Vivosun ZX11008 User Manual

Shallow well pump

Advertisement

Quick Links

Shallow Well Pump
Shallow Well Pump
User Manual
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZX11008 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vivosun ZX11008

  • Page 1 Shallow Well Pump Shallow Well Pump User Manual User Manual...
  • Page 2: Table Of Contents

    Welcome to Contents Thank you for choosing Vivosun! We are Attention committed to product quality and friendly customer service. If you have any questions or Specification Parameters suggestions, please don’t hesitate to contact us. Warning Installation Operation Maintenance Troubleshooting Parts List and Diagram...
  • Page 3: Attention

    Specification Parameters be avoided at all costs. The pump must be protected from frost. The pump must be protected from running dry. Model ZX11008 Max Flow 1320 GPH Suction 26ft Access by children should also be prevented with appropriate measures.
  • Page 4: Installation

    Installation Installation Areas of use The pump must be installed in a stationary position with either: a. A fixed pipeline or b. A flexible hose pipe. This pump is designed to pump water only. This pump is designed to be used for: Please note! Pumping drinking water from shallow wells and cisterns.
  • Page 5 Installation Installation The illustration below shows an example of a proper shallow well pump For your protection, the power outlet used should have a Ground Fault Circuit installation. The total suction lift (vertical well lift + length of o -set line) must not Interrupter (GFCI).
  • Page 6: Operation

    Operation Maintenance After reading these instructions, consider the following points before starting the pump: Warning The Compression Tank has a rubber bladder inside that has been pressurized to TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Unplug the 23 PSI. Remove the cover over the air valve (on the tank end opposite the pipe Pump from its electrical outlet before performing any inspection, maintenance, or connection) and periodically monitor this air valve with an air pressure gauge to cleaning procedures.
  • Page 7: Troubleshooting

    Troubleshooting Troubleshooting Problem Cause Solution Follow all safety precautions whenever diagnosing or servicing the Pump/motor cycles Cut-in and cut-out pressure Have the pressure switch adjusted pump. Disconnect power supply before service. rapidly may be set too closely. by a qualified technician. Do not disassemble the pump or motor as this will damage the water Tank bladder will 1.
  • Page 8: Parts List And Diagram

    Troubleshooting Parts List and Diagram Part Description Qty. Part Description Qty. Part Description Qty. Problem Cause Solution Plug and Cable Bolt Flexible Tube Motor runs, but 1. Improper priming. 1. Prime the pump by pouring clean Pressure Switch Terminal Box Gasket water is not 2.

Table of Contents