DIGITAL-LOGIC MICROSPACE Workstation 2 MSWS2 Technical User's Manual

Table of Contents

Advertisement

Quick Links

TECHNICAL USER'S MANUAL FOR:
Workstation 2
MSWS2
Nordstrasse 4F, CH-4542 Luterbach
Tel.: +41 (0)32 681 53 36 - Fax: +41 (0)32 681 53 31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MICROSPACE Workstation 2 MSWS2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DIGITAL-LOGIC MICROSPACE Workstation 2 MSWS2

  • Page 1 TECHNICAL USER'S MANUAL FOR: Workstation 2 MSWS2 Nordstrasse 4F, CH-4542 Luterbach Tel.: +41 (0)32 681 53 36 - Fax: +41 (0)32 681 53 31...
  • Page 2: Revision History

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 COPYRIGHT © © © © 1992-95 BY DIGITAL-LOGIC AG No part of this document may be reproduced, transmitted, transcribed, stored in a retrieval system, in any form or by any means, electronic, mechanical, optical, manual, or otherwise, without the prior written permission of DIGITAL-LOGIC AG.
  • Page 3: Table Of Contents

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Table of Contents 1 PREFACE........................... 6 1.1 How to use this Manual .........................6 1.2 Trademarks...........................6 1.3 Disclaimer.............................6 1.4 Who should use this Product......................6 1.5 Recycling Information ........................7 1.6 Technical Support .........................7 1.7 Limited Warranty ..........................7 2 OVERVIEW ........................
  • Page 4 DIGITAL-LOGIC AG MSWS2 Manual V2.31 4.8 VGA, LCD...........................29 4.8.1 VGA / LCD Controller 65540 / 65545 ..................29 4.8.2 Display Interface........................29 4.8.3 CRT Displays ........................29 4.8.4 VGA Controller Chips ......................29 4.8.5 Flatpanel Displays ........................30 4.8.6 Simultaneous Flatpanel / CRT Display ..................30 4.8.7 Simultaneous Display ......................30...
  • Page 5 DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.1.1 Multifunction Latch......................65 10.1.2 Programmable Contrast, Backlight and Speaker Volume ............66 10.1.2.1 Theory of adjusting Contrast and Backlight.................66 10.2 Special Function Interface SFI, Function INT 60 ...............67 10.2.1 EEPROM Functions:......................67 10.2.2 Adjusting the Contrast, Backlight and the Speaker volume:..........69 10.2.3 Hardware type INT 60:......................70...
  • Page 6: Preface

    The specifications given in this manual were correct at the time of printing; advances mean that some may have changed in the meantime. If errors are found, please notify DIGITAL-LOGIC AG at the address shown on the title page of this document, and we will correct them as soon as possible.
  • Page 7: Recycling Information

    DIGITAL-LOGIC AG), wrong connection, wrong information or as a result of service or modification by anyone other than DIGITAL-LOGIC AG. Neither if the user has not enough knowledge of these technologies or has not consulted the product manual or the technical support of DIGITAL-LOGIC AG and therefore the product has been damaged.
  • Page 8: Overview

    PC/104 embedded BUS PS/2 mouse Interface Unique Features The MICROSPACE MSWS2 includes all standard PC/AT functions plus unique DIGITAL-LOGIC AG en- hancements, such as: Solid state disk (SSD) 1 or 2 MBytes LCD interface with power supply for LCD-BIAS (-30 Volt to +30 Volt adjustable)
  • Page 9: Block Diagram

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Block Diagram The real Singleboard Industrial PC: Touchscreen DRAM Chipset 80486 DX 10Bit Y/X Green PC 80486 DX4 1 - 64 MBytes F840C41/45 80486 DX2 72 pins SIMM RTC / CMOS 80486 SX Overdrive P5-32...
  • Page 10: Msws2-486 Specifications

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 MSWS2-486 Specifications CPU: CPU 32 Bit: 80486DX, 80486DX/2, 80486DX/4, from AMD / TI / INTEL/CYRIX CPU 16 Bit: 80486SX Mode: Real / Protected Compatibility: 8086 - 80486 Word Size: 32 Bits Physical addressing: 32 lines...
  • Page 11 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Floppy disk interface, for max. 2 floppies, 26 and 34 pins connector IDE interface, AT - Type, for max. 2 harddisks, 40 and 44pins con- nector, onboard mounted harddisk: 2.5“ harddisk with 44 pins IDE...
  • Page 12: Ordering Codes

    10 G 0°C - 50 °C Temperature: Operating: Standard version: Extended version: contact DIGITAL-LOGIC AG -55° to +85 °C Storage: EMV / EMC (IEC1131-2 refer MIL 461/462): ESD Electro Static Discharge: IEC 801-2, EN55101-2, VDE 0843/0847 Part 2 metallic protection needed, separate Ground Layer...
  • Page 13: The At96 And Pc/104 Bus Signals

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 AT96 PC/104 B IGNALS AEN, output Address Enable is used to degate the microprocessor and other devices from the I/O channel to allow DMA transfers to take place. low = CPU Cycle , high = DMA Cycle...
  • Page 14 DIGITAL-LOGIC AG MSWS2 Manual V2.31 IRQ[ 3 - 7, 9 - 12, 14, 15], input These signals are used to tell the microprocessor that an I/O device needs attention. An interrupt request is generated when an IRQ line is raised from low to high. The line must be held high until the micro- processor acknowledges the interrupt request .
  • Page 15 DIGITAL-LOGIC AG MSWS2 Manual V2.31 SD[O..15], input/output These signals provide bus bits 0 through 15 for the microprocessor, memory, and I/0 devices. DO is the least-significant bit and D15 is the most significant bit. All 8-bit devices on the I/O channel should use DO through D7 for communications to the microprocessor.
  • Page 16: Expansion Bus

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Expansion Bus The Bus currents are: Output-Signals: IOH: IOL: D0 - D16 24mA 24mA A0 - A23: 24mA 24mA MR,MW,IOR,IOW, RES,ALE,AEN,C14 24mA 24mA DACKx, DRQx,INTx, PSx, OPW 24mA 24mA Input-Signals: Logic-Family: Voltage: ABT-Logic ABT-Logic Input Signals: ViH(min.) = 2.15V...
  • Page 17: Detailed System Description

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 ETAILED YSTEM ESCRIPTION This systems has a system configuration based on the ISA architecture. Check the I/O and the Memory map in this chapter. Power Requirements The power is connected through the AT96 Bus connector; or the PC/104 Power connector; or the sepa- rate power connector on the board.
  • Page 18: Interface

    'COM2' device. However, it is possible to disable either or both serial ports using the DIGITAL-LOGIC AG BMP utility. (Note: if you disable the primary port and enable the secondary port, then the secondary port is installed as COM1 by DOS.)
  • Page 19: Floppy Disk Interface

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Serial Port Connectors - COM1, 2, 3, 4 generally Signal Function in/out DB25 Pin DB9 Pin Name Data Carrier Detect Data Set Ready Receive Data Request To Send Transmit Data Clear to Send Data Terminal Ready...
  • Page 20: Speaker Interface

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Only CMOS drives are supported. That means that the termination resistors are 1 Kohm. 5 1/4“-drives are not recommended (TTL interface). The 34 pin Connector: Ribbon 1,27mm IDT dual row terminal with 2.54mm grid The 26 pin Connector: FFC/FPC 0.3mm thick 1.0mm (0.039") pitch (MOLEX 52030 Serie)
  • Page 21: Controllers

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Controllers 4.4.1 Interrupt Controllers An 8259A compatible interrupt controller, within the CS4021 device, provides seven prioritized interrupt levels. Of these, several are normally associated with the board's onboard device interfaces and con- trollers, and several are available on the AT expansion bus.
  • Page 22: Battery Backed Clock (Rtc)

    800 ms. If no strobe occures within the 800 ms, the watchdog resets the system. To program the watchdog in user application DIGITAL-LOGIC AG has implemented a special BIOS ex- tension in Interrupt 60h (function: EBh).
  • Page 23: Bios

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 BIOS 4.6.1 ROM-BIOS Sockets An EPROM socket with 8 Bit wide data access normally contains the board's AT compatible ROM-BIOS. The socket takes any of a 27C010 to 27C040 EPROM (or equivalent) device. The board's wait-state control logic automatically inserts four memory wait states in all CPU accesses to this socket.
  • Page 24: Bios Cmos Setup

    On the next Setup pages (switched with PgDn and PgUp) the values for special parameters are modifi- able. Normally the parameters are set correctly by DIGITAL-LOGIC AG Be very careful in modifying any parameter since the system could crash. Some parameters are dependent on the CPU type. The cache parameter is always available, for example.
  • Page 25: Cmos Setup Harddisk List

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 4.6.4 CMOS Setup Harddisk list Use type 48 or 49 in order to autodetect the harddisk. Press F1 for autoidentify the harddisk parameters. 4.6.5 Larger Harddisks Capacity (> 528Mbytes) Use type 48 and type 49 for user defined harddisk entries.
  • Page 26: Eeprom Saved Cmos Setup

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 4.6.6 EEPROM saved CMOS Setup The EEPROM has different functions, as listed below: • Backup of the CMOS-Setup values. • Storing the keymatrix definitions, if the hardware supports a keymatrix (MSM386SV, MSM386SN, MSM486SV). • Storing system informations like: version, production date, customisation of the board, CPU type.
  • Page 27: Memory

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Memory 4.7.1 Onboard DRAM Memory Speed: 70ns Size: 2 x 72pins SIMM Bits: 36 Bit Capacity: 1 MByte, 4 MBytes, 8 MBytes, 16 MBytes, 32 MBytes, 64 MBytes Bank: 1 and 2 Size combinations Bank1...
  • Page 28: System I/O Map

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 4.7.3 System I/O map The following table shows the detailed listing of the I/O port assignments used in the MICROSPACE MSWS2 board: I/O Address: MSWS2: 0000 - 001Fh DMA controller 1 0020 - 003Fh Interrupt controller 1...
  • Page 29: Vga, Lcd

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 VGA, LCD 4.8.1 VGA / LCD Controller 65540 / 65545 The 65540/45A High Performance VGA Flatpane / CRT controllers provides a powerful, yet versatile, features set of optimized for portable PC requirements. The 65540/45, which integrates the VGA con- troller, industry standard RAMDAC, and monitor sense circuitry, enable a complete VGA sub-system to be implemented with just two chips: CHIPS 65540/45 VGA controller and one memory device.
  • Page 30: Flatpanel Displays

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 4.8.5 Flatpanel Displays The 65540/45 supports all flatpanel display technologies including plasma, electro-luminescent (EL) and liquid crystal displays (LCD). LCD panel interfaces are provided for single panel-single drive (SS), dual panel-single drive (DS) and dual panel dual drive (DD) configurations. A single panel sequences data similar to a CRT (i.e., sequentially from one area of video memory).
  • Page 31: Supported Vga Modes

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 4.8.8 Supported VGA Modes Mode: Type: Colors: CRT: Text: Graphic: DRAM: Monitor: Refresh/HR: Text 40 x 25 320 x 200 256k 70 Hz Text 80 x 25 640 x 200 256k 70 Hz Graphic 40 x 25...
  • Page 32 Sanyo LCM6494-24NAC * just this driver For other possible BIOS’ refer to the Manual Flatpanel Support or contact DIGITAL-LOGIC AG for your personal LCD-BIOS. After selecting the correct flatpanel, please check this by connecting a CRT monitor and powering up.
  • Page 33: Vga Crt/Lcd Display Driver

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 4.8.10 VGA CRT/LCD Display Driver The purpose of the enclosed software drivers is to take advantage of the extended features of the 655XX VGA controller. These capabilities include: Resolutions up to 1024 x 768 in graphics modes with 16 colors...
  • Page 34: Vga Driver Resolutions And File Names

    800 x 600 16, 256 VESA.COM 1024x768 16, 256 VESA.COM On the DIGITAL-LOGIC AG BBS (No. ++41-32 681 53 34) you will find the latest VGA drivers: - 655XXDRI.ZIP - 54X_NT35.ZIP - and others 4.8.10.2 Windows Install Windows as you normally would for a VGA display.
  • Page 35: Description Of The Connectors

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 ESCRIPTION OF THE ONNECTORS Flat cable 44pin IDE is: IDT Terminal for Dual Row (2.00mm grid) and 1.00mm flat cable All others are: IDT Terminal for Dual Row 0.1" (2.54mm grid) and 1.27mm flat cable...
  • Page 36 DIGITAL-LOGIC AG MSWS2 Manual V2.31 IDE interface connector - AT- IDE 2,5" 44 pins RM2.00mm Signal Signal Pin 1 = Reset (active low) Pin 2 = N.C. Pin 3 = D7 Pin 4 = D8 Pin 5 = D6 Pin 6...
  • Page 37 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Floppy disk interface connector for 5,25" and 3,5" FD (34 pins header) Signal Signal Pin 1, = GND Pin 2 = RPM Pin 3 = GND Pin 4 = NC Pin 5 = GND Pin 6...
  • Page 38 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Printerport connector (LPT1) The printer connector provides an interface for 8 bit centronics printers. Header onboard D-SUB connector Signal on the cable Pin 1 Pin 1 = Strobe Pin 3 Pin 2 = Data 0...
  • Page 39 DIGITAL-LOGIC AG MSWS2 Manual V2.31 VGA-LCD connector Signal Function Pin 1 M-Clock Pin 2 Frame Pin 3 Display enable Pin 4 Line pulse Pin 5 Pin 6 Pin 7 VDDSAFE Controled 5 V supply Pin 8 SHFCLK Shift clock Pin 9...
  • Page 40 DIGITAL-LOGIC AG MSWS2 Manual V2.31 For the optional SCSI connector (50pin RM2.54) Signal Signal Pin 2 SCSI data 0 Pin 1 Pin 4 SCSI data 1 Pin 3 Pin 6 SCSI data 2 Pin 5 Pin 8 SCSI data 3...
  • Page 41 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Ethernet RJ45 connector 10BASE-T Signal Pin 1 TX + Pin 2 TX - Pin 3 RX + Pin 4 Pin 5 Pin 6 RX - Pin 7 Pin 8 Utility connector Function Pin 1 PS/2 Mouse Data...
  • Page 42 DIGITAL-LOGIC AG MSWS2 Manual V2.31 DIN 96 pin peripheral connector The numbers in brackets [ ] are the standard pins on the peripheral connector. Speaker output COM1 LPT1 COM3 RS485 line A COM1 LPT1 COM3 RS485 line B COM1 LPT1...
  • Page 43 DIGITAL-LOGIC AG MSWS2 Manual V2.31 AT96 SIEMENS BUS Interface GROUND SBHE IOCHCK RESET MEMCS16 + 5 VOLT LA23 IRQ9 IOCS16 LA22 DRQ2 IRQ10 LA21 IRQ11 Power 12V LA20 GROUND IRQ12 IOCHRDY SMEMW SMEMR IRQ15 LA19 SIOW LA18 SIOR LA17 DACK3...
  • Page 44 DIGITAL-LOGIC AG MSWS2 Manual V2.31 J21/J22 PC/104 BUS Interface Ground Ground IOCHCK Ground SBHE MEMCS16 RESET LA23 IOCS16 LA22 IRQ10 IRQ9 LA21 IRQ11 LA20 IRQ12 DRQ2 LA19 IRQ13 (-12V) LA18 IRQ14 LA17 DACK0 +12V MEMR DRQ0 IOCHRDY Ground MEMW DACK5...
  • Page 45: Jumper Locations On The Board

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 UMPER OCATIONS ON THE OARD The figure shows the location of all the jumper blocks on the MSWS2 board. The numbers shown in this figure are silk screened on the board so that the pins can easily be located. This chapter refers to the individual pins for these jumpers.
  • Page 46: Com Configuration

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 COM Configuration S1CF1 S1CF0 Primary Serial Port Address Disable Disable 3E8H COM3 2F8H COM2 3F8H COM1 S2CF1 S2CF0 Secondary Serial Port Address Disable Disable 2E8H COM4 3F8H COM1 2F8H COM2 Interrupts for COM3 IRQ4 closed...
  • Page 47: Scsi Configuration

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 SCSI Configuration Jumper 34: Base-Address Pin 1-2 Pin 3-4 Function: open open IO-Base 140h open close IO-Base 150h close open IO-Base 160h close close IO-Base 170h * Jumper 34: Interrupt-Number Pin 5 - 6 Pin 7 - 8...
  • Page 48: Information On The Next Few Jumpers

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Information on the next few Jumpers Customers do not have to change these few jumpers. The jumpers have to be set as shown in the handbook illustration. 6.5.1 IDE Harddisk Function The IDE harddisk function is disabled since it’s not possible with this board.
  • Page 49: Jumper Overview

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Jumper Overview RM2.54mm Jumpers LCD Voltage polarity VEE 1-2 = Negative 2-3 = Positive J67 off J68 off J68 on J67 on LAN Adress selection EEPROM Enable 7 - 8 = open always open !
  • Page 50 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Touchscreen configuration PB2 1-2 = VCC 2-3 = GND Touchscreen configuration PB3 1-2 = VCC 2-3 = GND Touchscreen 4/5 wire (seet 4) open HBE LAN Test (seet 4) 2-3 = GND* IDE Mode HD-IOCHRDY...
  • Page 51: Jumper And Connector Locations

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 UMPER AND ONNECTOR LOCATIONS MSWS2 Front View V2.0...
  • Page 52: Msws2 Rear View V2.0

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 MSWS2 Rear View V2.0...
  • Page 53: Cable Interface

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 ABLE NTERFACE The Floppy Disk Cable IDT Terminal for Dual Row 0.1" (2.54 mm grid) and 1.27 mm flat cable Floppydisk Cable 34pin MicroSpace DRIVE B: DRIVE A: max. cable length = 400mm For drive A: the lines 10 to 16 are crossed (180 degrees).
  • Page 54: The Harddisk Cable 40 Pins

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 The Harddisk Cable 40 pins IDT terminal for dual row 0.1" (2.54 mm grid) and 1.27 mm flat cable. 40 pins signal, power is separately wired. Refer to the technical manual of the harddisk used.
  • Page 55: The Harddisk Cable 44 Pins

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 The Harddisk Cable 44 pins IDT Terminal for Dual Row (2.00 mm grid) and 1.00 mm flat cable. 44 pins = 40 pins signal and 4 pins power. Pinspacing=1mm pinspacing 4344 4344 Max. length for IDE cable is 30 cm.
  • Page 56: The Com 1/2 Serial Interface Cable

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 The COM 1/2 Serial Interface Cable DT terminal for dual row 0.1" (2.54 mm grid) and 1.27 mm flat cable Line of pin 1 COM1 9pin D-Sub male COM1/2 ATTENTION: Do not short-circuit these signal lines.
  • Page 57: The Com3/4 Serial Interface (J5)

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 The COM3/4 Serial Interface (J5) Line of pin 1 COM3 9pin D-Sub male COM3/4 COM4 9pin D-Sub male...
  • Page 58: The Printer Interface Cable

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 The Printer Interface Cable IDT terminal for dual row 0.1" (2.54mm grid) and 1.27 mm flat cable Parallelport Cable LPT1 ATTENTION: Maximum length of this cable is 6 meters. Prevent short-circuits. Never apply power to these signals, the MICROSPACE MSWS2 will be destroyed.
  • Page 59: Micro Floppy Interface

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Micro Floppy Interface...
  • Page 60: Software

    IBM: OS/2 V2.0 Application Programs: All software which DIGITAL-LOGIC AG has tested so far, are compatible and run without any problem. BIOS-Variable-Segment Every PC has a memory segment which is reserved for BIOS-variables. The segment starts at the ad- dress of 0040:0000h and ends at the address of 0040:0100h. In the offset of 0A1h to 0FFh is an area reserved which is used in multiple BIOS-extensions and programs.
  • Page 61: Software Tools And Drivers For The Microspace Pc

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Software Tools and Drivers for the MICROSPACE PC The tool disk is divided into the following sub-directories: MSWS2-486 ROMDISK ROMDISK.EXE MAKEROM.DAT TOOLS HD.COM MSWSSET. EXE C&T DOSETUP.EXE VGA tools TOOLS 540SET.COM div. other DRIVERS none, sold separately...
  • Page 62: Supported Lan Drivers

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 Supported LAN Drivers Refer to the DIGITAL-LOGIC AG BBS. ARTWORK.ZIP 109,453 12-14-92 2:32p - SMC9000 Artwork SMC9000H.ZIP 535,043 12-20-94 4:24p - SMC9000 Hardware Design Info SMC9000S.ZIP 452,811 12-20-94 4:23p - SMC9000 Drivers and Utilities NT35OBJ.ZIP 34,577 06-24-94 3:09p - Win NT 3.5 Drivers (also in SMC9000s.zip)
  • Page 63: Required Drivers To Get Windows Nt Lan Support

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 3. There are other proprietary drivers for other operating systems, including „Packet Drivers“ which is a Share-ware type of product. They are supported by the particular operating system vendor, not SMC. A transport stack. There are currently 3 major transport stacks.
  • Page 64: How To Get An Os/2 Workstation To Talk With A Novell Server

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 9.5.5 How to get an OS/2 Workstation to talk with a Novell Server By using NetWare OS/2 V2.0, 2.1 Requester Drivers together with the SMC9000 ODI MAC driver you will achieve that an OS/2 Workstation talks with a Novell Server.
  • Page 65: Special Peripherals, Optional Functions

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 PECIAL ERIPHERALS PTIONAL UNCTIONS 10.1 Special Peripherals 10.1.1 Multifunction Latch The multifunction latch allows control over several functions such as powerdown, contrast and watchdog. This latch can be controlled by the application program. Latch 1:...
  • Page 66: Programmable Contrast, Backlight And Speaker Volume

    This is an important detail! Speaker volume Available only on MICROSPACE Workstation products. There is a third software adjustable potenti- ometer. In order to implement the adjustment of this potentiometer, DIGITAL-LOGIC AG has defined two special functions in the SFI.
  • Page 67: Special Function Interface Sfi, Function Int 60

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.2 Special Function Interface SFI, Function INT 60 SW - INTERRUPT 60H All functions are performed by calling the with the following arguments: 10.2.1 EEPROM Functions: Function: WRITE TO EEPROM Number: EPP-Version: included since version V3.0.
  • Page 68 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Function: ERASE one DATABYTE OF THE EEPROM Number: EPP-Version: included since version V3.0. Description: Erases the selected memory cell of the serial EEPROM. Input Values: AH = Function Request BX = Address of the EEPROM Output Values: none;...
  • Page 69: Adjusting The Contrast, Backlight And The Speaker Volume

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.2.2 Adjusting the Contrast, Backlight and the Speaker volume: Function: INCREMENT POTI Number: EPP-Version: included since version V3.01. Description: Increments the selected potentiometer by 1 step. The new value is stored into the EEPROM of the poti. After power-up the new value is always available.
  • Page 70: Hardware Type Int 60

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.2.3 Hardware type INT 60: Function: HARDWARE TYPE Number: EPP-Version: included since version V3.0. Description: Returns to the MICROSPACE Product code. Input Values: AH = Function Request Output Values: AH = Board Size: M = PC/104 (MSM)
  • Page 71: Harddisk Function

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.2.5 Harddisk function: Function: TURN HARDDISK OFF Number: EPP-Version: included since version V3.10. Description: Turns off the harddisk. The next access to the harddisk will turn on the harddisk automatically. Input Values: AH = Function Request Output Values: none;...
  • Page 72: Ffs-Flash-Functions

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.2.7 FFS-Flash-Functions: Function: PROGRAM THE FLASH Number: EPP-Version: included since version V3.17. Description: Programs the addressed byte of the flash. Input Values: AH = Function Request AL = Databyte BX = Address high word DI =...
  • Page 73: Special Configuration And Options

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.3 Special Configuration and Options 10.3.1 Ethernet IO-Adress and IRQ selection The Ethernet interface is configured with the values stored in an EEPROM. The default values are: Jumper position: 1-2 Configuration: IOS0: IOS1: IOS2: ENEEP: Base-Addr.
  • Page 74: Ethernet Hardware Configuration

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.3.1.1 Ethernet Hardware Configuration The Ethernet controller is hardware selectable with preprogrammed values from the EEPROM. This is the normal way to start with all operating systems and NOS. A. Select the configuration: Selected using the IOS0 - IOS2 jumper.
  • Page 75: Utilities For Programming / Modifying Eeprom And Diagnostics

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.3.1.2 Utilities for programming / modifying EEPROM and DIAGNOSTICS The EEPROM is factory programmed with the default values shown in chapter 3. If the node address should be modified, use a program utility. Use this program to store the standard defaults in the EEPROM: ETHPROG.EXE...
  • Page 76: Ethernet-Drivers

    Windows NT3.1 SMC9000.DLL NDIS3.0 Windows NT3.51 3.51 SMC9000.DLL 0.1A MINIPORT SMCNCDET.DLL 0.1A SMC9000.SYS 0.1A Windows NT4.x load down from the DIGITAL-LOGIC BBS the latest MINIPORT driver OS/2 LAN-Manager 2.01 SMC9000.DOS/OS2 2.01 NDIS2.01 Download the latest drivers from the DIGITAL-LOGIC AG BBS!
  • Page 77: The Flashdisk

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.3.2 The Flashdisk 10.3.2.1 What does a Flash-File-System The Flash-File-System allows you to READ and WRITE information to and from the flashdisk, without limitation. 10.3.2.2 Usable DOS size of a Flash-File-System Depending on the MICROSPACE product, different sizes and types are supported: On the Flashdisk, the real usable capacity must be smaller than the installed devices, due to the spare sector of 64kByte and the memory area used by the FFS.
  • Page 78: The Mini Command.com Processor

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.3.3 The MINI COMMAND.COM Processor The MINI-COMMAND is designed for applications that require only a limited and possibly a tailor-made command processor. The MINI-COMMAND processor contains only the most basic functions of com- mand processing. It requires a minimum of disk / ROM space and can be tailored to a specific hardware platform.
  • Page 79: Touchscreen Driver For Windows

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.3.4.2 Touchscreen driver for Windows COM196 Driver for 9600 Baud on COM1 COM296 Driver for 9600 Baud on COM2 TWCAL.EXE Windows calibration program OEMSETUP.INF Setup data VMD.386 Driver for extended 386 mode TPWIN.DRV Driver for normal mode CALDAT.DAT...
  • Page 80: Scsi - Irq - Number

    The DOS/Windows environment does not support SCSI peripherals directly. The 18C30 SCSI is sup- ported by many SCSI peripherals via device drivers available from Digital-Logic AG. Generally, if your application software is written to either INT12, ASPI, IBM INT 4Bh or CAM it will work with the 18C30 SCSI IC.
  • Page 81: Rs485 On Com3/4

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 10.3.6 RS485 on COM3/4 The RS485 is a factory assembly option. The RS485 may be installed at the place of the RS232C inter- face on the COM3 and/or COM4 interface. The RS485 connection is available only over the 96pin peripheral bus...
  • Page 82: Building A System

    Does the harddisk spindle motor start? Reset the CMOS-RAM: see A.3. C. If the error appears again: Contact your nearest Digital-Logic dealer for technical support Or contact our technical support by Fax ++41 32 681 53 31 (CH) DIGITAL-LOGIC AG, Switzerland...
  • Page 83: Diagnostics

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 IAGNOSTICS 12.1 POD-Error The following numeric codes appear on the system board LEDs (in hex) to report the progress of the power-on diagnostics, or on the LEDs and on the screen (in decimal) to report errors found by the Diag- nostics.
  • Page 84 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Power-on Diagnostics Test Codes LEDs (hex) Meaning Initialize hardware. Initialize timer. DMA init. 8259 init. Initialize Chipset. Set up BMS configuration. Entering Protected Mode for first time. Size memory chips. Configure memory chip interleave. Exiting Protected Mode for first time.
  • Page 85 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Power- on Diagnostics Exception Codes LEDs (hex) Screen (dec) Meaning Exception 0 during POD. Exception 1 during POD. Exception 2 during POD. Exception 3 during POD. Exception 4 during POD. Exception 5 during POD. Exception 6 during POD.
  • Page 86: Index

    DIGITAL-LOGIC AG MSWS2 Manual V2.31 NDEX AT96 SIEMENS BUS Interface ......43 Harddisk cable 40 pins........54 Harddisk cable 44 pins........55 harddisk connected..........18 Harddisk function INT60: ........71 Harddisk list............25 backlight............. 66 Hardware type INT 60 .........70 Backlight INT60..........69 HD.COM.............61 BASE-Address SCSI .......... 79 Battery backed clock (RTC) ........
  • Page 87 DIGITAL-LOGIC AG MSWS2 Manual V2.31 Printerport connector (LPT1) ......38 PS/2 - keyboard connector ........ 38 PS/2 - mouse connector ........38 Termination of the SCSI-BUS ......80 Timer Assignment..........22 tool disk..............61 Touchscreen............78 Touchscreen connector........40 ROM-BIOS............24 Touchscreen driver ..........78 RS485..............20 RS485 on COM3/4 ..........

Table of Contents