long as you and your wine. Warning! Before any maintenance operations, turn off the device using the remote control then cut off the power sup- ply at the main circuit breaker to avoid any risk of electrocution.
  • Page 31 NOTES...
  • Page 32 231/233 Rue de la Prairie F-73420 Voglans Site web : www.friax.fr info @friax.fr Boite mail : Découvrez notre gamme de rangement pour la cave ! VisioRack ® L'agencement du vin www.visiorack.com...